ARTICLE 2



ASME BPVC.V-2017



T-231.2 Processing. Standard Guide for Controlling the Quality of Industrial Radiographic Film Processing, SE-999, or Sections 23 through 26 of Standard Guide for Radiographic Examination, SE-94, may be used as a guide for processing film, except that Section 8.1 of SE-999 is not required.



T-232



Table T-233.2 Wire IQI Designation, Wire Diameter, and Wire Identity Set A Wire Diameter, in.



(mm)



Wire Identity



Wire Diameter, in.



(mm)



Wire Identity



0.0032 0.004 0.005 0.0063 0.008 0.010



(0.08) (0.10) (0.13) (0.16) (0.20) (0.25)



1 2 3 4 5 6



0.010 0.013 0.016 0.020 0.025 0.032



(0.25) (0.33) (0.41) (0.51) (0.64) (0.81)



6 7 8 9 10 11



Wire Diameter, in.



(mm)



Wire Identity



0.100 0.126 0.160 0.200 0.250 0.320



(2.54) (3.20) (4.06) (5.08) (6.35) (8.13)



16 17 18 19 20 21



INTENSIFYING SCREENS



Intensifying screens may be used when performing radiographic examination in accordance with this Article.



T-233



IMAGE QUALITY INDICATOR (IQI) DESIGN



T-233.1 Standard IQI Design. IQIs shall be either the hole type or the wire type. Hole-type IQIs shall be manufactured and identified in accordance with the requirements or alternates allowed in SE-1025. Wire-type IQIs shall be manufactured and identified in accordance with the requirements or alternates allowed in SE-747, except that the largest wire number or the identity number may be omitted. ASME standard IQIs shall consist of those in Table T-233.1 for hole type and those in Table T-233.2 for wire type.



Set B



Set C



Set D



Wire Diameter, in.



(mm)



Wire Identity



0.032 0.040 0.050 0.063 0.080 0.100



(0.81) (1.02) (1.27) (1.60) (2.03) (2.54)



11 12 13 14 15 16



T-233.2 Alternative IQI Design. IQIs designed and manufactured in accordance with other national or international standards may be used provided the requirements of either (a) or (b) below, and the material requirements of T-276.1 are met.



Table T-233.1 Hole-Type IQI Designation, Thickness, and Hole Diameters



IQI Designation 5 7 10 12 15 17 20 25 30 35 40 45 50 60 70 80 100 120 140 160 200 240 280



IQI Thickness, in. (mm) 0.005 0.0075 0.010 0.0125 0.015 0.0175 0.020 0.025 0.030 0.035 0.040 0.045 0.050 0.060 0.070 0.080 0.100 0.120 0.140 0.160 0.200 0.240 0.280



(0.13) (0.19) (0.25) (0.32) (0.38) (0.44) (0.51) (0.64) (0.76) (0.89) (1.02) (1.14) (1.27) (1.52) (1.78) (2.03) (2.54) (3.05) (3.56) (4.06) (5.08) (6.10) (7.11)



1T Hole Diameter, in. (mm) 0.010 0.010 0.010 0.0125 0.015 0.0175 0.020 0.025 0.030 0.035 0.040 0.045 0.050 0.060 0.070 0.080 0.100 0.120 0.140 0.160 0.200 0.240 0.280



30



(0.25) (0.25) (0.25) (0.32) (0.38) (0.44) (0.51) (0.64) (0.76) (0.89) (1.02) (1.14) (1.27) (1.52) (1.78) (2.03) (2.54) (3.05) (3.56) (4.06) (5.08) (6.10) (7.11)



2T Hole Diameter, in. (mm) 0.020 0.020 0.020 0.025 0.030 0.035 0.040 0.050 0.060 0.070 0.080 0.090 0.100 0.120 0.140 0.160 0.200 0.240 0.280 0.320 0.400 0.480 0.560



(0.51) (0.51) (0.51) (0.64) (0.76) (0.89) (1.02) (1.27) (1.52) (1.78) (2.03) (2.29) (2.54) (3.05) (3.56) (4.06) (5.08) (6.10) (7.11) (8.13) (10.16) (12.19) (14.22)



4T Hole Diameter, in. (mm) 0.040 (1.02) 0.040 (1.02) 0.040 (1.02) 0.050 (1.27) 0.060 (1.52) 0.070 (1.78) 0.080 (2.03) 0.100 (2.54) 0.120 (3.05) 0.140 (3.56) 0.160 (4.06) 0.180 (4.57) 0.200 (5.08) 0.240 (6.10) 0.280 (7.11) 0.320 (8.13) 0.400 (10.16) 0.480 (12.19) 0.560 (14.22) 0.640 (16.26) … … …