14 0 639 KB
s
Data Sheet
Mammomat Select Makes your day the easy way
www.siemens.com/select
Mammomat Select Makes your day the easy way
With more than 30 years experience, Siemens is one of the leaders in mammography systems. Mammomat Select is our analog mammography system designed to make your day the easy way. Our proven expertise in mammography has now been enhanced with smart features.
Fully motorized system movements enable quick positioning – at the touch of a button
Personalized OpDose with AEC individually selects the right dose for every woman
Easy to touch screen Features like EasyTouch and isocentric rotation allow you to streamline your workflow. Easy to dose right Personalized OpDose with Automatic Exposure Control makes individually selecting the right dose for each woman very simple.
Seamless isocentric rotation enables rapid positioning for the next view without changing detector height
Easy to invest low Mammomat Select comes with an affordable price tag, low service costs and enables high patient throughput.
Compact installation and reduced space requirements thanks to integrated generator
* Option
Tube with anode-filter combination lets you choose between a Mo/Mo or Mo/Rh combination*
Flexible configuration with an 18 x 24 cm or 24 x 30 cm bucky table as well as magnification, spot and 2D biopsy options
EasyTouch allows easy operation at the touch of a button
System specification
Mammomat Select
System specification
Page
4– 5
Accessories
Page
6
Room planning
Page
7–9
X-ray stand Height adjustment (motorized)
75 cm to 133 cm
Swivel range (motorized)
– 135° to + 180°
Source-to-Image distance (SID)
65 cm
Compression
3 kg to 20 kg
Magnification factors*
1.8, geometric
Grid
Reciprocating, grid ratio 5:1, 41 lines/cm
Radiation shield*
0.3 mm lead equivalent lead glass
X-ray generator
4
Microprocessor-controlled high-frequency generator
40 kHz
Power output
3.3 kW (IEC 60601-1)
kV range
23 kV to 35 kV (adjustable in 1 kV increments)
mAs range
10 mAs to 600 mAs in manual mode (large focus)
10 mAs to 180 mAs in manual mode (small focus)
6 mAs to 600 mAs in AEC mode (large focus)
2 mAs to 180 mAs in AEC mode (small focus)
Exposure times, automatic
70 ms to 6 s (large focus)
70 ms to 6 s (small focus)
Exposure times, manual
0.1 s to 6 s (large focus)
0.3 s to 6 s (small focus)
* Option
System specification
Mammomat Select
X-ray tube Mammography X-ray tube unit with molybdenum rotating anode tube Nominal anode input power
4.8 kW (large focus) (IEC 601-2-28)
1.15 kW (small focus) (IEC 601-2-28)
Focal spot nominal value
0.1 / 0.3 (IEC 336, EN 60336)
Maximum tube current
100 mA at 25 kV (large focus)
28 mA at 25 kV (small focus)
Maximum continuous heat dissipation
80 W (IEC 601-2-28)
Nominal voltage
40 kV
Heat storage capacity (tube unit)
320 kJ (416 kHu)
Heat storage capacity (anode)
225 kJ (300 kHu)
Optical anode angle
15°
Inherent filtration
0.5 mm Be
Anode speed
3000 rpm
Automatic exposure control (AEC) Microprocessor-controlled, with transparency compensation AEC detector
Semiconductor detector based
Accuracy of optical desity
± 0.15 O.D.
Density correction range
> 1.0 O.D.
Density correction step
0.05 O.D. to 0.2 O.D.
Biopsy* 2D biopsy
* Option
Biopsy hole plate
5
Accessories
Mammomat Select
Overview of Options Compression plates
Compression plate with low edge, 18 cm x 24 cm
Compression plate with high edge, 18 cm x 24 cm
Compression plate with low edge, 24 cm x 30 cm
Compression plate with high edge, 24 cm x 30 cm
Detail / spot compression plate
Axilla compression plate, 8 cm x 20 cm
Perforated biopsy compression plate
Object tables
Object table with Bucky 18 cm x 24 cm
Object table with Bucky 24 cm x 30 cm
Magnification Attachment
Magnification table 1.8 with paddles
Radiation shield
Free-standing radiation shield consisting of a frame and 0.3 mm lead equivalent lead glass with holder for control console
Data transfer and documentation
Interface for CR integration
Interface for Triacon ID network camera
External power unit
6
* Option
External power unit for 110V, 120V, 130V, 208V, 230V and 240V single-phase power types
Room planning
Mammomat Select
Operating data Power requirements
110 V, 120 V, 130 V, 208 V, 220 V, 230 V and 240 V AC < 0.6 Ohm, ± 10 %, single-phase, 50/60 Hz ± 1 Hz
For 110 V, 120 V, 130 V, 208 V, 230 V,and 240 V external power unit is needed
Power capacity
5 kVA
Weight Examination stand and generator
350 kg
Control desk with radiation shield
46 kg
7
Room planning
Mammomat Select
Environmental conditions Operation Temperature range
+ 10 ºC to + 40 ºC
Relative humidity
30 % to 75 %, non-condensing
Atmospheric pressure
700 hPa to 1060 hPa
Transport / storage
8
Temperature range
– 20 °C to + 70 °C
Relative humidity
10 % to 90 %
Barometric pressure
700 hPa to 1060 hPa
Room planning
Mammomat Select
Dimensions in cm
9
On account of certain regional limitations of sales rights and service availability, we cannot guarantee that all products/ services/features included in this brochure are available through the Siemens sales organization worldwide. Availability and packaging may vary by country and are subject to change without prior notice. The information in this document contains general descriptions of the technical options available and may not always apply in individual cases. Siemens reserves the right to modify the design and specifications contained herein without prior notice. Please contact your local Siemens sales representative for the most current information.
In the interest of complying with legal requirements concerning the environmental compatibility of our products (protection of natural resources and waste conservation), we may recycle certain components where legally permissible. For recycled components we use the same extensive quality assurance measures as for factory-new components. Any technical data contained in this document may vary within defined tolerances. Original images always lose a certain amount of detail when reproduced. This product does not yet have a certificate of conformity. Mammomat Select 144 32 283
Global Business Unit Address
EU Authorized Representative
Siemens AG Medical Solutions X-Ray Products Henkestraße 127 DE-91052 Erlangen Phone +49 9131 84-0
Siemens AG Medical Solutions Henkestraße 127 91052 Erlangen Germany
Global Siemens Headquarters Siemens AG Wittelsbacherplatz 2 80333 Muenchen Germany
Global Siemens Healthcare Headquarters Siemens AG Healthcare Sector Henkestraße 127 91052 Erlangen Germany Phone +49 9131 84-0 www.siemens.com/healthcare
Legal Manufacturer Siemens Shanghai Medical Equipment Ltd. No. 278, Zhouzhu Road Shanghai, 201318 P. R. China
Order No. A91XP-30015-1T1-7600 | Printed in Germany | H CP XP MK 0814pdf | © 08.2014 Siemens AG
www.siemens.com/healthcare