12 0 52 KB
BlueScope Steel Australia: LYSAGHT BONDEK®
Page 1 of 2
LYSAGHT BONDEK® Product Description and Features LYSAGHT BONDEK® profiled steel decking is a highly efficient, versatile and robust formwork, reinforcement and ceiling system for concrete slabs. It is a profile steel sheeting widely accepted by the building and construction industry to offer efficiency and speed of construction. • Excellent spanning capacities for greater strength and less deflection • Acts as permanent formwork with minimal propping and no stripping of LYSAGHT BONDEK® formwork is required • Fast and easy to install (590mm wide) with less handling required • Works as composite slab saving on concrete and reinforcement costs • Ribs at 200mm centres creating a safe working platform with slip resistant embossments • Advanced design for fire resistance • New BONDEK® software gives added flexibility and ease of design • Increased unsupported spans of BONDEK® sheeting • Backed by a BlueScope Steel warranty • Nationwide technical support
Warnings • Design & detailing should be carried out by a qualified structural engineer
Product Details Specification
Tolerance Length: +0mm, -10mm
Specification LYSAGHT BONDEK® profiled steel sheeting is roll-formed from hot dipped, zinc-coated, hi-tensile, steel strip, in base metal thicknesses (BMT) of 0.60, 0.75, 0.90 and 1.0mm. The steel strip conforms to AS1397 grade G550, Z350. 0.9mm thickness is available for projects by special order. Pre-painted BRITEWITE® soffit is also available on enquiry.
Physical Properties Thickness Mass Yield Coverage (mm) Strength m2/t kg/m2 kg/m MPa 0.60 0.75 0.90 1.00
8.52 10.50 12.48 13.79
5.03 6.20 7.36 8.14
550 550 550 550
117.37 95.24 80.16 72.52
http://www.bluescopesteel.com.au/index.cfm/objectID.D85CCD4B-0558-11D4-89F00... 11/6/2009
BlueScope Steel Australia: LYSAGHT BONDEK®
Page 2 of 2
Schematic
Availability
Availability LYSAGHT BONDEK® is available in all states.
Design
Spanning Tables Span tables for LYSAGHT BONDEK® can be found in our Users Guide: Download LYSAGHT BONDEK® Users Guide (703 KB) Professional members of our Website can download the full Design Manual from: LYSAGHT BONDEK® 2008 Design and Construction Guide and Software
FAQs •
What type of building applications can LYSAGHT BONDEK® be used in?
•
Can LYSAGHT BONDEK® be fire-rated?
•
How far can LYSAGHT BONDEK® span as formwork?
http://www.bluescopesteel.com.au/index.cfm/objectID.D85CCD4B-0558-11D4-89F00... 11/6/2009