Preface Thank you using M8500/M8600 series frequency actuator. Please reading carefully this manual before installing and adjusting.
■Precautions about this user user’’s manual (1)This manual shall be delivered to end-users. Please take care and keep it properly. (2)Read this user’s manual carefully to fully understand operation method of this product before operation. (3)Don’t extract or replicate part or all contents of this manual without authorization. (4)This manual will be changed without any previous notice. (5)When compiling this manual, we do our best to ensure its accuracy. If user finds any mistake or pretermission, please contact our marketing dept.
■Precautions about safe operation (1)In order to protect and ensure safety of the system controlled by this product, when using, abiding by instructions and precautions related to safety in this manual strictly. Our company will not be responsible for any consequence resulted from it. (2)If any individual protecting device or safe circuit is equipped on the system controlled by this product, please mount these circuits outside this product. Don’t change or mount the circuits inside this product. (3)When changing parts or expendables of this product, please use products recommended by our company.
■Exempt responsibility about this product (1)Unless otherwise specified in warranty provided by our company, we have no guarantee for these products. (2)During direct or indirect use of these products, we will not compensate for any damage of the party concerned caused by unforeseeable defects.
■Special cautions (1)After the installation is complete, Oil plug on the highest place of actuator must be changed with air plug provided in list of spare parts! (2) Cable wire must drill through exceed cover of supplied in the spare part and spin tightly. (3)Installation/debugging process and after the completion, screw in outgoing line cover must be screwed tightly! Intensity advice connects with shield lead. User caused loss for failure to observe the installation of the product product’’s requirements, our company shall not bear responsibility for the warranty.
1
Unpacking check, Transportation, Storage and safe notes 1.1 Unpacking check Each actuator was checked strictly before leaving factory to ensure quality of product. After unpacking the actuator, please carry out the following checks immediately. (1)Check whether actuator is damaged during transportation; (2)Check whether the actuator and attachment is the same as packing list, model of ordered contract.
1.2 Transportation and storage (1)Transportation temperature is -30℃~+75℃ Storage temperature is -10℃~+45℃; (2)Under the condition without special package, place it in dry room to avoid condensation; (3)During transporting it in humid environment with corrosive gas, it must have suitable packing and desiccant. Check whether the desiccant is valid.
1.3 Safe precautions Actuator is a special device to drive terminal control cell (valve and baffle), which has be widely used in the industries such as electric power, metallurgic, petroleum, chemical, building material, urban water supply and sewage treatment etc. Notes when installing: (1)When operating actuator under high temperature environment, operator must wear special protective glove to avoid personal injury resulted from heating of metal parts. (2)According to design purpose, driving baffle and valve unit of actuator is in rotary motion. It is dangerous for operator to operate improperly. (3)Leaked lubricant during change of oil shall be cleaned up timely to avoid accident. Waste oil shall be timely treated by operator on the site to avoid pollution of water source. (4)Mounting, configuration setting and electric connection of actuator must be carried out by experienced professionals. (5)Operators must observe security operating procedures when operating. First cutting power, then operating electric parts, we should prevent hasty drive actuators because of the operator’s negligence.
2
Contents Chapter 1: Overview Chapter 2: Exceed factory state 2.1 Degree of protection 2.2Standard configure
Chapter 3: Structure and principle 3.1Collectivity structure and principle 3.2Structure of electric parts and principle 3.3Additional gearbox
Chapter 4: Technique parameter 4.1Currency data
Chapter 5: Lubricate 5.1 Actuator 5.2 lube 5.3 Additional gear-box 5.4 Assistant output module(A mode)
Chapter 6: Installing 6.1 The inspect of actuator 6.2 Installing notes
Chapter 7: Electric connection 7.1 Connection 7.2 Line diameter choice( contact connection) 7.3 Safety
Chapter 8: Parameter setting and faceplate operation 8.1 By the operation and adjustment of control board. 8.2 Save setup
Chapter 9: Alarm and trouble 9.1 Alarm 9.2 Alarm information 9.3 Trouble 9.4 Trouble information
Chapter 10 10:: Actuator outline and installation dimension Chapter 11 11:: Lever mode additional reducer 11.1 Technical date 11.2Universal parameter 11.3 Outline and structure dimension of reducer
Chapter 12 12:: Linear mode additional reducer 12.1 Technical data 12.2 Outline and installation dimension of linear mode additional reducer 3
Chapter 13 13:: Multi-turn additional reducer 13.1 Technical date 13.2 Outline and installation dimension of lever mode additional reducer
1 Overview M8500/M8600 series conversion-frequency actuator is professional equipment for driving unit of terminal control (value, baffle and so on). The product is a new generation of built-in DSP engine of high-performance 16-bit single-chip (DSPIC digital signals, simple called DSC DSC) of the United states Microchip Technology Inc. at the core. It adopts frequency control technique with contemporary advanced to realize ideal mild start and orientation control. And it has reduced machine impact. I t has a series of self-diagnose and self-protect function for over torque and over heat. It has excellent protect effect to terminal adjusted unit of value. It adopts conversion-frequency control, which can flexible adjustment for output thrust (torque) during orientation process to realize high-precision orientation and without over rush. Its start-current approach motor’s rating current, which is start-current of routine switch control for one-eight to one-fourth and reduce strike for this produce’s driving part and motor. It has high-reliability. According to user’s request, this product has infrared communication function or according to Fieldbus communication function of profibus-DPV1 protocol. It realizes digital communication control, fast setup, remote operation, trouble diagnoses and information collection. This produce widely applies to electricity, metallurgy, oil, chemicals, building materials, urban water supply, sewage treatment, and other industries with high control requirements of the occasion.
2 Exceed factory state 2. Exceed factory state 2.1 Grade of protect The protection degree is IP65 when the actuator was supplied. After installing cable’s sealed stuff and cable wire, it can ensure to reach IP67grade of protect.
2.2 Standard configuring If you haven’t other especially illuminate, the standard configuring of the intelligent conversion-frequency see table 1. Table 1 Standard configuring Function
Function description and parameter
Language display
English
Cutting-off torque
40%(Two directions)
Speed (rpm)
40%( Two directions)
According to position cutting-off
100%(+)
Running mode
Spot act
Digital input 1
The actuator open
Digital input 2
The actuator close
Digital input 3
Remote analog control/remote discrete signal control switch
Digital input 4
Remote discrete signal, momentary and stop midway.
Analog input
4mA~20mA(M8600 series actuator be configured,M8500series actuators don’t be configured)
0%(-)
4
Analog output
4mA~20mA
Digital input A1
Trouble alarm, when there is failure or external power cutting, the terminal of 1-3 connect, the terminal of 1-2 cut off. It's opposite if no trouble.
Digital input A2
Event alarm output. When alarm, the terminal of 4-5 connect, the terminal of 4-6 cut off. Otherwise opposition.
Digital input A3
When the actuator is in full opening position±1%,the terminal of 7-8 is connection. When the actuator in the other position, the terminal of 7-8 is cut.
Digital input A4
When the actuator is in full closing position±1%,the terminal of 9-10 is connection. When the actuator in the other position, the terminal of 9-10 is cut.
Digital input A5
Digital input A6
Digital input A7
Opening over torque alarm. When alarm, the terminal of 25-26 is connection, the terminal of 25-27 is cut. Otherwise opposition. Closing over torque alarm. When alarm, the terminal of 28-29 is connection, the terminal of 28-30 is cut. Otherwise opposition. When remote working, the terminal of 31-32 is cut, otherwise the terminal of 31-32 is connection.
Fig.1 Main parts (Cutaway view)
3 Structure and principle 3.1Collectivity structure and principle The actuator is by the composition of the conversion-frequency motor, position sensor, worm wheel, worm, driving shaft, control unit, local operation panel, hand-wheel. The control unit accepts 4~20mA or discrete control signal and driving motor’s turning. The motor drives worm which driving worm wheel again to drive output shaft turning. The position sensor checks position of motor’s turning and transmit position of value to control board. When the control board checks that the position signal and given control signal is the same as position appointed, cutting motor’s power, the self-lock character of the worm and worm wheel make the actuator stop running.
3.2 Structure of electric parts and principle 5
The electrical parts mainly involve connection terminal board, power filtering board, CPU board, conversion-frequency board, hall sensor board and so on. The connection terminal board affords outside connection which involve in/out terminal of control signal, power terminal, lithium battery and connection terminal, battery switch and so on. They locate in connection terminal box. The power filtering board locates in operation faceplate-cover. It makes up of power filtering, fuser and resistance/capacitance filtering network which fulfill power filtering to realize EMI protect. Main power enter into connection terminal by power filtering board outputting to conversion-frequency which supply power for the device. The CPU board and signal board locate inside operation faceplate-cover and signal board locate in the back of CPU CPU. The switch-box’s knobs on the button of operation faceplate operate by magnetism part effecting into magnetic switch. They realize operation and control without contact. The CPU board mainly makes up of micro-controller, digital analog input/output channels, operation switch, display and so on, which is control core in the device. The analog adjustment signal inputs to the CPU by the signal board. The feedback signal fulfills D/A switch by the CPU board and outputs direction volts d.c. into the signal board. The signal board fulfills photo-electricity separation and V/A switch, which output to up-system. After the displacement of output shaft has been checked by the hall sensor, it outputs pulse signal into the CPU board and fulfills count and switch. The discrete signal outputs the relay of 1-4 on the CPU board. The discrete signal outputs the relay of 5-7 on the signal board. The conversion-frequency board locates inside operation faceplate-cover. It directly installs bottom of the device’s cover. It main makes up of power transformer, main relay,the IGBT module and control circuit. The transformer supplies for the device. The IGBT module accepts CPU board control, which fulfill A.C-D.C-A.C switch. It realizes conversion-frequency control to the motor.
3.3 Additional gearbox Some actuator equipped with additional gear-box to meet customer’s special requirement of torque.The digital brand on the additional gearbox record concerned input torque and force and so on.
4 Technique parameter table.2 Technique parameter Output
Stroke Flange Power Speed without shaft (ISO5210) (kW) (r/min) sleeve(mm)
Current (A)
Max. recommended torque(Nm)
adjustable torque range (Nm)
M8610 M8510
30
20-50
7-35
190
F10
0.5
0.88
M8620 M8520
60
40-100
7-35
190
F10
0.85
1.75
M8630 M8530
120
80-200
7-35
190
F14
2.0
3.5
M8640 M8540
240
160-400
7-35
230
F16
3.0
7.0
M8650 M8550
360
240-600
7-35
230
F16
5.0
10.5
Actuator
6
4.1 Currency data Power voltage: AC 380V 3PH;-10%/+15%;50Hz/6OHz±5% Optional choose: AC 415V 3PH;-15%/+10%;50Hz/6OHz±5% AC 220V 1PH;-10%/+10%;50Hz±5% (According to user’s request) External power: 24V DC (18 V -33V), Max. 500mA output, It is redundancy power of electric unit part. Voltage output: 24V DC Max.15 mA, It has output short protect. Motor control: Three phases conversion-frequency control Working mode: S4—25% 1200 times/hour, according to IEC IEC34 The protection degree: IP67 Optional choose IP68.During transportation and stoage, it is IP IP43. Humidity: <95% average (to avoid atomization, please use heater). Ambient temperature: -25℃- +70℃ Installing position: at will. But you should avoid two oil discharge plugs to be in or approach the same level. Electric connection: see the seventh part The shortest setting pulse: 50ms full pulse Dead band of the controller : 0.5%;(0.2%-10%can be adjusted.) Analog signal input (optional choose): 4mA-20mAd.c. ( M86 □ □ ) Isolation with electricity, rising characteristic, input voltage is less than 10 V. Digital input(E1-E4): four routes light coupling isolation input, potential independent, free configuration Digital 0: -3V~+5V or open circuit. Digital 1: +12V~+35V Analog output(optional choose): 4mA ~ 20mAd.c.position signal, load capacity, Max.500Ω,isolation with electricity, rising characteristic, temperature effect ±0.5%/10K Digital output: four of standard (A1-A4)Optional choose three(A5-A7) Thereinto, the Max. output capacity of A3and A4 is 3A,220Va.c. The rest of Max.digital output voltage is less than 50V, the Max.current is less than 150 mA and the Min.current is more than 1mA . The default setting of output content see table 1. You can set them to the other alarm output in output configuration of the discrete signal of P6 menu according to your request.
5 Lubricate 5.1 Actuator The actuator need to use lubricate. There is unlimited on the location of the installation( see 6.2 part of the instruction manual). You needn’t to change lube during the whole life of the actuator. For supplying, two holes of discharged oil need to be sealed with oil plug. Once the actuators install to proper position, you must make the most top of discharged oil bolt to change discharged gas with random. So it can avoid the air inside the hull of the actuator dilate and press increase when the actuator running.
7
5.2 Lube See Fig.3 table.3 Lube Actuator
Oil
M8610/M8510
0.3L
M8620/M8520
0.3L
M8630/M8530
0.4L
M8640/M8540
0.8L
M8650/M8550
0.8L
The type of oil
The range of temperature
Heavy-load gear oil
-25℃~+70℃
5.3 Additional gear-box Some actuators need to connect a additional gear-box for upgrade output torque and limit running range. So they need to lubricate for upgrading life.
5.3.1 Worm wheel We advise to change a lube after running six years. 5.3.2 Linear switch unit We advise to change a lube after running 4-5years.
5.4 Assistant output module (A mode) For lever/linear switch, the actuator can install assistant output module A. It lubricates interior axletree by lube of module connection sleeve. It need to replenish lube every other two months. Use the same lube to valve’s stem.
6 Installing 6.1 The inspection of actuator �
Whether the actuator was proper connect with the value?
�
Whether using the most top of discharged oil bolt to change discharged gas with random.
�
Checking setting valve of cutting torque (P1.3, P1.4), torque setting shouldn’t be over stated range of the 11th part.
�
Checking speed setting (P1.5,P1.6)
6.2 Installing notes �
Installing position is unlimited. But you should avoid two oil diacharge plugs to be in or approach the
same level. All directions of the actuator can operate with hand, electric connection or local. Special note : When electric actuator (M8510 ~ M8530/M8610 ~ M8630) combine with the corner-type gearbox(with lever A8005L~ A8090L) ,there is interference when output lever run to upper position , see Fig.2, (fig 2a-b) is standard combination position when leaving factory. For fig 2c and 2d of table 4 " × " shows interference happened in assembly, it's not recommended to adopt. Except standard installation position, user should estimate if there is interference of lever turning position when other combination position is used. �
8
Rotation angle
Fig 2a
Fig 2b
Fig 2d
Fig 2c
Fig 2 Position diagram of electric actuator and corner-type reducer with lever
Table 4 Installation way Item
Model
Fig 2d
Fig 2c
Lever on the left
Lever on the right
1
M856 10+A8005L
2
M856 10+A8010L
×
3
M856 20+A8020L
×
4
M856 20+A8040L
×
5
M856 30+A8040L
×
6
M856 30+A8090L
×
Note: 1. Lever on the left or the right is depends on the situation of facing the lever and above the actuator. 2. Marking with “×”means not suitable to use combination collocation because of interference. � �
� � �
If the actuator exposures in heat-source, it need to use separate layer or heat-shield. When the outer power is interrupted, the actuator use the back-up lithium battery to record manual valve’s running. The lithium battery is installed the top of connection terminal box. When the top switch of battery should be cut during transport and stock, the battery circuit is disconnect. After installing and adjusting, the switch need to dial connected position. When exceed the factory, the actuator isn’t be pre-adjustmented (the range of operation isn’t defined). After connection of machine and electric, adjust running range again.(see P1.1 and P1.2 of 8.1.1) The handwheel and ventilation plug for replacement supplied by manufacturer are not installed before leaving factory. After installation the whole set, the supplied parts should be installed and displaced. When user purchase the electric actuator (M8300/ 8400) without additional unit or second stage reducer, manufacturer should supply accessories: one piece of positioning ring (see graphic representation in page 13), it's not installed when leaving factory. User must install it during connection. 9
�
The actuator’s eyebolt is only used for hoisting actuator.After the actuator and converter or valve are assembled, the whole weight increase. You need to adopt suitable binding rope in right position when rise.
7 Electric connection The down-lead assign of terminal connection see Fig.3. They direct connect to terminal row of the product’s connection-box though cable.
Fig.3
External connection terminal (the contact hasn’t been triggered).
7.1 Connection Allowed load of contact see the 4th part in this instruction. Screening all signal cables. There is only a contact between the wire of connected with the earth and the actuator. Recommended connection of system. see Fig.3.
21
L
3PH380V 50/60Hz
L
7 Full
P 22
16
8
L M8500/8600
+ 36 output 4~20mAd.c. 35
open 21 11 close 13
L M8600
+ 34 Input 4~20mAd.c. 33
9
15
Zero
L
3PH380V 50/60Hz
L P
10 22 12 14
M8500、M8600discrete signal
M8600analog signal
Fig.4 Recommended basic connection 10
1
4~20mAd.c. DCS modul ating
ZM 13 34 M8 21 1 4□ C-26 □/ 15 2 03 14 33 Intell 3 16 igent opera 17 tion 4
11
M8
36 35
syste m
2
22 6□ □A 16 ctu ato
3
D DCS DCSD CS modul ating syste m
4 5 14 15
DFQ- 12 2103K 13 Opera 7 tion 8
36 35 M 13 83 12
11
21
□□
7
/M 85
14
9
□□
22
9
1
10
3
Ac tua 8
(a) System wiring of actuator with analog signal control
10
(b) System wiring of actuator with switch signal control
Fig 5 Recommending system wiring
7.2 Wire diameter choice (contact connection) Power cable: 2.5~4mm2 hand wire or 4mm2 soft wire Signal cable: 0.5~1.5mm2 hand wire or 4mm2 soft wire
7.2.1 The screw thread dimension of cable sealing entry.
Terminal (Standard)
Standard(Metric)
Recommended the outer dimension of cable(mm)
2×M32×1.5
15-21
1×M25×1.5
12-16
PG Optional choose(PG PG) PG 1×PG PG21 PG 1×PG PG16 PG 1×PG PG13.5
During transportation, the screw thread hole of cable’s sealing entry was covered with plug screw. The grade of protect was ensured by the sealing of cable entry. Please use enter-cover that collocated random allocation and collocate fit cable of outer dimension. If necessary, you can smear sealant in cable’s entrance to ensure specified protection degree.
7.3 Safety Main power’s insurance locate in filter board. It’s specification is 3×15A(M8610-M8630),or 3×25A(M8640/8650),Φ6.3×32;(the same as M8500 series) Digital output and external 24V.DC adopt self-renew insure. They locate in I/O board. When failure happens, they are returned to factory for maintenance.
8 Parameter setting and faceplate operation The actuator goes along configuration adjustment (setting position, Setting parameter, collocate, LOCAL diagnose and so on) by control board. All setting can process in this device’s control board by “LOCAL LOCAL” (local operation). The device’s control board is installed in electric unit. It contains the parts as follows: Mode choose switch switch: mode choose switch reaches to: � Remote Remote: remote control 11
�
�
�
O/S O/S: It can’t operate(this serve is invalid). Local Local: It can operate and set (setting position, setting parameter, collocate, diagnose and so on) by this device. MODE/STOP Button Button: It involves increase button(+), decrease button(-) and mode button(MODE/STOP MODE/STOP),See Fig.4. After opening cover of operation board, there are three button-switches in CPU board which unction is the same as above three buttons. The mode selector-switch displace CPU board from the top-left jumper. Before installing cover, you need to put the jumper to the O/S O/S. LCD display display: see Fig.5 the digital of up-row displays the signal of value opening. When setting work, it displays the codes of adjustment parameter or parameter values. When lighten the symbol of “%” means that the digital is percent. Otherwise it is the other digital. When the character of below-row is running, it shows current work. During setting, it shows the code of parameter name or failure alarm commonly. LED LED: The green LED means “ the main power can use”. The red LED means “ failure or alarm that can’t continue operating”.
Fig.4 Operation faceplate
Fig.5 Display
12
8.1 By the operation and adjustment of control board. Operation/adjustment menu is divided into 7 main menu: � P1 SETUP � P2 PARAMETR SETUP �
P3 DIAGNOSE
�
P4 MACHINE DATA
�
P5 CALIBRAT CALIBRATION
�
P6 DIGITAL OUTPUT CONFIGURATION
� P7 INSTANCY OPERATION Every main menu can be divided into one or several sub menu. Before operation or adjustment of control board, put mode selection switch to LOCAL position, see figure 3. mode/stop key have long press and dot press operation ways, long press is used to enter menu, dot press is used to confirm or quit menu. “+”“-”key are used to up and down search menu or setup increasing or reducing of parameter, when local operation or setup valve position to zero and full point, it can drive output shaft turn. Before drive actuator, setup operation range of output shaft. In LOCAL mode long press MODE key→P1,long press MODE key →P1.1,long press MODE key to enter zero setup, press “+” or “-”key,output shaft turn to required mechanical zero position, dot press MODE key, select to save current setup zero position. Dot press “+” key to enter into P1.2 and set full bit, use same way, operate output shaft of actuator to mechanical full bit, save and then exit, finish operation range setup of output shaft. Attention: There must be min. interval between zero and full bit of actuator, when output shaft doesn’t reach min. adjustable range, 4 lines will be shown in display“- - - -”,when actuator exceed min. adjustable range, line will change to “□□□□”.
8.1.1 Menu function see table 6. Table 6 Main menu P1 COMMON SETUP
Sub menu
Menu
Menu function
Display or explaination
P1.1 ADJUST_C
Setup valve position to zero
P1.2 ADJUST_O
Setup valve position to full dot
stroke range meet min. requirement and display “□□□□”
P1.3 TORQUE_C
Closing torque
40~100%(10% step)
P1.4 TORQUE_O
Opening torque
40~100%(10% step)
P1.5 SPEED_C
Closing speed
20~100%(5% step)
P1.6 SPEED_O
Opening speed
20~100%(5% step)
P2.1 CUTOFF_C
Closing is chosen by stroke or torque switch off
T TRAVEL_D TRAVEL_D(stroke)/ TORQUE_D TORQUE_D(torque)
Closing stroke switch off position
0~45%(1% step)
Opening is chosen by stroke or torque switch off
TRAVEL_D TRAVEL_D(stroke)/ TORQUE_D TORQUE_D(torque)
Opening stroke switch off position
55~100%(1% step)
P2.2 LIMIT_C P2.3 CUTOFF_O P2 PARAMETR P2.4 LIMIT_O SETUP P2.5 SWITCH P2.6 ALM_DEAL
Digital input inching/self- holding HOLD(self-holding) INCH(inching),HOLD selection Signal break off disposal way 13
On HOLD HOLD(holding),On OFF (full opening),OFF OFF(full closing)
Main menu
Sub menu
Menu function
Display or explaination
P2.7 PLACE_C
Low terminal midway alarm
0~45% less or equal setting value alarm
P2.8 PLACE_O
High terminal midway alarm
55~100% more than or equal setting value alarm
Dead zone
0.2~10%
P2.9 DBAND
Note 1:P2.2、P2.4 can operate only “position correlative switch” is chosen. Note2 : If choose switch off according to torque, system should be in self-holding working mode, it’s wrong to choose inching working mode. P3.1 ERR_ACTU
Trouble sheet
P3.2 ALM_ACTU
Alarm information sheet
Observe current sampling value of modulating signal
P3.5 TEMP_MOT
Motor winding temperature
Observe current motor winding temperature
P3.6 TEMP_ELC
Electronic unit temperature
Observe current electronic unit circumstance temperature
Battery voltage
Observe current battery voltage
P4.1 TIME_C
Closing stroke time
P4.2 TIME_O
Opening stroke time
P4.3 SW_VER
Software revision no.
P4.4 HW_VER
Hardware revision no.
P4.5 ADDRESS
Communication address
Value range 0~255
Enter calibration password
Password is 51
Adjust input zero
Set modulating signal to 4mA,inching “+”or“-”key, save and exit after confirmation.
Adjust input full
Set modulating signal to 20mA,inching “+”or“-”key, save and exit after confirmation.
Feedback output zero
Inching “+”or“-”key and adjust feedback output signal to 4mA and then save, exit.
Feedback output full
Inching “+”or“-”key and adjust feedback output signal to 20mA and then save, exit.
P5.1 PASSWORD P5.2 INPUT_Z
P5.3 INPUT_F
P5.4 OUTPUT_Z
P5.5 OUTPUT_F P6 DIGITAL OUTPUT CONFIGUR ATION
use +,- key to check
Modulating signal
P3.7 BATTERY
P5 CALIBRAT
If more than one alarm information, Change 20 codes when handwheel turn one circle
P3.4 INPUT
P4 MACHINE PARAMETE R
information If more than one trouble information, use +,- key to check
Hall sensor diagnosis
P3 SELF P3.3 HALLCODE DIAGNOSE
P3 SELF DIAGNOSE
diagnosis
P6.1 PASSWORD Enter digital configuration password P6.2 OUTPUT_1
A1 digital output configuration
P6.3 OUTPUT_2
A2 digital output configuration
P6.4 OUTPUT_3
A3 digital output configuration
P6.5 OUTPUT_4
A4 digital output configuration 14
Password is 61 Configuration range see table 7 I/O output configuration
Main menu
P7 EMERGEN CY OPERATIO N
Sub menu
Menu function
Display or explaination
P6.6 OUTPUT_5
A5 digital output configuration
P6.7 OUTPUT_6
A6 digital output configuration
P6.8 OUTPUT_7
A7 digital output configuration In emergency pay no attention to alarm information and drive output shaft moving, but it’s possible to damage some function
P7.1 INSTANCY
Emergency operation
P7.2 POS_INST
You can estimate opening and set Emergency setup current valve valve position value directly according to when valve position is lost current output draft position.
Digital output can be changed by P6 digital output configuration, the optional range of digital configuration see table 7.
Table7 I/O output configuration range I/O output
A1
First group
A3
A5
A7
A2
Second group
A4
A6
Optional range
Information explanation
Information display
Default value
Move in normal situation Switch off in trouble situation
Display FAILURE “FAILURE FAILURE” if trouble happens
Operation preparation trouble alarm
Over torque
TORQUE_E
Over torque in opening
TORQUE_O
Valve position is more than setup value of high terminal
PLACE1_O
Valve position over limit or lost
POS_LOSE
Open to terminal
ADJUST_O
Local/remote
REMOTE
Adjustment signal switch off
NO_SIGN
Integrative alarm
ALARM
Battery low or empty
BATTERY
Temperature over limit
TEMP
Optional Over torque in closing range Valve position is less than setup value of low terminal Close to terminal
15
TORQUE_C PLACE2_C ADJUST_C
Open to terminal
Over torque in opening
Local/remote
Integrative alarm Close to terminal
Over torque in closing
8.2 Save setup First use +/- button of display to set new parameter, then short press stop/mode button, if parameter is SAVE changed, display will show static “SAVE SAVE”. If you want to cancel, press + or – button to operate, then press STOP/MODE button to return. SAVE If you want to save new value, press STOP/MODE button, flashing “SAVE SAVE” shows saving process.
9 Alarm and trouble Intelligent frequency conversion actuator have strong function, after analysis function start(P3 menu, see section 8 of manual), see information via LCD LCD, table 8 and 9 describe alarm and trouble information.
9.1 Alarm Definition: Alarm system start automatically when actuator reaches to critical situation, actuator continues working. If always keep such status, actuator will stop running.
9.2 Alarm information Because chosen operation mode is different, interval flashing display of alarm information just as 0/S/ALARM or REMOTE/ALARM LOCAL/ALARM LOCAL/ALARM,0/S/ALARM REMOTE/ALARM, detailed information in main menu of alarm sheet P3.2, when several trouble happens at same time, only show trouble and no alarm display. Table8 Display character IN_SIGN BAT-CHANG BAT-EMPT
LCD display alarm information
Alarm description Adjustment signal switch off. But in remote switch control condition, no analysis to adjustment signal break off. The power of battery is not enough, exchanging should be done immediately. If battery empty, data exists if power off, but hand-wheel drive can cause valve displacement, when power on, valve position should be set again.
TORQUE-0
Opening torque alarm, load torque more than optional opening alarm value.
TORQUE-C
Closing torque alarm, load torque more than optional closing alarm value.
TEMP-MOT
TEMP-ELC IN_SIGN
The temperature of motor over limit, alarm if above 110℃,release from alarm if reduce to 100℃. The temperature of electronic part over limit, alarm if above 80℃,release from alarm if reduce to 75℃. Adjustment signal switch off
TORCNT_C
The time of over torque in closing is more than 10000
TORCNT_O
The time of over torque in opening is more than 10000
STARTCNT
Startup time is more than 5×107
ENDCNT_C
The time of closing terminal is more than 107
ENDCNT_O
The time of opening terminal is more than 107
RUNTIME
Total running time is more than 10 years 16
9.3 Trouble Hardware/software have problem or incorrect handling of operator, actuator will show trouble information automatically. Trouble shooting should follow the process. If trouble endanger personnel or actuator, please switch off power. M8500/8600 series abnormity
Manual operate the actuator Normal
Can’t run or running is difficulty
Electric failure
Machine failure
Divorce from valve,manual operate actuator Normal
Don’t run
Reducer fault
Checking failure menu P3.1 and alarm menu P3.2
Valve was block Failure diagnose process
9.4 Trouble information Interval flashing display of alarm information in LCD just as LOCAL/ALARM , 0/S/ALARM or REMOTE/ALARM REMOTE/ALARM, detailed trouble information sheet see menu P3.1.The meaning of trouble information see table 9. Table 9 LCD display trouble information Display character ELECTR TEMP-MOT TEMP-ELC RELAY
Trouble description Trouble of electronic unit The temperature of motor exceed limitation. Alarm above 120℃, release from alarm if down to 110℃. The temperature of electronic unit exceed limitation. Alarm above 85℃, release from alarm if down to 80℃. Main relay doesn’t connect
END_POS
Actuator operation exceed terminal position
POS_LOSE
Valve position lost
17
10 Actuator outline and installation dimension See the following drawing and table about actuator outline and installation dimension.
M8610 /M8510
M8620 /M8520
M8630 /M8530
M8640 /M8540
M8650 /M8550
ISO ISO5210
F10
F10
F14
F16
F16
A1
207
207
226
250
250
A3
133
133
152
169
169
B2
50
50
63
80
80
C3
99
99
99
82.5
82.5
D1
R99
R99
R99
R95
R95
E
253
253
266
294
294
F
574
598
665
768.5
768.5
H1
94.5
94.5
94.5
140
140
H2
104.5
104.5
104.5
148
148
H3
202
202
202
250
250
H5
214
214
214
270
270
M1
Φ105
Φ120
Φ140
Φ225
Φ225
M2
136
160
192
316
355
M3
285
313
373
375
470
18
Actuator output flange dimension
stop ring Type
Flange code
D
D1
M86(5)10
F10
125
102
M86(5)20
F10
125
M86(5)30
F14
M86(5)40
D2
D5
H1
H2
53
60
15
7
102
53
60
15
7
175
140
74
88
24
8
F16
210
165
98
120
30
12
M86(5)50
F16
210
165
98
120
30
12
Type
Flange code
H3
H4
H5
L1
B1
M86(5)10
F10
47.6
3.5
3
45.3
12±0.0215
4-M10
M86(5)20
F10
47.6
3.5
3
45.3
12±0.0215
4-M10
M86(5)30
F14
53
4.1
4
64.4
18±0.0215
4-M16
M86(5)40
F16
80
5
5
85.4
22±0.026
4-M20
M86(5)50
F16
80
5
5
85.4
22±0.026
4-M20
19
D3
D4
B2
n-d
11 Lever mode additional reducer 11.1 Technical data Adjustment Speed Recommend Output switch off Max. switch range of adjusting ed adjusting torque range of off torque Nm actuator switch rage reducer (Nm) torque Nm off torque(%) (s/90°)
Reducer
250
300
200-450
40%-80%
30-150
A8005
500
800
450-900
40%-80%
30-150
A8010
800
1000
600-1200
40%-100%
32-161
1200
1600
1150-1800
40%-70%
32-161
1600
2000
1200-2500
40%-100%
32-161
2500
3600
1600-3600
40%-70%
32-160
4000
4500
2400-6000
40%-100%
32-160
6000
8000
4000-8000
40%-100%
32-160
10000
12000
6000-10000
40%-100%
43-214
12000
15000
10000-15000
40%-100%
43-214
8000
12000
8000-12000
40%-100%
43-214
Actuator
M8610 /M8510
A8020 M8620 /M8520 A8040 M8630 /M8530 A8090 M8640 /M8540 A8160
M8650 /M8550 M8640 /M8540
A8200
M8650 /M8550
12000
18000
12000-18000
40%-100%
43-214
16000
24000
16000-24000
70%-100%
85-418
A8400+G6804
M8640 /M8540
24000
35000
24000-36000
70%-100%
85-418
A8400+G6804
M8650 /M8550
Note:1)If switch off torque of actuator is within 40%-100%,the setup step size is 10%. 2)If stroke time is within 20%-100%, the setup step size is 5%.
11.2 Universal parameter A8005
A8010
A8020
A8040
A8090
A8160
A8200
A8400+G6804
Actuator flange ISO5210
F10
F10
F10
F10/F14
F14/F16
F16
F16
F16
Valve flange ISO5211
F10
F10
F14
F16
F25
F30
F40
F40
Max. valve stem size mm
30
40
75
80
105
105
115
150
Weight kg
7(14) 14(26)30(49)
46(77)
20
72(141) 191(209) 321(378)
339(567)
11.3 Outline and structure dimension of reducer Outline and structure dimension of lever electrical actuator (directly mounted) (right turn hand-wheel, position index turn right)
A8005
A8010
A8020
A8040(+G65)
A8090 (+G65)
A8160
A8200
A8400 +G68
a
52
68.5
93.5
114
150
160
250
250
b1
100
108
142
151.5
175
198
266
309.5
b2
52
62
81
83
94
113
160
166.5
b4
96
104
133.5
138
166
193
260
298.5
Φ1(f7)
70
70
130
200
230
300
300
Φ2
102
102
140
165
254
298
406
406
Φ3
115
148
204
244
310
350
532
535
Φ4
80
95
136
159
196
220
265
288
k
3
3
4
4
4
5
5
d/dmax
20/30
20/40
35/75
35/80
54/105
54/105
54/115
60/150
h
81
81
104
130
133
158
235
260
h1
37
35
45.5
68
48
73
95
100
b3
m1
(M8610/M8510)=106
(M8620/M8520)=120
(M8630/M8530)=137
m2
(M8610/M8510)=285
(M8610/M8510)=313
(M8610/M8510)=350
s/s1
385
431
487(698)
527(512)
(736)
(859)
(882)
1100
t
147
176.5
295.5
246
310
592
530
577
x
(M8610/M8510/M8620/M8520)=450
(M8630/M8530)=491
y
(M8610/M8510/M8620/M8520)=253
(M8630/M8530)=266
21
Outline and structure dimension of lever electrical actuator(with lever)(right turn hand-wheel, position index turn right), see following drawing.
Rotation angle
Note: ① Show in drawing, it’s possible that connecting rod or lever collide with motor, pay attention to avoid. Dimension
A8005
A8010
A8020
A8040 (+G65)
A8090 (+G65)
A8160
A8200/A8 250
A8400 (+G68)
q
1×70
1×80
1×94
1×102
2×80
2×80
3×70
3×70
a1
36
34
48
50
56
62
70
70
b
140
135
223
270
338
448
580
580
b1
20
52.5
36
40
36
36
25
25
c
15
15
25
23
24
30
30
30
f
180
240
295
350
410
520
630
630
d(h8)
Φ16.2
Φ19.8
Φ23.4
Φ26.6
Φ34
Φ34
Φ33.8
Φ33.8
D
Φ18
Φ22
Φ26
Φ30
Φ38
Φ38
Φ38
Φ38
h
107
134
170
200
235
250
310
350
i max
66
86
100
119
143
143
150
150
k
198
218
265
304
415
415
470
470
k1
98
124
133
176
191
206
248
243
k2
177.5
207.5
232
284.5
320
339
405
437
l
132
132
165
185
272
272
320
320
m
8
10
0
17
0
0
0
0
n
20.5
24
28
36
40
40
42
42
p(p1)
207
263.5
332
668
666(751)
915
r
160
200
200
250
250
250
500
500
s(s1)
420.5
477
546
583(764)
676(832)
882
880
1129
u-Φs
4-Φ14
4-Φ14
4-Φ18
4-Φ22
6-Φ22
6-Φ22
8-Φ22
8-Φ22
369.5(549.5) 462(618)
x
(M8610/M8510/M8620/M8520)=450
(M8630/M8530)=491
y
(M8610/M8510/M8620/M8520)=253
(M8630/M8530)=266
a
52
68.5
93.5
114
22
150
160
250
250
12 Linear mode additional reducer 12.l Technical data Max. working thrust(Kn)
Max. speed (mm/s)
Stroke (mm)
Valve flange
Transformer
Actuator
8
2.9
50,100
F10
L8210
M8610/M8510
16
2.9
50,100
F10
L8220
M8610/M8510
25
3.5
63,125
F10
L8230
M8620/M8520
40
4.1
60,100,160
F14
L8240
M8630/M8530
Note:1) Working thrust is 50% of max. switch off thrust 2) Setup stepping is 5%
12.2 Outline and installation dimension of linear mode additional reducer 12.2.1 Dimension with flange
L8210
L8220
L8230
L8240
Valve flange
F10
F10
F10
F14
Actuator
M8610/M8510
M8610/M8510
M8620/M8520
M8630/M8530
Actuator flange ISO5210
F10
F10
F10
F14
Stroke H
50
100
50
100
63
125
60
100
160
d1
125
125
125
175
d2
70f8
70f8
70h7
100f8
d3
102
102
102
140
d4
Φ11
Φ11
Φ11
Φ18
d8
M12×1.25
M16×1.5
M20×1.5
M36×3
g1
191
241
191
241
234
296
293
373
h
3
3
3
4
h3
15
15
15
18
L2
20
25
30
55
L4
44
49
54
74
d9
20
20
32
50
23
13 Multi-turn additional reducer 13.1 Technical data Output Actuator Reducer
Recommended adjusting torque (Nm)
Switch off Speed torque(Nm) (r/min)
Flange
Power Current (kW) (A)
Weight (Kg)
M8650 M8550
G7010
900
600-1500
2.6-13
5
5.0
10.5
110
M8650 M8550
G7020
1800
1080-2500
1.5-7.5
7
5.0
10.5
135
M8650 M8550
G7030
2400
1500-3500
1-6
8
5.0
10.5
160
ti 13.2 Outline and installation dimension of mul multi ti-- turn mode additional reducer
Actuator mode
M86(5)50+G7010
M86(5)50+G7020
D
275
D1
235
285
340
D2
180
220
280
D3
82
98
118
D4
62
74
80
H
560
630
645
H1
25
30
35
H2
14
16
20
H3
2
3
3
H4
7
8
8
A
620
620
620
B
550
550
550
N-d
4-Φ22
4-Φ26
8-Φ22
330
24
M86(5)50+G7030 380
25