Diagrama Da Cummins PDF [PDF]

  • Author / Uploaded
  • Pedro
  • 0 0 0
  • Suka dengan makalah ini dan mengunduhnya? Anda bisa menerbitkan file PDF Anda sendiri secara online secara gratis dalam beberapa menit saja! Sign Up
File loading please wait...
Citation preview

VISIO



6



4



5



2



3



1 REL NO



ECO - 129979



LTR



NO



C



REVISION



DWN CKD



SEE SHT 5



1



TLD



JTB



APVD



DATE



T.AJAYI



25OCT12



D



D



PowerCommand 3.3 FOR KTA38 HYDRO MECHANICAL GENSET PAGE



TITLE



DESCRIPTION



1



INDEX



COVER PAGE



2



WIRING DIAGRAM



SCHEMATIC, ELECTRICAL CONNECTIONS



3



GENSET LOCATION, GENSET



DEVICE LOCATIONS ON GENSET AND HMI



4



LOCATION DIAGRAM, CONTROLS



DEVICE LOCATIONS IN CONTROL BOX



5



OPTIONS



ACCESSORY CONNECTIONS



6



ADDITIONAL PINOUTS



ADDITIONAL PINOUT CONNECTIONS C



C



Notes: 1.



Fusing requirements for Arc flash protection for TB7 (Bus/Utility Voltage Sense)*: If your potential circuits have available incident energy > 1.2 Cal/cm2 or 5J/cm2 then you need to protect for arc flash in the lines feeding TB7**.



Available Incident energy > 1.2 Cal/cm2 or 5J/cm2 is typically found when any of the the following is true:



2.



A)



LL Voltage > 240Vac OR



B)



Paralleled OR



C)



Alternator size > 125kVA



Fusing requirements for Arc flash protection for TB7 (Bus/Utility Voltage Sense)*: If Available Incident energy is > 1.2 Cal/cm2 or 5J/cm2 then the use of current limiting fuses or other suitable means in the lines feeding J22 and TB7** are needed.



The following suggested current limiting fuses will accomplish this:



B



B



A) Fuse rating: 600Vac, 0.5A, AIC=200kA, fast acting, current limiting, Class CC (e.g. Ferraz Shawmut ATMR ½ or equiv.) B) Use 600Vac rejection type fuse holder with AIC=200kA rating, e.g. Ferraz Shawmut 30323R or equiv. C) Fuses must be placed near the voltage source. * Per NFPA 70E and Cummins Electrical Safety Policy. **Fusing protecting the circuit feeding TB7 must also meet all local code requirements. 3.



For enclosure-container wiring diagrams refer to the following drawings. 0630-2941 0630-3613 0630-3080 0630-2867 0630-2868 0630-2873



A



A



UNLESS OTHERWISE SPECIFIED, ALL DIMENSIONS ARE IN MILLIMETERS



.X ` .XX`



ANG TOL: `



6



5



4



3



HOLE



DIM



X `



0.00- 4.99 +0.15/-0.08 5.00- 9.99 +0.20/-0.10 10.00-17.49 +0.25/-0.13 17.50-24.99 +0.30/-0.13 SCALE :



SIM TO



DWN



DO NOT SCALE PRINT



CKD



N_SCHOTTLER



APVD



M_POZO



DATE



01-04-2011



- CONFIDENTIAL -



PROPERTY OF CUMMINS POWER GENERATION



2



CUMMINS POWER GENERATION



N_SCHOTTLER



FOR INTERPRETATION OF DIMENSIONING AND TOLERANCING, SEE ASME Y14.5M-1994



DIAGRAM, SCHEMATIC



SITE CODE FIRST USED ON



KTA38



PGK



DWG SIZE



D



SHEET



A035H705



1



OF



6



DWG REV



C



1



Drawing Name: A035H706 Revision: C Part Name: A035H705 Revision: C Sheet 1 of 7



VISIO



6



REMOTE E-STOP 1B 1A 2B 2A



JUMPER 1



REMOTE E-STOP



1



2



4



3



4



5



JUMPER 2



3A



3B



4A



4B



D



USER INTERFACE



Sw B+ K7



3300 TB1-16



5 J20-11 Starter Disconnect Input 1B 2B



K10-86



PCC3300



E-STOP B+



BASEBOARD



3B



E-STOP



FUSED B+



2



1



P2-7



5



4



6



1



K16-A P21-9 (AUX 105)



RETURN P25-6



P25-2 P25-11



P29-6 RUN (WAKE-UP)



K10-SP



PCC NET SHLD



TB1-4 SEE SHEET 5 TB1-6 SEE SHEET 5



HARNESS, INTERFACE PCC3300-AUX101: A035E359



FUSED B+,4B



2B



P20-18



3B 4B



P20-19



P1-4 P1-5



BARGRAPH



2B BUS L2



P14-1



PART NUMBERS AUX 101: 0327-1536



REMOTE E-STOP 1B



J4-1



3B BUS L3 4B BUS L4



P1-3 PCC NET A (+)



PART NUMBERS HMI 114: 0300-6366-02



W1 SHIELD



HARNESS, INTERFACE PC TOOL TO PCC3300: A040D379



TB7-2 FUSED B+ - 2B



TB7-4



J4-3



5



J4-4



6



J4-5



P1-5 (AUX 101)



A



P12-3 P12-6



1B



SEE SHEET 5



SEE SHEET 5 P10-3, P11-6



SEE SHEET 5 P11-6 SENSE



P10-9, P11-5



P11-5 RETURN



P10-4, P11-8



P11-8 SENSE



P10-10, P11-7



P11-7 RETURN



SEE SHEET 5



SEE SHEET 5



EXHAUST TEMP RIGHT BANK RTD (E7) E7-A E7-B



EXHAUST TEMP LEFT BANK RTD (E6)



SEE SHEET 5



SEE SHEET 5



E6-A



SEE SHEET 5



SEE SHEET 5



E6-B



SEE SHEET 5



SEE SHEET 5



SEE SHEET 5



SEE SHEET 5



SEE SHEET 5



SEE SHEET 5



LEGEND



SEE SHEET 5



OPTIONAL



MODBUS FACTORY CONNECTIONS



J26-6 N/A



D1



J26-7 FIELD CURRENTJ26-8 B+ RETURN HARNESS, ALTERNATING CURRENT: A034Y614



1



3B



2



4B



3



5B



FAST ON CONNECTOR



J26-9 AVR B+



HARNESS, INTERFACE PCC3300 TO AUX 105: A035G905



SET SCREW TERMINAL



J26-14 FIELD CURRENT+ LOW COOLANT TEMPERATURE (S4)



J26-16 AVR PWM+



PLUG CONNECTOR



J26-17 N/A J26-18 KEYSWITCH B+ OUT P26-15



GENSET VOLTAGE P22-1



RING TERMINAL



P26-1 P1939 SHLD



P22-2



P26-10 P1939 (-)



P22-3



G



SEE SHEET 5



J26-5 AVR B+ RETURN P12-1



ALTERNATOR



C SEE SHEET 5 SEE SHEET 5



AUX 101 IS REQUIRED FOR EXHAUST TEMPERTURE SENSING.



P26-2



-



KS



B1-SW1



SEE SHEET 5



B



J26-3 AVR PWM-



P12-4



P26-11 P1939 (+)



P22-4



120 ohm



B



Opens @ 85F, Closes @ 65F



P26-12 PCC NET A (+) P26-13 PCC NET B (-) P26-4 SHLD



AUX 104



V



P21-8 P21-2 P21-3



HM ECM & AVR



U



GOV POWER STAGE



P21-12



AUX 105



TERMINAL BLOCK W



4



TB15-5 WAKE-UP3



TB7-3



P12-5



N



8 9



P12-2



B



7



TB15-4 RS485 B



SEE FUSING REQUIREMENTS ON SHEET 1.



P6-2 B+ RETURN P6-1 HMI FUSED B+



DRIVER RATING S: 4 AMPS PEAK : 6 AMPS +



PC TOOL



K16



TB15-3 RS485 A



P1-4 PCC NET B(-) P1-5 SYSTEM WAKE-UP



P11 P10



CT3



TB7-1 USE PT’s IF LL VOLTAGE >600VAC



KS



CI#4 FUEL LEVEL SWITCH (WAKE-UP)



REMOTE I/O



P14-2 REMOTE E-STOP 2B



TB15-1 GND



1B BUS L1



M



BT2



AUX 101



P1-1



TB1-14 SEE SHEET 5 TB1-15



BUS VOLTAGE



M



CI#12 RUPTURE BASIN SWITCH (WAKE-UP)



P1-2



TB15-5 WAKE-UP3



CT3-6B



HMI 114



KS



KS



B1-SW2



RUPTURE BASIN RETURN



TB1-13 SEE SHEET 5



TB1-16



HARNESS, BUS: A035E847



BT1



B1-BAT



G



P1-3



TB1-11 SEE SHEET 5 TB1-12 SEE SHEET 5



CT2



CT3-5B



G1-D+



ENG SP3



P2-2 P2-4



CT2-4B SP2



P2-9



CUSTOMER INPUTS 1B FUEL LEVEL RETURN



TB1-10 SEE SHEET 5



BUS CURRENT CT1



CT2-3B



COOLANT LEVEL (S7)



Starter 2



Starter 1



GND-ENG



P2-3



TB1-9 SEE SHEET 5



CT1-2B SP1



P28-3 B+ RETURN



B+ RETURN



P2-1



TB1-7 SEE SHEET 5 TB1-8 SEE SHEET 5



P29-3 SYSTEM WAKE-UP BUS CT SHORTING BLOCK CT1-1B



K4+



G1-B+



B1-GND



TB1-2 PCC NET B (-)



P25-8



P28-1 HMI FUSED B+



1B 3B



TB1-3 B+ RETURN TB1-5 CUSTOMER FUSED B+



HARNESS, INTERFACE (PCC3300 TO HMI): A035G075



P25-5



D



TB1-1 PCC NET A (+)



P25-4 SP3



25OCT12



T.AJAYI



P20-8



P25-3



P29-1 PCC NET (+)



DATE



APVD



S2



P20-19



J25-1



P29-2 PCC NET (-)



K4



K4-BAT K4



B1-BAT



P2-8



P20-18



P25-10 J25-7 J25-12 P25-9



S1



G1-GND



P20-12



USE SHIELDED TWISTED PAIR FOR PCC NET ONLY TERMINATE SHIELD ON ONE END



JTB



HEATER CONTROL (P3)



P20-7



P20-6



P25-6



B1-BAT



SHIELD GROUNDED IN FOUR PLACES



P20-1



P29-4 AUTO (CONFIGURABLE WAKE-UP)



X20 (20A)



BATTERY CHARGING ALTERNATOR 24VDC



FSO (K1)



P2-11



GND SIG



TB15-5 WAKE-UP1



P3-B P3-A P3-C



X21 (20A)



B+



P29 must be disconnected to use PC Tools on TB15



B1-BAT



TLD



5B



S7-B S7-D



HARNESS ENGINE: A035H837



X10 (10A)



DWN CKD



-



TB-BAT



S7-C



HARNESS, INTERFACE (WORT BOX): A035H282



-



K9-1



P2-15



SwB+ - 3B B



A



C



4B



HMI-SP1 F-FSO 3A



P20-5



FUSED B+



2B 3B



P20-22



DISPLAY



C



1B



SP4



P2-14 ENG SP4



P20-2 P20-4



TB15-4 RS485 B



PART NUMBERS: HMI 320: 0300-6315-02



K4-S1



INPUT (WAKE-UP ON OPEN) P25-2



PC TOOL



HARNESS, INTERFACE PC TOOL: A035A671



P2-10



ECO - 129979



REVISION



2B



P2-13



FSO K8



P20-20 P20-21



PART NUMBERS PCC3300: 0327-1601



1



NO



J20-11



4



6



P2-6



P-SWB+



LTR



T26



P2-12



P20-17



TB15-1 GND TB15-3 RS485 A



HMI 320



5



P20-9 P20-10



LOCAL E-STOP B+ 4



J20-16 Oil Priming Pump Relay Driver P20-3 P20-15 P20-14



4B GND



3



Starter K9



1 REL NO



3B



S7-B



1



6



P2-5



T26



J20-13 Relay Coil B+ Supply



SW B+



1B



4



3300 TB1-15



REMOVE JUMPERS 1 AND 2 TO INSTALL REMOTE ESTOP



2



3



CT21-1 CT-23



POWERSTAGE



B+ RETURN - 1B



CT21-2/3 CT22-1



P21-6



K10-SP



P21-9



FUSED B+ - 3B



87



85



30



86 E-STOP B+ - 2B



P21-11



PART NUMBERS AUX 105: A028T766



CT23-1 CT-21



J1-5 J1-4 J1-3



P1 - 2 P1-5 GOV PS POWER P1-4 ACT LS DRIVER P1-3 GOV PS POWER



OIL PRESSURE (E1)



K10 KEYSWITCH



CT-22 CT22-2/3



J1-1 J1-2



Part numbers Aux 104: 0327-1507 P1 Mate: 0323-2216 : Sockets: 0323-1200



120 ohm



FUEL ACTUATOR (6AMP MAX) ACT (-) ACT (+)



P1 - 1



E1-B E1-A E1-C



CT23-2/3



P11-5 GOVERNOR PWM + P11-4 GOVERNOR PWM -



XU (.5A)



USE PT’s IF LL VOLTAGE >600VAC



XV (.5A)



MAG PICK-UP (P1) P1-A P1-B



P11-1 +5V P11-2 RETURN



XW (.5A)



P11-3 SENSE COOLANT TEMP LEFT BANK (E2) E2-A



PMG-P2 PMG-P3



P18-2



P11-10 -



PMG-P4



P18-3



P11-11 SENSE P11-12 RETURN



E4-A



P11-13 SENSE



E4-B



AVR CONTROL FIELD (+)



P17-1



FIELD (-)



P17-2



OIL TEMPERATURE (E4)



P11-14 RETURN P11-15 SENSE P11-16 RETURN



UNLESS OTHERWISE SPECIFIED, ALL DIMENSIONS ARE IN MILLIMETERS



PC TOOL



J5-3 J5-4 J5-5



TB15-1 GND TB15-3 RS485 A TB15-4 RS485 B



RS485 SHIELD



X `



COOLANT TEMP RIGHT BANK (E3) HARNESS, INTERFACE PC TOOL: A040G672



E3-A



DIM



J5-1



E3-B



.X `



TB15-5 WAKE-UP



.XX` ANG TOL: `



6



5



A



P11-9 +



PMG



G



E2-B



P11-8 SHIELD



4



3



HOLE



A



AVR POWER P18-1



0.00- 4.99 +0.15/-0.08 5.00- 9.99 +0.20/-0.10 10.00-17.49 +0.25/-0.13 17.50-24.99 +0.30/-0.13 SCALE :



SIM TO



DO NOT SCALE PRINT



- CONFIDENTIAL PROPERTY OF CUMMINS POWER GENERATION



2



DWN CKD



CUMMINS POWER GENERATION



N_SCHOTTLER N_SCHOTTLER



APVD



M_POZO



DATE



01-04-2011



FOR INTERPRETATION OF DIMENSIONING AND TOLERANCING, SEE ASME Y14.5M-1994



DIAGRAM, SCHEMATIC



SITE CODE FIRST USED ON



KTA38



PGK



DWG SIZE



D



SHEET



A035H705



2



OF



6



DWG REV



C



1



Drawing Name: A035H706 Revision: C Part Name: A035H705 Revision: C Sheet 2 of 7



VISIO



6



4



5



2



3



1 REL NO



LTR



NO



C



-



ECO - 129979



REVISION



DWN CKD



-



TLD



JTB



DATE



APVD



25OCT12



T.AJAYI



D



D



COOLANT TEMP RIGHT BANK (E3)



LOW COOLANT TEMPERATURE (S4)



COOLANT TEMP LEFT BANK (E2)



COOLANT LEVEL (S7)



MAG PICKUP (P1) A



C C



C



C A B



B



TB-BAT



K4 T 26



OIL TEMPERATURE (E4)



OIL PRESSURE (E1)



GND ENG



B



B



COOLANT LEVEL (S7)



SEE NOTE 1



HMI 114



HMI 320



- LOW COOLANT LEVEL SENSOR (S7) IS LOCATED AT THE TOP OF THE RADIATOR. - NOT ALL CONNECTION POINTS ARE SHOWN, SEE SPECIFIC HARNESS INSTALLATION DRAWINGS FOR EACH OPTION FOR MORE INFORMATION.



A



A



RADIATOR VIEW



CT-21



CT-23



LOCAL E-STOP DIM



X `



VIEW A-A



VIEW B-B



UNLESS OTHERWISE SPECIFIED, ALL DIMENSIONS ARE IN MILLIMETERS



.X `



5



4



0.00- 4.99 +0.15/-0.08 5.00- 9.99 +0.20/-0.10 10.00-17.49 +0.25/-0.13 17.50-24.99 +0.30/-0.13



.XX` ANG TOL: `



6



HOLE



CT-22



3



SCALE :



SIM TO



DWN



N_SCHOTTLER



DO NOT SCALE PRINT



CKD



N_SCHOTTLER



APVD



M_POZO



DATE



01-04-2011



- CONFIDENTIAL - FOR INTERPRETATION



PROPERTY OF CUMMINS POWER GENERATION



2



OF DIMENSIONING AND TOLERANCING, SEE ASME Y14.5M-1994



CUMMINS POWER GENERATION SITE CODE



FIRST USED ON



KTA38



DIAGRAM, SCHEMATIC DWG SIZE



PGF D



A035H705



SHEET



3



OF



6



DWG REV



C



1



Drawing Name: A035H706 Revision: C Part Name: A035H705 Revision: C Sheet 3 of 7



VISIO



6



4



5



2



3



1 REL NO



LTR



NO



ECO - 129979



C



-



REVISION



DWN CKD



-



TLD



JTB



APVD



DATE



T.AJAYI



25OCT12



D



C



SWITCH (WAKE-UP)



CI#12 RUPTURE BASIN



MODBUS



SWITCH (WAKE-UP)



K16



CI#4 FUEL LEVEL



D



REMOTE E-STOP



K22



E-STOP B+



1 A



2 A



3 4 A A



5 A



1 A



2 A



3 4 A A



1 A



2 A



3 4 A A



1 A



2 A



3 4 A A



1 A



2 A



3 4 A A



5 A



1 A



2 3 A A



4 5 A A



1 A



2 A



3 4 A A



5 A



1 B



2 B



3 4 B B



5 B



1 B



2 B



3 4 B B



1 B



2 B



3 4 B B



1 B



2 B



3 4 B B



1 B



2 B



3 4 B B



5 B



1 B



2 3 B B



4 5 B B



1 B



2 B



3 4 B B



5 B



BUS CT SHORTING BLOCK



K17



OPTIONAL RELAYS 6X (K13,K14,K15,K19,K20,K21)



B+ RETURN



SW B+



FUSED B+



FAT (2A)



K18



K23



F-FSO (3A)



1A



2A



3A



4A



5A



6A



HEATER POWER



A



1 A



B



1 2 3 4 5 B B B B B L L L/N L/N G 1B



2B



3B



4B



5B



2 A



3 4 A A



BUS VOLTAGE 5 A



1 A



2 A



3 A



4 A



1 2 3 4 B B B B L1 L2 L3 N



C



6B



AUX 104



TB8



TB1 K7



K8



J18



K9



TB3



J 1



TB5



TB10 J14



J26



J25 TB 15



J4



J3



J 11



J20 J21 J2



J11



TB 15 J14



A



CT2



CT3



J1



TB7



J22



DIM



X `



VIEW C-C



UNLESS OTHERWISE SPECIFIED, ALL DIMENSIONS ARE IN MILLIMETERS



.X ` .XX`



ANG TOL: `



4



A



3300



AUX 105



5



CT1



J12



AC WIRE ENTRANCE



AUX 101



6



B



TB 9



3



HOLE



B



DC WIRE ENTRANCE



J17



J 10



0.00- 4.99 +0.15/-0.08 5.00- 9.99 +0.20/-0.10 10.00-17.49 +0.25/-0.13 17.50-24.99 +0.30/-0.13 SCALE :



SIM TO



DWN



DO NOT SCALE PRINT



CKD



N_SCHOTTLER



APVD



M_POZO



DATE



01-04-2011



- CONFIDENTIAL - FOR INTERPRETATION



PROPERTY OF CUMMINS POWER GENERATION



2



CUMMINS POWER GENERATION



N_SCHOTTLER



OF DIMENSIONING AND TOLERANCING, SEE ASME Y14.5M-1994



SITE CODE FIRST USED ON



KTA38



DIAGRAM, SCHEMATIC DWG SIZE



PGK D



A035H705



SHEET



4



OF



6



DWG REV



C



1



Drawing Name: A035H706 Revision: C Part Name: A035H705 Revision: C Sheet 4 of 7



VISIO



6



4



5



2



3



1 REL NO



ECO - 129979



LTR



NO



C



1



REVISION REMOVE TB10-5 B+ AND TB10-10 GND CONNECTIONS, ADD B+ RETURN -2B AND FUSED B+ -1A (ZONE D-5)



DWN CKD



APVD



DATE



TLD



T.AJAYI



25OCT12



JTB



PARALLELING CIRCUIT BREAKER RELAY CONTROL



OPTIONAL RELAYS PCC 3300 TB1 13



21



43



43



A2



14



22



44



44



ALARM RELAY K21



RTD CONNECTIONS ALARM MODULE FUSED B+ -1A



D



PCC 3300 TB1



TB1-5



B+



K19



TB1-6 TB1-8 TB1-9



A1



13



21



43



43



A2



14



22



44



44



CONFIGURABLE RELAY K13



A1



13



21



43



43



A2



14



22



44



44



J22-4 (N)



PCC 3300 TB8



A1



13



21



43



43



A2



14



22



44



44



TB1-5



B+



J2-



TB1-8



A1



13



21



43



43



A2



14



22



44



44



CONFIGURABLE RELAY K15



RED



FAT (2A)



RED WHITE



PCC 3300 TB8-7



A1



CIRCUIT BREAKER TRIPPED



K18 (TEMPERATURE MONITORING)



PC3300 TB10



A2



16



18



26



28



25



13



21



43



43



A2



14



22



44



44



TB10-2



TB1-10



GND



W2



RED WHITE



TB1-9



A1



RTD



RED 15 Tb



Generator Circuit Breaker



RTD



RED



SDE Contact



V2



RED



K17 (DELAYED MAKE)



RTD



WHITE RED



CLOSE STATUS OUTPUT



TB5



U2



RED WHITE



PCC 3300 TB8-12



RTD



RED



TB8-9



W1



RED WHITE



OPEN STATUS OUTPUT



TB8-10



N.D.E BEARING D.E BEARING



RED WHITE



R



PTC Ta



RTD



RED



J1+



CONFIGURABLE RELAY K14 K20



J22-3 (W)



D



WHITE



K17 (TIMER 0-10SEC)



AUDIBLE ALARM MODULE



B+ RETURN -2B



TB1-10



GND



THERMISTOR RELAY



RESET



A1



TB10-10



RTD



RED



C ALT. TEMP THERMISTORS



C



V1



RED WHITE



RTD



RED



U1



RED



RTD



HEATERS (COOLANT, CONTROL BOX, ALTERNATOR) HEATER CONTROL BOX Fuel Level



GROUND FAULT RELAY PCC 3300 TB8



B+ RETURN - 2B



RHI1 RHI1



High level warning



HT2



5



3



8



6



4



1



B



K22 RH99M



PCC 3300 TB1-13



BATT -VE (B+ RETURN)



- WIRING DIAGRAMS SHOWN ON THIS SHEET ARE GENERALIZED, SEE SPECIFIC INSTALLATION DRAWINGS FOR EACH OPTION FOR MORE INFORMATION.



TB8-13 Low Fuel warning



TB1-12



HE2



SHUNT TRIP



Customer Inputs Terminal block 1A



2A



3A



4A



1B



2B



3B



4B



RESET



CONTROL BOX HEATER



Low Fuel Shutdown 1A



2A



3A



4A



5A



1B



2B



3B



4B



5B



ALTERNATOR HEATER Ground Fault Relay is available on single set applications only.



A



14



32 31 34 25 26 27 11



ST-1 ST-2



TEST



TB1-13



ON (RELAY OPERATIONAL)



BATT +VE (SW B+) HE1



T2



PCC 3300 TB1-14 TB8-8



K23



HT1



T1



A1 A2



90



126



E



255



254



253



252



250



N



L



E



CT3



PCC 3300 TB1



FUSE1 4A



B



CT1



Fused B+ - 1A



A



HP HA UNLESS OTHERWISE SPECIFIED, ALL DIMENSIONS ARE IN MILLIMETERS



.X ` .XX`



ANG TOL: `



6



5



4



3



HOLE



DIM



X `



0.00- 4.99 +0.15/-0.08 5.00- 9.99 +0.20/-0.10 10.00-17.49 +0.25/-0.13 17.50-24.99 +0.30/-0.13 SCALE :



SIM TO



DO NOT SCALE PRINT



- CONFIDENTIAL PROPERTY OF CUMMINS POWER GENERATION



2



DWN



CUMMINS POWER GENERATION



N_SCHOTTLER



CKD



N_SCHOTTLER



APVD



M_POZO



DATE



01-04-2011



FOR INTERPRETATION OF DIMENSIONING AND TOLERANCING, SEE ASME Y14.5M-1994



DIAGRAM, SCHEMATIC



SITE CODE FIRST USED ON



KTA38



PGK



DWG SIZE



D



SHEET



A035H705



5



OF



6



DWG REV



C



1



Drawing Name: A035H706 Revision: C Part Name: A035H705 Revision: C Sheet 5 of 7



VISIO



6



PCC3300 BASEBOARD PART NUMBERS PCC3300: 0327-1601



4



5



2



3



1 REL NO



LTR



NO



ECO - 129979



C



-



REVISION



DWN CKD



-



TLD



JTB



APVD



DATE



T.AJAYI



25OCT12



TB1-1 PCC NET A (+) SEE SHEET 2 TB1-2 PCC NET B (-) SEE SHEET 2



PCC3300



TB1-3 B+ RETURN SEE SHEET 2 TB1-5 CUSTOMER FUSED B+ SEE SHEET 2 TB1-4 CONFIGURABLE O/P #5



BASEBOARD



AUX 101 REMOTE I/O



PART NUMBERS PCC3300: 0327-1601



TB1-6 CONFIGURABLE O/P #1-A



D



J2-1 RELAY 1 NO



TB1-7 CONFIGURABLE O/P #1-B TB1-8 CONFIGURABLE O/P #2-A



TB8-1 DISCRETE INPUT RETURN



J2-2 RELAY 1 COM



TB8-2 DISCRETE INPUT RETURN



J2-3 RELAY 1 NC



TB1-9 CONFIGURABLE O/P #2-B



TB8-3 DELAYED OFF RELAY DRIVER



J2-4 RELAY 2 NO



TB1-10 REMOTE START RETURN



TB8-4 SWITCHED B+ RELAY DRIVER



J2-5 RELAY 2 COM



TB1-11 REMOTE START TB1-12 CONFIGURABLE I/P #1



TB8-5 REMOTE FAULT RESET TB8-6 START TYPE



J2-7 RELAY 3 NO



TB1-13 RETURN TB1-14 CONFIGURABLE I/P #2



TB8-7 CONFIGURABLE INPUT #13



J2-8 RELAY 3 COM



TB8-8 CONFIGURABLE INPUT #14



J2-9 RELAY 3 NC



TB1-15 REMOTE E-STOP SEE SHEET 2 TB1-16 REMOTE E-STOP SEE SHEET 2



TB8-9 CONFIGURABLE OUTPUT #4



J2-10 RELAY 4 NO



TB8-10 CONFIGURABLE OUTPUT #3



J2-11 RELAY 4 COM



TB8-11 LOAD DUMP RELAY DRIVER



J2-12 RELAY 4 NC



J2-6 RELAY 2 NC



TB8-12 DISCRETE INPUT RETURN TB3-1 RETURN



TB8-13 DISCRETE INPUT RETURN



TB3-2 MASTER CAN SHIELD



J3-1 RELAY 5 NO



TB3-3 MASTER CAN L



J3-2 RELAY 5 COM



TB3-4 MASTER CAN H



J3-3 RELAY 5 NC



TB3-5 CONFIGURABLE OUPUT #20 STATUS TB3-6 CONFIGURABLE OUPUT #21 STATUS TB3-7 SPARE OUTPUT FOR FURTURE USE TB3-8 CONFIGURABLE OUPUT #22 STATUS



TB9-1 KW LOAD SETPOINT



J3-4 RELAY 6 NO



TB9-2 ANALOG RETURN



J3-5 RELAY 6 COM



TB9-3 KVAR LOAD SETPOINT



J3-6 RELAY 6 NC



C



TB9-4 VOLTAGE BIAS OUTPUT / CONFIGURABLE ANALOGY OUTPUT #2 OUTPUT PREDICTOR



TB3-9 TRANSFER INHIBIT/CONFIGURABLE INPUT #20 SWITCH



TB9-5 SPEED BIAS OUTPUT / CONFIGURABLE ANALOG OUTPUT #1 OUTPUT PREDICTOR



TB3-10 RETRANSFER INHIBIT/CONFIGURABLE INPUT #21 SWITCH TB3-11 MASTER FIRST START STATUS TB3-12 RETURN



TB9-6 ANALOGY RETURN



J4-1 RELAY 7 NO



TB9-7 KW LOAD SHARE LEVEL TB9-8 NOT USED



J4-2 RELAY 7 COM J4-3 RELAY 7 NC



TB9-9 LOAD SHARE SHIELD



J4-4 RELAY 8 NO



TB5-1 GENSET CB CLOSE STATUS



TB9-10 + KVAR LOAD SHARE LEVEL



J4-5 RELAY 8 COM



TB5-2 GENSET CB CLOSE STATUS



TB9-11 - KVAR LOAD SHARE LEVEL



J4-6 RELAY 8 NC



TB5-3 GENSET CB OPEN STATUS TB5-4 GENSET CB OPEN STATUS



J10-1 CAN H



TB5-5 GENSET CB OPEN STATUS



J10-2 CAN L



TB5-6 UTILITY CB CLOSE STATUS



J10-3 INPUT #3 CURRENT SOURCE (SEE SHEET 2)



TB5-7 UTILITY CB CLOSE STATUS



J10-4 INPUT #4 CURRENT SOURCE (SEE SHEET 2)



TB5-8 UTILITY CB OPEN STATUS



TB10-1 RETURN



TB5-9 UTILITY CB OPEN STATUS



TB10-2 RETURN



J10-5 INPUT #5 CURRENT SOURCE J10-6 INPUT #6 CURRENT SOURCE



TB10-3 UTILITY CB POS A SWITCH



J10-7 5VDC SUPPLY #1 (20 mA MAX)



TB10-4 UTILITY CB POS B/CONFIGURABLE INPUT #23 SWITCH



J10-8 5VDC SUPPLY #2 (20 mA MAX)



TB10-5 UTILITY CB TRIPPED SWITCH



J10-9 INPUT #3 CURRENT RETURN (SEE SHEET 2)



TB10-6 UTILITY CB INHIBIT/CONFIGURABLE INPUT #25 SWITCH



J10-10 INPUT #4 CURRENT RETURN (SEE SHEET 2)



TB10-7 GENSET CB POS A SWITCH



J10-11 INPUT #5 CURRENT RETURN



TB10-8 GENSET CB POS B/CONFIGURABLE INPUT #26 SWITCH



B



J10-12 INPUT #6 CURRENT RETURN



TB10-9 RETURN TB10-10 GENSET CB TRIPPED SWITCH TB10-11 GENSET CB INHIBIT/CONFIGURABLE INPUT #28 SWITCH



J11-1 INPUT #1 RETURN



TB10-12 UTILITY SINGLE MODE VERIFY/CONFIGURABLE INPUT #29 SWITCH TB10-13 SYNC ENABLE/CONFIGURABLE INPUT #28 SWITCH



J11-2 INPUT #1 SENSE J11-3 INPUT #2 RETURN



TB10-14 LOAD DEMAND STOP CONFIGURABLE I/P#31



J11-4 INPUT #2 SENSE



TB10-15 RAMP LOAD/UNLOAD CONFIGURABLE I/P#32



J11-5 INPUT #3 SENSE RETURN (SEE SHEET 2)



TB10-16 RETURN



J11-6 INPUT #3 SENSE (SEE SHEET 2)



TB10-17 RETURN



J11-7 INPUT #4 SENSE RETURN (SEE SHEET 2) J11-8 INPUT #4 SENSE (SEE SHEET 2) J11-9 INPUT #5 SENSE RETURN J11-10 INPUT #5 SENSE J11-11 INPUT #6 SENSE RETURN J11-12 INPUT #6 SENSE J11-13 INPUT #7 RETURN J11-14 INPUT #8 SENSE (ANALOG 0-38VDC) J11-15 INPUT #8 RETURN J11-16 INPUT #8 SENSE (ANALOG 0-38VDC)



A



A



UNLESS OTHERWISE SPECIFIED, ALL DIMENSIONS ARE IN MILLIMETERS



.X ` .XX`



ANG TOL: `



6



5



4



3



HOLE



DIM



X `



0.00- 4.99 +0.15/-0.08 5.00- 9.99 +0.20/-0.10 10.00-17.49 +0.25/-0.13 17.50-24.99 +0.30/-0.13 SCALE :



SIM TO



DO NOT SCALE PRINT



- CONFIDENTIAL PROPERTY OF CUMMINS POWER GENERATION



2



DWN



CUMMINS POWER GENERATION



N_SCHOTTLER



CKD



N_SCHOTTLER



APVD



M_POZO



DATE



01-04-2011



FOR INTERPRETATION OF DIMENSIONING AND TOLERANCING, SEE ASME Y14.5M-1994



DIAGRAM, SCHEMATIC



SITE CODE FIRST USED ON



KTA38



PGK



DWG SIZE



D



SHEET



A035H705



6



OF



6



DWG REV



C



1



Drawing Name: A035H706 Revision: C Part Name: A035H705 Revision: C Sheet 6 of 7



Part A035H705 C Description



Legacy Name



External Regulations



Application Status



Release Phase Code



Security Classification



DIAGRAM,SCHEMATIC



A035H705



None



Production & Service



Production



Proprietary



Alternates



Part Specifications :A035H705 C Name



Description



A030B356



SPECIFICATION,MATERIAL



Legacy Name CES10903



A035H706



DRAWING,ENGINEERING



A035H706



Drawing Name: A035H706 Revision: C Part Name: A035H705 Revision: C Sheet 7 of 7