26 0 8 MB
Japan Sewerage Works Association Standard
JSWAS A-2 - 1999 Jacking Reinforced Concrete Pipes for Sewerage (Nominal Diameter 800 ~ 3000)
1. SCOPE
This Standard specifies the requirements for reinforced concrete pipes for the jacking method, hereinafter referred to as “the pipes”. Note: Figures in { } brackets are reference conventional units.
2. CLASSIFICATION
The pipes shall be classified into the Standard Pipe, and S & T Type Intermediate Jacking Pipes (hereinafter “Intermediate Pipes”), and further subclassified into “50” or “70” for concrete compressive strength, Class “1” or “2” for external strength, and JA, JB, or JC for joint specification. These are summarized as shown in Table 1.
Table 1: Pipe Designs Type
Shape
Standard Pipe
S
Intermediate
T
Pipe
External
Compressive
Joint
Strength
Strength
Specification
Class 1
50
Designation of Type
Applicable Pipe Size (nominal)
X 51
70
X 71 JA
Class 2
50
-
-
Class 1
50
XT51
Class 2
50
XT52
JB JC
X 52 XS
Notes: 1.
A set of Intermediate Pipes shall consist of S-Type and T-Type
2.
“X” in the above Designation of Type shall refer to JA, JB, or JC joint specification.
3.
“Joint” shall refer to the connected situation of the spigot and socket of the pipes.
4.
The requirements for Joint Specification shall be as shown in Table 3.
1
800~3000
1000~3000
3. QUALITY
The quality requirements for the pipes shall include appearance, external strength, concrete compressive strength of pipe, and joint specification.
3.1
Appearance The pipes shall be free of detrimental flaws, and the internal surface shall be smooth to the practical extent.
3.2
External Strength The external strength of the pipes shall be such that the pipes can withstand the applied loads as given in Table 2, when subjected to external strength tests as required in Section 7.1.
Table 2: External Strength of Pipes (Unit : kN/m {kgf/m}) Cracking Load
Nom. Dia
Class 1
Breaking Load
Class 2
Class 1
Class 2
800
35.4
{3600}
70.7
{7200}
57.9
{5900}
106
{10800}
900
38.3
{3900}
76.5
{7800}
64.8
{6600}
115
{11700)
1000
41.2
{4200}
82.4
{8400}
71.6
{7300}
124
{12600}
1100
42.7
{4350}
85.4
{8700}
78.5
{8000}
128
{13000}
1200
44.2
{4500}
88.3
{9000}
86.3
{8800}
133
{13500}
1350
47.1
{4800}
94.2
{9600}
98.1
{10000}
142
{14400}
1500
50.1
{5100}
101
{10200}
110
{11200}
151
{15300}
1650
53.0
{5400}
106
{10800}
122
{12400}
159
{16200}
1800
55.9
{5700}
112
{11400}
134
{13600}
168
{17100}
2000
58.9
{6000}
118
{12000}
142
{14400}
177
{18000}
2200
61.8
{6300}
124
{12600}
149
{15100}
186
{18900}
2400
64.8
{6600}
130
{13200}
155
{15800}
195
{19800}
2600
67.7
{6900}
136
{13800}
163
{16600}
203
{20700}
2800
70.7
{7200}
142
{14400}
170
{17300}
212
{21600}
3000
73.6
{7500}
148
{15000}
177
{18000}
221
{22500}
Notes: 1.
Cracking Load shall be the value which is indicated on the testing machine when a crack of 0.05mm appears, divided by the effective length of the pipe (L).Breaking Load shall be the maximum load indicated on the testing machine divided by the effective length of the pipe (L).
2.
For Intermediate Pipes, only Type T Intermediate Pipe shall be tested for Cracking Load.
2
3.3
Concrete Compressive Strength of Pipe Concrete compressive strength of pipe shall be equal to or greater than: 50N/mm2 {500kgf/cm2} for Class 1-50 and Class 2-50, or 70N/mm2 {700kgf/cm2} for Class 1-70.
3.4
Joint Specification Joint Specification shall be such that the joint can withstand the applied water pressures as given in Table 3, when subjected to water-tightness tests as required in Section 7.3.
Table 3: Joint Specification Category
Water Resistance
Extraction Length
(MPa)
(mm)
JA
0.1
30
JB
0.2
40
JC
0.2
60
Notes: “Extraction Length” shall refer to the gap between two pipes.
4. SHAPE, DIMENSIONS, AND DIMENSIONAL TOLERENCES
The shape, dimensions, and dimensional tolerances for Standard pipes, Intermediate Pipes, and Joint Groove, etc. shall be as given in Figures 1~5.
4.1
Joint Structure Joint structure shall be of such form that is confirmed under Appendix 1 (Joint Model Test Regulation). The detailed shape, dimensions, and dimensional tolerances of the joint shall be in accordance with the approved design of the pipes.
Additional fabrication that will not affect the shape or strength of the pipes shall be allowed.
3
4.2
Standard Pipe Shape, dimensions and dimensional tolerances of Standard Pipe shall be as shown in Figure 1.
Figure 1: Shape, Dimensions, and Dimensional Tolerances of Standard Pipe (Unit: mm) Grout hole
Grout hole
Collar
Socket
Spigot Notes: N o m in a l D ia D ia m e t e r
In te rn a l D ia m e t e r D
T h ic k n e s T
4
80
900
6
90
1000
1000
6
100
1100
1100
6
105
1200
1200
6
115
1350
1350
8
125
1500
1500
8
140
800
800
900
1650
1650
8
150
1800
1800
10
160
2000
2000
10
175
2200
2200
10
190
2400
2400
12
205
2600
2600
12
220
2800
2800
12
235
3000
3000
12
E f f e c t iv e L e n g th L
250
+ + + + + + + + + + + + + + + -
4 2 6 3 6 3 6 3 6 3 8 4 8 4 8 4 1 5 1 5 1 5 1 6 1 6 1 6 1 6
J o in t M in . T h ic k n e s s t 65 75 85 90 100 105 120
2430 0 0 0 2 2 2 2
+ 10 - 5
130 140 155 170 180 195 210 225
1. The effective length of standard pipe (L) may also be 1200 +10 / -5. 2. The steel collar may be omitted for standard pipe. The effective lengths of the pipes may be 2430 +10 / -20, or 1200 +10 / -20.
3. The difference of maximum and minimum measurements of effective length shall be within 3mm. 4. For pipes 1000mm and larger, pre-embedded locking sockets (for pipe-pipe connection) may be installed. 5. The positions and quantity of grout holes may be altered as necessary. 6. “Joint Minimum Thickness (t)” shall be minimum standard thickness of the pipe at the interface of the joint.
4
4.3
Intermediate Pipes Intermediate Pipes shall consist of one S-Type and one T-Type Intermediate Pipe, as shown in Figure 2. The shape, dimensions, and dimensional tolerances shall be as shown in Figures 3~4.
Figure 2: Arrangement of S-Type and T-Type Intermediate Pipes Type-S
Type-T
Cushion Ring
Figure 3: Shape, Dimensions, and Dimensional Tolerances of S-Type Intermediate Pipe Section View Rib
Motar or Concrete Fill
Motar or Concrete Fill
5
N o m in a l D ia m e te r
In te rn a l D ia . D
1000
1000
1182
1100
1100
1292
1200
1200
1406
1350
1350
1576
1500
1500
1756
1650
1650
1926
1800
1800
2096
2000
2000
2326
2200
2200
2556
2400
2400
2778
2600
2600
3008
2800
2800
3238
3000
3000
3468
Note:
D
c
L
tc
c
1100
+ 5 - 3
1150
+ 5 - 3
1200
+ 5 - 3
9
12
16
Additional fabrication to accommodate fitting of gasket to the spigot portion may be allowed as necessary.
6
Figure 4: Shape, Dimensions, and Dimensional Tolerances of T-Type Intermediate Pipe B-B Section View
Socket
Grout Holes (4 locations on circumference)
(Unit: mm) N o m in a l D ia .
In te rn a l D ia . D
D
1000
1000 6
1164
1100
1100 6
1274
1200
1200 6
1388
1350
1350 8
1551
1500
1500 8
1731
1650
1650 8
1901
1800
1800 10
2071
2000
2000 10
2301
2200
2200 10
2531
2400
2400 12
2749
2600
2600 12
2979
2800
2800 12
3209
3000
3000 12
3439
E ffe c tiv e L e n g th 1
t
2
T
1150
+ 5 - 3
1200
+ 5 - 3
1250
+ 5 - 3
6
9
7
L
4.4
Grouting Socket Socket used as grouting sockets for the pipes shall be as specified in JIS B 2302 (Screwed type steel pipe fittings); nominal size “2”. For pipes under nominal diameter 900mm, the same socket shall be shortened to half-length. The plug used for the socket shall be as specified in JIS B 2301 (Screwed type malleable cast iron pipe fittings); nominal size “2”.
Where socket and plug for the grout socket as specified above are not available, those having the same or higher-grade quality shall be used.
4.5
Joint Groove The shape of Joint Groove shall be as given in Figure 5.
Figure 5: Shape of Joint Groove
Cushion Ring
Joint Groove
4.6
Lubricant Inlet Steel tube used for lubricant inlet shall be as specified in JIS G 3452 (Carbon steel pipes for ordinary piping); nominal size 10(A), the socket shall be as specified in JIS B 2302 (Screwed type steel pipe fittings); nominal size “3/8”, and the plug shall be as specified in JIS B 2301 (Screwed type malleable cast iron pipe fittings); nominal size “3/8”.
Where steel tube, socket, and plug for the lubricant inlet as specified above are not available, those having the same or higher-grade quality shall be used.
8
5. MATERIALS 5.1
Cement Cement shall conform to one of the following, or have the same or higher-grade quality:
5.2
(1)
JIS R 5210
Portland Cement
(2)
JIS R 5211
Portland Blast-Furnace Slag Cement
(3)
JIS R 5212
Portland Pozzolan Cement
(4)
JIS R 5213
Portland Fly-Ash Cement
Aggregates Aggregates shall conform to Appendix 1 (Aggregates for Ready-Mixed Concrete) of JIS A 5308 (Ready-Mixed Concrete).
In the case of employing aggregates evaluated as “Category B” under the requirements in Appendix 1 of JIS A 5308, corrective measures shall be taken in accordance with requirements given in Appendix 6 of JIS A 5308 (Methods of Corrective Measures against Alkali-Aggregate Reactivity in Selecting Cement).
5.3
Water Water shall conform to Appendix 9 (Water for use with Ready-Mixed Concrete) of JIS A 5308.
5.4
Reinforcement Reinforcement bar shall comply with one of the following standards or have the same or higher-grade mechanical properties:
5.5
(1)
JIS G 3112
Steel Bars for Concrete Reinforcement
(2)
JIS G 3521
Hard Drawn Steel Wire
(3)
JIS G 3532
Iron Wires
(4)
JIS G 3538
Hard Drawn Steel Wire for Priestesses Concrete
(5)
JIS G 3551
Welded Steel Wire and Bar Fabrics
Admixture When admixture is used, it shall not have any harmful influence on the pipe. The use of fly ash, expansive agents, chemical admixtures, and corrosion inhibitors shall conform to the following: (1)
JIS A 6201 Fly Ash for use in Concrete
(2)
JIS A 6202 Expansive Additive for Concrete
(3)
JIS A 6204 Chemical Admixtures for Concrete
(4)
JIS A 6205 Corrosion Inhibitor for Reinforcing Steel in Concrete
9
5.6
Steel Materials Steel materials shall conform to SS400 under JIS G 3101 (Rolled Steels for General Structure), or SM400A under JIS G 3106 (Rolled Steels for Welded Structure).
5.7
Gaskets Gaskets for pipe jointing shall be functionally watertight and durable. In the case of using rubber gaskets, it shall conform to JIS K 6353 (Rubber Goods for Water Works); Class IV for Standard Pipes, and Class I - A60 for Intermediate Pipes.
6. MANUFACTURE 6.1
Measurement of Materials Materials for concrete shall be measured by mass. However, water and liquid admixtures may be measured by volume.
6.2
Chlorides Content Chloride ions (Cl―) present in fresh concrete shall not be higher than 0.30kg.m3.
6.3
Steel Collar Steel Collar shall be fabricated in accordance with JIS Z 3211 (Covered Electrodes for Mild Steel) or JIS Z 3312 (MAG Welding Solid Wires for Mild Steel and High Strength Steel). Welding shall be carried out by a qualified person, under JIS Z 3801 (Standard Qualification Procedure for Manual Welding Technique) or JIS Z 3841 (Standard Qualification Procedure for Semi-Automatic Welding Technique). Steel Collar shall be protected against corrosion by providing a coating in accordance with JIS K 5664 (Tar Epoxy Resin Paint), or a material having the same or a higher grade of performance. Anchors and Rubber Seal shall be provided on the embedded surface of the collar.
6.4
Forming Forming of the pipes shall be carried out by setting the pre-assembled steel cage in the metallic mould, casting the mixed concrete, and compacting under spinning, roller-pressing, or by vibration methods.
6.5
Curing Curing shall be conducted in a manner that will provide satisfactory results.
6.6
Gaskets Gaskets shall be fitted securely to the specified position of the joint portion of the pipe.
10
6.7
Intermediate Pipes Intermediate Pipes shall be fabricated and coated in accordance with Section 6.3. Forming of concrete to Intermediate Pipes shall be carried out in accordance with Section 6.4. However, for S-Type Intermediate Pipe, this shall be conducted by manual packing with concrete or mortar filling.
7. TESTING METHODS 7.1
External Loading Test External loading test shall be conducted on the pipe supported horizontally. Rubber pads (approximately 20mm thick) shall be inserted between the pipe surface and timber supports (approximately 150mm x 150mm). The bottom support may be omitted if appropriate. The load shall be applied vertically as shown in Figure 6, so that it is distributed fairly uniformly on the pipe body.
Figure 6: External Loading Test Load P
Load P Steel Beam Square Wood Rubber Plate
Steel Beam
Rubber Plate Square Wood
7.2
Compressive Strength Test of Concrete Compressive strength test of concrete shall be carried out in accordance with JIS A 1108 (Method of Test for Compressive Strength of Concrete), using solid cylindrical test specimens prepared in accordance with JIS A 1132 (Method of Making and Curing Concrete Specimens)
7.3 Water-tightness Test Water-tightness test for joint shall be carried out as shown in Figure 7. The 2 pipes shall be fully jointed (no pipe-pipe gap; 0mm extraction) and the joint portion is subjected to a flood of water, either internally or externally. The water pressure is applied in accordance with the joint specification requirement and maintained for 3 minutes.
11
Figure 7: Water-Tightness Test Pressurized Collar
Water Pressure Band
Water
Gasket Cushion Ring 0mm Extraction Length
8. INSPECTION METHOD 8.1
Inspection Items Inspection shall be made for appearance, shape, and dimensions of the pipes, and the external strength, concrete compressive strength, and water-tightness of the joint.
8.2
Appearance and Shape Inspection for appearance and shape shall be made for all quantity, and shall be passed in accordance with the requirements in Section 3.1 and 4.
8.3
Dimensions Inspection for dimensions shall be made on one pipe randomly selected from the specified lot, and the lot shall be passed in accordance with the requirements in Section 4. If the inspection does not result in a pass, the entire quantity shall be inspected, and each pipe shall be passed in accordance with the requirements in Section 4.
8.4
External Strength External strength shall be inspected for cracking load only. The inspection shall be made for one pipe randomly selected from the specified lot, and the lot shall be passed in accordance with the requirements in Section 7.1, if there is no crack exceeding 0.05mm in the pipe body. If the inspection does not result in a pass, a further two pipes shall be randomly selected from the same lot for the same inspection, and the lot (except the first failed pipe) shall be passed if both pipes are passed. If any of the two pipes do not pass in this stage, the entire lot shall be rejected.
12
8.5
Concrete Compressive Strength Concrete compressive strength shall be inspected for specimens representing the specified lot of pipes, and the lot shall be passed in accordance with the requirements for the compressive strength test in Section 7.2, if the specified strength is satisfied. If the inspection does not result in a pass, one pipe shall be randomly selected from the specified lot, and 3 or more cored samples shall be taken from the pipe. The cored samples shall be tested in accordance with JIS A 1107 (Method of Sampling and Testing for Compressive Strength of Drilled Cores of Concrete), and the lot shall be passed if the result of the test satisfies the requirement in Section 3.3.
8.6
Water-Tightness Water-tightness of the joint shall be inspected for 2 randomly selected pipes from the specified lot, and the lot shall be passed in accordance with the requirements in Section 7.3, if no leakage is indicated. If the inspection does not result in a pass, a further 2 set of pipes (total 4 pipes) shall be randomly selected from the same lot for the same inspection, and the lot (except the first failed set of pipes) shall be passed if both set of pipes are passed. If any of the two set of pipes do not pass in this stage, the entire lot shall be rejected.
9. PRODUCT DESIGNATION The pipes shall be designated by class, nominal diameter, and effective length (mm) in accordance with Table 1.
10. MARKING The pipes shall be clearly marked with the following particulars: (1) Product designation (2) Name of pipe or its abbreviation (3) Manufacturer’s name or its abbreviation (4) Factory name or its abbreviation (5) Date of forming
QUOTED STANDARDS:
JIS A 1107
Method of Sampling and Testing for Compressive Strength of Drilled Cores of Concrete
JIS A 1108
Method of Test for Compressive Strength of Concrete
JIS A 1132
Method of Making and Curing Concrete Specimens
JIS A 5308
Ready-Mixed Concrete
13
JIS A 6201
Fly Ash for use in Concrete
JIS A 6202
Expansive Additive for Concrete
JIS A 6204
Chemical Admixtures for Concrete
JIS A 6205
Corrosion Inhibitor for Reinforcing Steel in Concrete
JIS B 2301
Screwed Type Malleable Cast Iron Pipe Fittings
JIS B 2302
Screwed Type Steel Pipe Fittings
JIS G 3101
Rolled Steels for General Structure
JIS G 3106
Rolled Steels for Welded Structure
JIS G 3112
Steel Bars for Concrete Reinforcement
JIS G 3452
Carbon Steel Pipes for Ordinary Piping
JIS G 3521
Hard Drawn Steel Wire
JIS G 3532
Iron Wires
JIS G 3538
Hard Drawn Steel Wire for Prestressed Concrete
JIS G 3551
Welded Steel Wire and Bar Fabrics
JIS K 5664
Tar Epoxy Resin Paint
JIS K 6353
Rubber Goods for Water Works
JIS R 5210
Portland Cement
JIS R 5211
Portland Blast-Furnace Slag Cement
JIS R 5212
Portland Pozzolan Cement
JIS R 5213
Portland Fly-Ash Cement
JIS Z 3211
Covered Electrodes for Mild Steel
JIS Z 3312
MAG Welding Solid Wires for Mild Steel and High Strength Steel
JIS Z 3801
Standard Qualification Procedure for Manual Welding Technique
JIS Z 3841
Standard Qualification Procedure for Semi-Automatic Welding Technique
RELATED STANDARDS:
JIS A 5303
Reinforced Spun Concrete Pipes
JIS Z 8203
SI Units and Recommendations for the Use of their Multiples and of Certain Other Units
JIS Z 8401
Guide to the Rounding of Numbers
JSWAS A-1
Reinforced Concrete Pipes for Sewerage
JSWAS A-6
Jacking Small-Diameter Reinforced Concrete Pipes for Sewerage
14
JSWAS A-2 – 1999
Jacking Reinforced Concrete Pipes for Sewerage Commentaries This Standard specifies the requirements for reinforced concrete pipes for sewerage, which are installed by the jacking method.
This Standard was first established in 1973, and numerous revisions has been made thereafter. The initial versions have specified in detail the requirements for the joint shape and dimensions. However, over the years, the technology related to the jacking methods have developed significantly, such as long-distance jacking, curved jacking, and numerous techniques to answer to all types of soil conditions. In response to such developments, improvements have been made to the pipes, including various designs of joints.
Under such circumstances, and in awareness of the trend in international standards, this revision has been made on the basis of performance criteria. In this respect, there is a major change in the regulatory methods. Even so, aspects such as internal diameter, thickness, and effective length has remained the same as standard dimensions, in consideration of the existing jacking equipments.
The pipes are classified into the Standard Pipe and Intermediate Jacking Pipes (hereinafter “Intermediate Pipes”), and further subclassified into “50” or “70” for concrete compressive strength of pipe, Class “1” or “2” for external strength, and JA, JB, or JC for joint specification. The range of specified nominal diameters have remained the same, with Standard Pipe as 800~3000mm, and Intermediate Pipe as 1000~3000mm.
1. SCOPE The pipes to which this Standard applies are those factory-manufactured by centrifugal force (spinning method), roller-pressing method utilizing round-section rotation bars to compact the surface of the concrete, and vibration method. These pipes shall satisfy all the requirements as set forth in this Standard.
2. CLASSIFICATION The type of the pipes comprise the generally used Standard Pipe, and that which are used for part-way jacking; Intermediate Pipes. The range of specified nominal diameters have remained the same, with Standard Pipe as 800~3000mm, and Intermediate Pipe as 1000~3000mm.
In order to suit the external loading requirements that generally differ in accordance with the depth of the installation, Class 1 and Class 2 designs are available. Class 2 is designed to accommodate
15
double the cracking load of Class 1 pipes.
Type-S Intermediate Pipe is not sub-classified (to Class 1 or 2) owing to it steel-pipe nature. Type-T Intermediate Pipe is a steel-and-concrete composite structure, and classified into Class 1 and Class 2, in a similar manner as Standard Pipes.
In addition, the compressive strength of concrete for the pipe is available as “50” and “70”. Class 1 Standard Pipe is made available for both strength levels.
“50” refers to the compressive strength
of concrete of the pipe: minimum 50N/mm2, and corresponds to the formerly-recognized minimum 500kgf/cm2. Similarly, “70” refers to minimum 70N/mm2 (formerly minimum 700kgf/cm2).
Furthermore, this revision includes for the first time the requirements for the joint performance. This has been necessary in view of the increasing jacking pipe works at great depths and consequently the necessity to respond to higher groundwater pressures. A larger extraction-length at the joint has also become necessary due to tighter curve-jacking. Section 3.4 details the requirements for joint performance.
Class 2 – 70 for Standard Pipe is not specified owing to the fact that it is not commonly required, as well as for the higher level of production technology required to manufacture this type of pipe. Intermediate Pipe Class 1 – 70 is also not specified owing to installation reasons related to the intermediate jacking capacity and its arrangements.
3. QUALITY The former Section 3.4 “Water Tightness” has been changed to “Joint Performance”, wherein water pressure resistance and extraction length are specified.
3.1
Appearance “Detrimental flaws” shall refer to aspects that will adversely affect the functional strength of the pipe, water-tightness, and durability. The internal surface of the pipe shall not have rough nesses that will impede the flow. However, it is not necessary to provide additional finish (such as cement paste) to make the surface particularly smooth.
3.2
External Strength External strength values are unchanged. Cracking strength for Class 2 is 2 times that for Class 1. Breaking strength is 1.5 times the cracking strength.
External strength is not applicable for Type-S Intermediate Pipe owing to its steel material nature. However, cracking strength is applicable for Type-T Intermediate Pipe as it is a
16
steel-and-concrete composite design.
3.3
Concrete Compressive Strength of Pipe This section has formerly been titled “Concrete Compressive Strength”. This revision is made due to the fact that it is the strength of the concrete in the pipe body that is the subject of the quality characteristic. This is confirmed by the inspection requirements described in Section 8.5 “Concrete Compressive Strength”. As previously specified, the concrete compressive strength of pipe are minimum 50N/mm2 (minimum 500kgf/cm2) and minimum 70N/mm2 (minimum 700kgf/cm2). In principle, the axial bearing capacity of the pipe is calculated based on these strength values.
In consideration of the differing concrete mix and curing methods depending on the manufacturing factory, the concrete compressive strength shall refer to the age at the point of product delivery.
3.4
Joint Performance Joint performance is categorized into JA, JB, and JC (3 types), for which water pressure resistance and extraction lengths has been specified.
It has been common in the past to require water pressure resistance of 0.1 MPa for jacking pipes, but owing to the increasing requirement for higher pressure performance, requirements for 0.2 MPa has been specified in this Standard.
“Extraction length” shall refer to the gap between the jointed pipes. Along with the increasing distance of jacking installation and related imposition of various conditions, tight-curved jacking are also becoming common. Under tight-curved jacking, since the gap of the joint occurring at the outer circumference of the pipes are made even wider, such gaps need to be specified as extraction lengths.
Further, in order to confirm the performance of the joint for earthquake resistance, the Joint Model Test Regulation includes the requirements for composite water-tightness test, in which extraction lengths are indicated for Level 2 earthquake conditions. The objective of this test is to confirm the water tightness of the joint, and that the internal flow is maintained, in a curve-jacking arrangement under Level 2 earthquake conditions; the essential point being the additional extraction at the joint expected under such seismic situations. The details of this test is as prescribed in “ Principles Related to Earthquake Resistance for Sewerage Facilities, and Commentaries”. 2 pipes are jointed normally, after which a deflection is introduced. The
17
joint gap at the internal circumference of the deflection is extracted to a length of 37mm (“earthquake-situation extraction length”). The joint gap at the external circumference of the curve is positioned to the basic curve-jacking extraction length + earthquake-situation extraction length. The testing apparatus is fitted to the outer line of the joint, water is applied to the specified pressure, and visual inspection for leakages is conducted. 37mm is the extraction length for each pipe with the assumption of 1.5% of permanent strain in the soil under earthquake situation ( 2430mm x 0.015). [Refer to Appendix 1 “Joint Model Test Regulations”; ”Test Method”].
The values for water pressure resistances and extraction lengths have been determined in consideration of performance tests and actual installations.
4. SHAPE, DIMENSIONS, AND DIMENSIONAL TOLERANCES In relation to the performance-based modification of the Standard, the imposing of requirements for pipe shape and dimensions have been restricted to the minimum, while fundamental design and installation-related aspects such as internal diameter, thickness, and effective length, are specified accordingly.
In consideration of pipe-end face protection and stress distribution of the jacking force, the use of cushion material is also specified.
4.1
Joint Structure This is a newly introduced section to the Standard. Joint structure shall be of such design that is confirmed under the Joint Model Test Regulation. The detailed shape, dimensions, and dimensional tolerances of the joint shall be in accordance with the approved design of the pipes.
Changes to joint designs that are already established shall be subjected to the approval of Japan Sewerage Works Association.
“Additional fabrication that will not affect the shape or strength of the pipes” refers to the provision of bevels at the edge of the pipe (for safer demoulding work), and guide-grooves for proper positioning of gaskets.
4.2
Standard Pipe The most commonly used jacking pipe is referred to in this Standard. The shape, dimensions, and dimensional tolerances are as given in Figure 1. Pipe ends are described as socket and spigot, with the socket having the pre-embedded steel collar design.
18
Requirements are specified for 4 dimensions; namely, Internal Diameter (D), Thickness (T), Effective Length (L), and Joint Minimum Thickness (t). Internal diameter, thickness, and effective length are basic dimensions, and tolerances have been assigned to each. Joint minimum thickness is specified in order to calculate the axial loading capacity from the effective section area, based on such standardized dimension.
Pre-embedded locking sockets are included in the notes, as in previous revisions. Shape, dimensions, and locations of this item is further detailed in Reference Document No. 6.
4.3
Intermediate Pipes The Type-S and Type-T Intermediate Pipes compose the set of Intermediate Jacking Pipes, which is used to thrust the pipes installed ahead of it with the expansion-and-contraction action of hydraulic jacks. The length of the combined Type-S and Type-T Intermediate Pipes is designed such that it does not exceed the length of the Standard Pipe when the stroke of the jacks is at maximum. This is necessary since the joint between the Type-S and Type-T Intermediate Pipes does not accommodate deflections, and will impede the jacking process if the length is longer than the Standard Pipe.
Moreover, the length of the collar for the Type-S Intermediate Pipe needs to be of a length that will not allow dislocation from the gasket of the Type-T Intermediate Pipe when the jacks are fully extended. It is also necessary that the Type-T Intermediate Pipe has an extra margin of shaft length to cover the slack length when the jacks and the Support Ring are removed at the final stage of the intermediate jacking process.
From considerations described above, requirements for Type-S Intermediate Pipes are specified for 4 dimensions; namely, Pipe Internal Diameter (D), Collar Internal Diameter (Dc), Length (Lc), and Thickness (tc). Requirements for Type-T Intermediate Pipes are specified for 4 dimensions; namely, Pipe Internal Diameter (D), Shaft External Diameter (D1), Shell Thickness (t2), and Effective Length (LT).
In relation to the setting of these dimensions, the capacities of the jacks and their dimensions, and the thickness of the Support Rings are as given in Table 4. The arrangement is as shown in Figure 8.
19
Table 4: Jack Details and Support Ring Thickness (Unit: mm) Jack
Support
Nominal Thrust Force
Diameter
kN (tf) 1000 ~ 1200
295
(30)
1350 ~ 2200
490
(50)
2400 ~ 3000
980
(100)
Ring Stroke
External Dia.
Length
135
525
70
165
550
82
225
580
94
300
Thickness
Note: Above values are maximum, in consideration of different manufacturers’ dimensions available
Figure 8: Sample Arrangement of Intermediate Pipes with Support Ring and Cushion Ring
Gasket for Standard Pipe
Gaskets for
Type-S
Jacking
Intermediate Pipe
Direction
Cushion Ring Standard Pipe
Intermediate Pipe
Type-T Intermediate Pipe
Lubricant Inlet Intermediate
Cushion Ring
Standard Pipe
Cushion Ring
Jacks
In order to minimize the friction occurring at the gaskets during the sliding movements, lubricant inlets are provided at 4 locations along the circumference of the Type-T Intermediate Pipe.
The Internal Diameter of Type-S Intermediate Pipe is designed to be slightly larger than the Internal Diameter of the Standard Pipe. This portion is filled with in-situ mortar at the end of the jacking installation.
4.4
Grouting Socket Formerly, Grouting Sockets have been specified in detail for material, shape and dimensions. A broader specification for socket and plug is made in this revision.
Quality and designation requirements of socket and plug are unchanged from previous versions. The use of alternatives that have the same or higher functional properties has been allowed in this revision. 20
4.5
Joint Groove Formerly, Joint Groove has been specified in detail for dimensions. This revision has been revised to specify only the requirement for shape.
4.6
Lubricant Inlet Formerly, Lubricant Inlet have been specified in detail for shape and dimensions. This revision has been revised to specify only the requirements for the steel tube, socket and plug. Quality and designation requirements of steel tube, socket and plug are unchanged from previous versions. The use of alternatives that have the same or higher functional properties has been allowed in this revision.
5. MATERIALS 5.1
Cement There are no revisions in this Section.
5.2
Aggregates The requirement to conform to Appendix 1 of JIS A 5308 has been added. In the case of employing aggregates evaluated as “Category B” under the requirements in Appendix 1 of JIS A 5308, corrective measures against alkali-aggregate reactivity shall be taken in accordance with requirements given in Sections 3, 4, and 5 of Appendix 6.
5.3
Water The requirement to conform to Appendix 9 of JIS A 5308 has been added.
5.4
Reinforcement There are no revisions in this Section. In the case of employing alternatives “having the same of higher grade”, it is necessary to conduct tests to confirm the tensile strength of the material.
5.5
Admixture There are no revisions in this Section.
5.6
Steel Materials There are no revisions in this Section.
21
5.7
Gaskets There are no revisions in this Section. In the case of using rubber gaskets, it shall conform to JIS K 6353; Class IV for Standard Pipes, and Class I - A60 for Intermediate Pipes (in consideration for additional friction).
6. MANUFACTURE 6.1
Measurement of Materials There are no revisions in this Section.
6.2
Chlorides Content In consistency with other standards, Chloride ions (Cl―) present in fresh concrete shall not be higher than 0.30kg.m3.
6.3
Steel Collar No change has been made in this Section. However, the reference to the provision of an anchor mechanism to the embedded item has been made in consideration of the various forms of anchors being developed.
6.4
Forming There are no revisions in this Section.
6.5
Curing This Section has been modified, with the deletion of the reference to high-temperature and moisture requirement after demoulding (in the case of using expansive admixtures). The commonly used method of steam curing is as follows: (1)
Placing of pipe in curing chamber while still in mould.
(2)
Steam curing to be started after a minimum of 2 hours from the time of concrete mixing.
(3)
Temperature elevation to be not higher than at the rate of 20 degrees Centigrade per hour, with the maximum temperature of around 65 to 75 degrees Centigrade.
(4)
Mould to be removed from the curing chamber only after the temperature is close to ambient temperature.
6.6
Gaskets There are no revisions in this Section.
6.7
Intermediate Pipes There are no revisions in this Section.
22
7. TESTING METHODS 7.1
External Loading Test There are no revisions in this Section. Supports used for this test shall be straight timber or composite-wood material (eg. plywood) that are sufficiently rigid to bear the test loads. Rubber pads shall be of sufficient hardness (about Hs = 60).
With respect to the loading until cracking load, this may be conducted at any suitable rate up to half of the specified load. For the second half, uniform loading at the rate of 10kN/m per minute shall be applied. In order to estimate the timing of the occurrence of cracks, the use of dial gauges to observe the deformation of the pipe accompanying the applied loads is recommended.
7.2
Compressive Strength Test of Concrete Compressive strength test of concrete shall be carried out with solid cylindrical specimens prepared in accordance with JIS A 1132. The previous reference to the testing in accordance with JIS A 1136 (Method of Test for Compressive Strength of Spun Concrete) has been deleted.
In relation to the various jacking methods, the axial bearing capacity of the pipe is very important. However, since it is not possible to directly verify this using the product itself, this is checked indirectly with the solid cylindrical specimens. There is sufficient correlation between the concrete of the pipe body and the specimen, and although the specimen is used for control purposes, it is necessary to confirm this correlation by testing both the specimen and the pipe.
7.3
Water-tightness Test Water-tightness test shall be carried out on the joint of 2 pipes fully attached, with 0mm extraction length. Water is introduced to the external or internal line of the joint, and water pressure is applied in accordance with the joint specification requirement. Joint performances required are 0.1MPa for “JA”, and 0.2MPa for “JB” and “JC”. It is necessary to note that since the pipes are not normally subjected to full flow in the case of sewerage pipelines, the design is made primarily in consideration of the external water pressure during and after installation of the pipeline. In this respect, the test with the application of water pressure at the external line of the joint is more appropriate. However, since there has been no problems reported with pipes installed which have been tested at the internal line of the joint, the two test methods are both approved for the time being. In the future, only the external test may be specified as the requirement.
23
8. INSPECTION METHOD The requirements in this Section applies only to the inspection of quality, shape, and dimensions of the pipe during the manufacturing process. With respect to inspection at delivery, the requirements may be agreed among the concerned parties in addition to or separate from those that have been established by this Association.
8.1
Inspection Items There are no revisions in this Section.
8.2
Appearance and Shape There are no revisions in this Section. “Detrimental flaws” mentioned in Section 3.1 refers to conditions given below: For pipe body; (1)
Cracks in pipe body. However, very thin surface cracks related to drying shrinkage are permissible.
(2)
Damage to 3% or more of pipe end surface.
(3)
Cavity or aggregates exposure to 5% or more of pipe external surface.
(4)
Surface stains caused by reinforcement.
For steel collar: (5)
Deformations that may adversely affect the water-tightness of the joint.
In addition, “smooth” shall refer to the absence of: exposed coarse aggregates, any voids due to dislodged coarse aggregate, and excessively rough finished surfaces.
8.3
Dimensions There are no revisions in this Section. For the measurement of internal diameter and thickness of the pipe, these shall be inspected on both ends of the pipe at the four points made by the right-angled intersection of 2 random lines placed at the ends of the pipe. Effective length of the pipe shall be measured at the left and right sides of the internal surface.
Thickness (T) shall be measured using calipers at about 150 to 200mm from the edge of the pipe.
Inspection shall be made for 1 pipe randomly selected from 1 lot of pipes, for each size. The quantity of pipes per 1 lot shall be as given in Table 5. If the inspection does not result in a pass, the entire quantity shall be inspected, and each pipe shall be passed individually in accordance with the requirements.
24
Since D, T, and L are critical dimensions, these are recommended to be inspected for each pipe at demoulding, with the use of limit gauges. Intermediate Pipes are generally inspected for all quantity.
Table 5: Quantity of One Lot
8.4
Nominal Diameter
Quantity of One Lot
800 ~ 1000
200 Pcs
1100 ~ 1800
150 Pcs
2000 ~ 3000
100 Pcs
External Strength As required in previous versions, external strength is inspected only for cracking strength. Breaking strength test is not conducted owing to the following reasons, but whenever there is a change in the design specifications, this test is necessary to confirm the performance of the pipe. (1)
Breaking strength is determined by the reinforcement design, which can be verified during the manufacturing process control.
(2)
Previous test results confirm that pipes which pass the cracking strength test also pass the breaking strength test.
Inspection shall be made for 1 pipe randomly selected from 1 lot of pipes, for each size, and Class 1-50, Class 1-70, and Class 2-50. The quantity of pipes per 1 lot shall be as given in Table 5. This “quantity of pipes per 1 lot” refers to the situation of the pipes being produced consecutively, and therefore the frequency of the test will have to be determined in consideration of the actual production situation.
For Type-T Intermediate Pipe, the inspection is generally carried out for Class 1 and Class 2 as separate lots, for sizes ranging from 1000 to 3000mm. The size of each lot is about 20 pieces.
8.5
Concrete Compressive Strength There are no revisions in this Section. “Specimens representing the specified lot of pipes” shall refer to samples collected at least once daily, per concrete mix design. Tests are carried out for the specified age in accordance with Section 7.2, and shall be passed if the specified strength is satisfied. “Specified age” shall refer to the age of the concrete as established under the quality control program, and “specified strength” shall refer to the compressive strength as established under the same quality control program.
25
In consideration of the difficulty in maintaining large quantities of specimens for repeated testing, requirements for re-inspection is specified so that core samples may be extracted from the pipe body for compressive strength tests.
8.6
Water-Tightness of Joint The water-tightness of the joint is guaranteed if the shape and dimensions are in accordance with the specification. This test is conducted for each size-group of pipes as one lot, produced within a specified period, and which have the same dimension (and tolerance) of opening between the socket and spigot diameters.
This size-group of pipes and the frequency of the test required are normally as given in Table 6.
Table 6: Test Frequency for Water-Tightness of Joint Standard Pipe
Intermediate Pipe
Nom. Dia.
Frequency of Test
Nom. Dia.
Frequency of Test
Size-Group
(every:)
Size-Group
(every:)
800 ~ 1200
6 months
1350 ~ 2200
6 months
1000 ~ 3000
12 months
2400 ~ 3000
12 months
9. PRODUCT DESIGNATION Examples are as follows.
Standard Pipe; Class 1-70; JA; Nominal Dia. 1000; Effective Length 2430mm is marked as: JA71 – 1000 x 2430 Standard Pipe; Class 2-50; JB; Nominal Dia. 1500; Effective Length 1200mm is marked as: JB52 – 1500 x 1200 Intermediate Pipe; Type-S; JC; Nominal Dia. 2000; Effective Length L mm is marked as: JCS 2000 x L Intermediate Pipe; Type-T; Class 1-50; JA; Nominal Dia. 1800; Effective Length 1200mm is marked as:
JAT51 – 1800 x 1200
10. MARKING “Name of pipe or its abbreviation” has been added in this revision. “Date of forming” shall refer to the date of casting the concrete.
26
Appendix 1
Joint Model Test Regulation 1. SCOPE This Regulation specifies the requirements for the tests to be conducted to verify the water-tightness of the joint of Jacking Reinforced Concrete Pipes for Sewerage that are manufactured in accordance with JSWAS A-2 (hereafter “A-2”).
2. TEST ITEM 2.1
Test Pipe In principle, the test shall be conducted with 2 pipes of the size from the smallest of the size-group. However, if there are numerous types of the same size, the test shall be carried out for the smallest pipe size of each type.
The joint of the pipes to be tested shall be that combined part of the socket and spigot where the gasket shall be subjected to its minimum compression.
The length of the pipes shall be in accordance with the requirement for testing, and a cushion material (ring) of 10mm shall be attached.
As necessary, insofar as the joint design is not affected, modification work may be performed on the pipes to accommodate the test apparatus.
2.2
Gasket The gasket shall be of such height that it will be at its minimum compression rate when the pipes are jointed.
2.3
Measuring of Dimensions The measuring of dimensions for the pipes and gaskets shall be conducted before the test.
2.4
Quality The quality of the pipes and the gasket shall satisfy the requirements as given in A-2.
2.5
Installation of Gasket The gasket shall be fitted securely to the pipe prior to the testing of the pipe joint.
27
3. TEST METHOD 3.1
Test Apparatus Equipments and apparatus for the test shall be designed so as not to cause any adverse effects to the joint performance.
3.2
Test Method The test to confirm the water-tightness of the joint shall be conducted in accordance with the categorization as given in Table 7. The 2 connected pipes shall be subjected to horizontal test, bending test, and horizontal-bending combination tests (hereafter “combination test”) with the apparatus designed to exert water pressure at the external line of the joint. Each specified water pressure is maintained for 3 minutes. The jointed pipes may be positioned either vertically or horizontally.
Examples of the water-tightness test method are as shown in Figures 9 to 11. An example of the water-tightness test apparatus is as shown in Figure 12.
Table 7: Test Details Category
Test Type
Test Pressure
Extraction Length
(Mpa)
(mm)
Horizontal Test
30 0.15
JA
Bending Test
45
Combination Test
0.10
Horizontal Test
67 40
0.25 JB
Bending Test
60
Combination Test
0.20
Horizontal Test
77 60
0.25 JC
Bending Test
90
Combination Test
0.20
28
97
(1)
Horizontal Water-Tightness Test The test pipes are arranged in a straight line, having the specified extraction lengths at the joint. An example of the horizontal water-tightness test arrangement is as shown in Figure 9.
Figure 9: Example of horizontal water-tightness test arrangement Securing Band
Water Pressure Test Apparatus
Extraction Length Gauge
Lever Block
Test Extraction Length
(2)
Wire Rope
Bending Water-Tightness Test One test pipe is securely fixed, and the other test pipe is moved until the specified deflection is obtained with the required test extraction length. An example of the bending water-tightness test arrangement is as shown in Figure 10.
Figure 10: Example of bending water-tightness test arrangement
Water Pressure Test Apparatus
Test Extraction Length Jack
29
(3)
Combination Water-Tightness Test One side of the joint is extracted (vertically or horizontally) to 37mm, and the opposite side of the joint is extracted further to the specified test extraction length. An example of the combination water-tightness test is as shown in Figure 11.
Figure 11: Example of combination water-tightness test
Water Pressure Test Apparatus
Test Extraction Length Jack
Figure 12: Example of water-tightness test apparatus Water Pressure Steel Collar
Pressurized Water
Band
Expansive Seal
Gasket Cushion Ring
Anchors Extraction Length
30
Tying Bolt
3.3
Measurement of Test Extraction Length The test extraction length is determined in advance as a relation between the dimensions of the openings at the outer and inner line of the joint, as illustrated in Figure 13.
Figure 13: Measurement of Test Extraction Length Extraction Length at External Side of Joint
Extraction Length at Internal Side of Joint
3.4
Test Procedure The water-tightness test is conducted with the same pair of test pipes, in the sequence of horizontal, bending, and combination tests. Confirmation of the test water pressure and test extraction lengths shall be made after checking for leakages in accordance with the A-2 requirements.
3.5
Verification of Test Pipes and Test Conditions Validation by the Japan Sewerage Works Association requires the verification of the quality and dimensions of the test pipes by Test Result Report, and verification by actual observation of the water-tightness tests.
4. ACCEPTANCE CRITERIA The joint performance of the test pipes shall be judged to be in conformance and accepted as satisfying the required performance under A-2 if the test is conducted in accordance with Sections 2 and 3, and no leakage from the joint is observed.
5. REJECTION CASE In the event that the test results in a rejection, re-testing is not acceptable in principle for the same joint design and gasket for the same category.
31
Appendix 1
Joint Model Test Regulations Commentaries This regulation is established for the conducting of tests to verify the acceptability of the various joint performance of reinforced concrete pipe as required under the A-2 specification.
1.
SCOPE The tests established herein are for the confirmation of the performance of joints, and are collectively categorized in the quality control scheme as water-tightness tests for joints.
2. TEST ITEM 2.1
Test Pipe; 2.2 Gaskets Rubber rings are most commonly used. On this basis, the water-tightness of the joint is largely influenced by the compression rate of the rubber ring. When the compression rate of the rubber ring is at its minimum, the water-tightness of the joint is lowest. Therefore, the dimensions of the test pipe joint is established such that the compression rate is to be at its minimum within the tolerances.
Accordingly, the height of the rubber ring is established so as to provide the minimum compression rate when jointed.
In view of the difficulty in arranging the test pipe and gasket so as to precisely obtain the limit condition within the tolerances, it is permissible to adopt the average value of the joint dimension, and to obtain the minimum compression rate with the estimated height of the rubber ring.
In addition, since the deflection angle is larger for smaller nominal diameter of the pipe under the condition of fixed extraction length, the smallest size of pipe for the size-group is adopted for the tests.
Lastly, modification work to the pipe that will not influence the performance of the joint; such as the installation of inserts near the joint location, is permitted to accommodate the efficient conducting of the various tests.
32
2.3
Measuring of Dimensions The measuring of dimensions for the pipe joint and gaskets shall be conducted before the test. This is necessary as it will not be possible to measure the gasket-seat dimension of the pipe afterwards, and since it is common to use adhesives for the attachment of gaskets.
2.4 Quality As stated.
2.5 Installation of Gasket In order to provide the proper water-tightness of the joint, the gasket should naturally be attached at the specified location, and should not shift when the pipes are jointed. As it is common to use adhesives to attach the gasket to the spigot or to the collar, this should be carried out in a timely manner before the jointing of pipes for the tests.
3. TEST METHOD 3.1
Test Apparatus Equipments and apparatus shall be designed so that they will reliably confirm the performance of the test pipe. Additional attention shall be given to the fact that they should withstand the movement of the test pipes; and at the same time to not cause adverse influence, when the pipes are arranged for bending and extraction at the joints.
3.2
Test Method Three tests; namely, horizontal, bending and combination tests, are established to confirm the water-tightness of the joint.
The 3-minutes holding period for the water pressure is applicable regardless of the material of the gasket. For example, this shall also apply in the case of water-expansive rubber rings. The requirements for the performance of the joint under A-2 are extraction length and water pressure resistance. Table 7 is established to satisfy such requirements. It should be noted that 0.05MPa has been added to the required pressure for horizontal and bending tests, which are the arrangement inferred for a normal-condition, and the values shown for the combination test are for the situation under a level-2 earthquake condition.
Regarding extraction lengths, the specified value applies for the horizontal test, and the specified value is multiplied by 1.5 for the bending test, in consideration of installation-time errors.
33
For the combination test, the additional required extraction length is derived by considering the factor of 1.5% to the length of the Standard Pipe as permanent strain in the soil under earthquake situation ( 2430mm x 0.015 = 37mm).
3.3
Measurement of Test Extraction Length Required extraction length as specified in A-2 is the dimension at the external side of the joint. Since it is not possible to directly measure this during the test, the guideline in this section is provided to determine this dimension by measuring first the internal side of the joint.
3.4
Test Procedure The 3 tests are to be conducted with the same pair of test pipes in view to verifying the condition of the attachment of the gasket at the joint under deflection situations.
4
ACCEPTANCE CRITERIA Attention is drawn to the strict conformance to this Standard whereby the test result is acceptable by observation for leakages at the joint.
5
REJECTION CASE In the event that the tests result in a rejection despite the conducting of the test with test components in conformance with the specified qualities, the joint design is judged to be defective, and a re-test is not acceptable in principle.
This course of action is reasonable in view of the expectation that numerous prior tests would already have been conducted in the course of developing such joint design.
However, a re-test is permissible in the case that the Japan Sewerage Works Association is in agreement that the source of the failure is not attributed to the joint design.
34
Appendix 2
Registered Pipe Designs The pipes that are registered with the confirmation of joint performance in accordance with Appendix 1 (Joint Model Test Regulations) are as given in Table 8. Table 8: Registered Pipe Designs
Joint
Regist-
Registra-
Designation of
Code
Perfor-
ration
tion Date
Pipe
mance
No.
JA
JA1
1 Nov. 1999
Type E Pipe
JA
JA2
1 Nov. 1999
HJP
HJP
KHK S-1
Kinki Hume Pipe Co-op.
JB
JB1
1 Nov. 1999
W-Joint Pipe
EW
JWPAS J-2
W-Joint Pipe Assoc.
JC
JC1
1 Nov. 1999
NS Jacking Pipe
NS
JHPAS-25
Hume Pipe Assoc.
JC
JC2
1 Nov. 1999
W-Joint Pipe
JWJPAS J-2N
W-Joint Pipe Assoc.
E
ENW
Standard
JSWAS A-2-1991
II. JA JOINT SPECIFICATION
I-I
TYPE E PIPE
1. REGISTRATION
(1)
Registrant
(2)
Joint performance
JA
(3)
Registration No.
JA1
(4)
Registration date
1 November, 1999
(5)
Officialization of standard
1 April, 1991
(6)
Standard designation
JSWAS A-2-1991
35
Applicant
2. CLASSIFICATION
The classification of pipes are as described in Table 9. Table 9: Pipe Designs
Type
Shape
Standard Pipe
Intermediate Pipe
External
Compressive
Joint
Strength
Strength
Specification
Class 1
of Type
50
JA 51
70
JA 71
Class 2
50
-
-
Class 1
50
JAT51
Class 2
50
JAT52
S T
Designation
JA
Applicable Pipe Size (nominal)
800~3000
JA 52 JAS 1000~3000
3. SHAPE, DIMENSIONS AND DIMENSIONAL TOLERANCES OF PIPE
The shape, dimensions, and dimensional tolerances for Standard Pipe and Intermediate Jacking Pipe are as given in Figures 14~16.
3.1
Standard Pipe The shape, dimensions, and dimensional tolerances for Standard Pipe is as given in Figure 14.
Figure 14: Shape, Dimensions and Dimensional Tolerances of Standard Pipe (Unit: mm) Grout Sockets
Steel Collar
Grout Sockets
36
Figure 14: (Continued)
Joint Details Steel Collar
Embedded Rubber Seal Anchors Cushion Ring
Gasket Joint Groove
“a” Details
(Unit: mm) N o m in a l
In t. D ia .
D ia .
D
800
800 4
933
900
900 6
1053
1000
1000 6
1173
1100
1100 6
1283
1200
1200 6
1403
1350
1350 8
1563
1500
1500 8
1743
1650
1650 8
1913
1800
1800 10
2083
2000
2000 10
2313
2200
2200 10
2543
2400
2400 12
2763
2600
2600 12
2993
2800
2800 12
3223
3000
3000 12
3453
D1 + + + + + + + + + + + + + + + -
3 2 3 2 3 2 3 2 3 2 4 3 4 3 4 3 4 3 4 3 4 3 5 3 5 3 5 3 5 3
T h ic k n e s s
E ff. L e n g th
T
L
D 1
D2
2931 3
942
80
3308 3
1062
90
3685 3
1182
100
4031 3
1292
105
4408 3
1412
115
4910 6
1577
125
5476 6
1757
140
6010 6
1927
150
6544 6
2097
160
7267 6
2327
175
7989 6
2557
190
8680 9
2779
205
9403 9
3009
220
10125 9
3239
235
10848 9
3469
250
37
+ + + + + + + + + + + + + + + -
4 2 6 3 6 3 6 3 6 3 8 4 8 4 8 4 10 5 10 5 10 5 12 6 12 6 12 6 12 6
2430
132 ± 2
60
72
152 ± 2
70
82
+ 10 - 5
Figure 14: (Continued) (Unit: mm) N o m in a l D ia
L c
1
L c
2
L c
T c
D c
(D
c
+ 2T c )
800
951
3016
3
900
1071
3393
3
1191
3770
3
1100
1301
4115
3
1200
1421
4492
3
1588
5027
5
1768
5592
5
1938
6126
5
1800
2108
6660
5
2000
2338
7383
5
2200
2568
8105
5
2400
2792
8828
5
3022
9550
5
3252
10273
5
3482
10996
5
1000
1350
4 .5
120
130 ± 2
250
+ 5 - 2
1500 1650 6
2600 150 2800
152 ± 2
300
+ 5 - 2
9
3000
Notes: 10
1. The effective length of standard pipe (L) may also be 1200 5
10
2. The steel collar may be omitted for standard pipe. The effective lengths of the pipes may be: 2430 20 or 10
1200 20
3. The difference of maximum and minimum measurements of effective length shall be within 3mm. 4. For pipes 1000mm and larger, pre-embedded locking sockets (for pipe-pipe connection) may be installed. 5. The positions and quantity of grout holes may be altered as necessary.
38
3.2
Intermediate Pipes The combined lengths of Type-S and Type-T Intermediate Pipes are as given in Table 10. The shape, dimensions, and dimensional tolerances are as given in Figures 15~16.
Table 10: Combination of Type-S and Type-T Intermediate Pipes (Unit: mm) N o m in a l
E ffe c tiv e L e n g th o f S
E ffe c tiv e L e n g th o f T
C o m b in e d
D ia m e t e r
LS
LT
L e n g th
1000 150
1310
1100
1150
1200 1350
1315 155 1365
1500 1650 1200 1800 160
1370
2000 2200 2400 2600 180
1250
2800 3000
39
1440
Figure 15: Shape, Dimensions and Dimensional Tolerances of Type-S Intermediate Pipe
Section View Rib t x n Concrete or mortar
Concrete or mortar
“a” Details
“b” Details
In-Situ mortar finish Gasket for Standard Pipe
(Unit: mm) Nominal Int. Dia. Dia. 1000
D 1000
Eff. Lgth. DS
D1
1024 1173
1100
1100
1124 1283
1200
1200
1224 1403
1350
1350
1374 1563
1500
1500
1524 1743
1650
1650
1674 1913
1800 2000
1800 2000
1824 2083 2024 2313
2200
2200
2224 2543
2400
2400
2424 2763
2600
2600
2624 2993
2800
2800
2824 3223
3000
3000
3024 3453
+3 - 2 +3 - 2 +3 - 2 +4 - 3 +4 - 3 +4 - 3 +4 - 3 +4 - 3 +4 - 3 +5 - 3 +5 - 3 +5 - 3 +5 - 3
D1
DC
DC+2t C)
3685 3
1182
3770 3
4031 3
1292
4115 3
4408 3
1406
4492 3
4910 6
1576
5027 5
5476 6
1756
5592 5
6010 6
1926
6126 5
6544 6 7267 6
2096 2326
LS
7989 6
2556
8105 5
8680 9
2778
8828 5
9403 9
3008
9550 5
10125 9
3238
10273 5
10848 9
3468
10996 5
40
LC
tC
t
9
16
n (Nos) 28
150 ± 2 1100
+5 - 3
6
32 36
155 ± 2
40
19 60
1150
6660 5 7383 5
Rib
44 48
12
+5 -3
52 22
160 ± 2
58 9 64 72
180 ± 2 1200
+5 - 3
78 70
16
25 84 90
Figure 16: Shape, Dimensions and Dimensional Tolerances of Type-T Intermediate Pipe B – B Section View
Grout Holes (4 locations on circumference)
(Unit: mm) Nom. Dia Internal Dia. D
Eff. Length D1
1000
1000 6
1164
1100
1100 6
1274
1200
1200 6
1388
1350
1350 8
1551
1500
1500 8
1731
1650
1650 8
1901
1800
1800 10
2071
2000
2000 10
2301
2200
2200 10
2531
2400
2400 12
2749
2600
2600 12
2979
2800
2800 12
3209
3000
3000 12
3439
+3 - 2 +3 - 2 +3 - 2 +4 - 3 +4 - 3 +4 - 3 +4 - 3 +4 - 3 +4 - 3 +5 - 3 +5 - 3 +5 - 3 +5 - 3
D1
DC
DC+2t C)
3657 3
1191
3770 3
4002 3
1301
4115 3
4361 3
1421
4492 3
4873 6
1588
5027 5
5438 6
1768
5592 5
5972 6
1938
6126 5
6506 6
2108
6660 5
7229 6
2338
7383 5
7951 6
2568
8105 5
8636 9
2792
8828 5
9359 9
3022
9550 5
10081 9
3252
10273 5
10804 9
3482
10996 5
41
LT
1150
LC
+5 - 3
130 ± 2 1200
1250
+5 - 3
+5 - 3
150 ± 2
Figure 16: (Continued) (Unit: mm) “a” Details
“b” Details
Gasket for Intermediate Pipe
Lubricant inlet
Nom inal Dia
a
125
60
65
92.5
26
b
tC
t1
t2
1000 18 1100 1200
6
4.5 21
9
1350 1500
6
1650 140
65
75
102.5
30
24
6
1800 2000 9 2200 12 2400 2600 150
70
80
110
2800 3000
42
34
30
9
9
4. RUBBER RING 4.1
Classification As shown in Figure 17, rubber rings are categorized in accordance with Standard Pipe and Intermediate Pipe use. Table 17: Classification of Rubber Ring
Classification
Range of Nominal Diameter
For Standard Pipe
800 ~ 3000
For Intermediate Pipe
1000 ~ 3000
For Standard Pipe Embedded Steel Collar
Anchors Embedded Rubber Seal Cushion Ring
Rubber Gasket
For Intermediate Pipe
Gaskets for
Gasket for
Type-S
Jacking
Standard Pipe
Intermediate Pipe
Direction
Cushion Ring Standard Pipe
Intermediate Pipe
Lubricant Inlet Intermediate Jacks
Cushion Ring
Support Ring
43
Type-T Intermediate Pipe
Standard Pipe
Cushion Ring
4.2
Quality 4.2.1 Appearance Rubber ring shall be free of cuts, cracks, air bubbles, impurities or other elements that are detrimental to its functional use.
4.2.2 Physical Properties Physical properties of rubber ring shall be in accordance with JIS K 6353 (Rubber Goods for Water Works).
4.3
Shape, Dimensions and Dimensional Tolerances The shape, dimensions and dimensional tolerances of rubber ring shall be in accordance with Figure 18. Figure 18: Shape, Dimensions and Dimensional Tolerances of Rubber Ring
Shape, Dimensions and Dimensional Tolerances of Rubber Ring for Standard Pipe
(Unit: mm) Nom. Dia. 800 ~ 1200 1350 ~ 2200 2400 ~ 3000
B
50 2
60 2
H
H’
h
a
15 0.5
10
2
5
20 0.5
14
3
6
23.5 0.5
16.5
5
7
b
c
d
e
f
g
3
10
5
4
4 2
i
R
3 80
85 1 of
Ring Seat
5 5
L (%)
Rubber
4.5 2.5
Length
3.5
12
8
5
100 Circumf’e
44
Shape, Dimensions and Dimensional Tolerances of Rubber Ring for Intermediate Pipe
Nom. Dia.
B
H
h1
h2
a
b
R
Length L (%)
1000 ~ 1200
26 2
13 1
6
7
3
9
15
90 1 of Rubber
1350 ~ 2200
30 2
19
9
10
4
11
16
Ring Seat
2400 ~ 3000
34 2
22.5
11.5
11
4.5
12
18
Circumference
5. OTHERS Matters not contained in this Appendix shall be referred to in JSWAS A-2 Standard.
45
I-II
HJP
1. REGISTRATION
(1)
Applicant
Kinki Hume Pipe Cooperative
(2)
Joint performance
JA
(3)
Registration No.
JA2
(4)
Registration date
1 November, 1999
(5)
Officialization of standard
1 April, 1991
(6)
Standard designation
KHK S-1
2. CLASSIFICATION
The classification of pipes are as described in Table 11. Table 11: Pipe Designs
Type
Shape
Standard Pipe
Intermediate Pipe
S T
External
Compressive
Joint
Strength
Strength
Specification
Class 1
Designation of Type
50
JA 51
70
JA 71
Class 2
50
-
-
Class 1
50
JAT51
Class 2
50
JAT52
JA
Applicable Pipe Size (nominal)
800~3000
JA 52 JAS 1000~3000
3. SHAPE, DIMENSIONS AND DIMENSIONAL TOLERANCES OF PIPE
The shape, dimensions, and dimensional tolerances for Standard Pipe and Intermediate Jacking Pipe are as given in Figures 18~21.
46
Standard Pipe The shape, dimensions, and dimensional tolerances for Standard Pipe is as given in Figure 19.
Figure 19: Shape, Dimensions and Dimensional Tolerances of Standard Pipe (Unit: mm)
Steel Collar
Grout Socket
Grout Sockets
Steel Collar
Joint Details
Rubber Ring Groove Soil-Stop Ring Groove
Cushion Ring
(Unit: mm) N o m in a l
In te rn a l D ia .
D ia .
D
D 1
D1
800
800 4
932
900
900 6
1052
1000
1000 6
1172
1100
1100 6
1282
1200
1200 6
1402
1350
1350 8
1562
1500
1500 8
1742
1650
1650 8
1912
1800
1800 10
2082
2000
2000 10
2312
2200
2200 10
2542
2400
2400 12
2762
2600
2600 12
2992
2800
2800 12
3222
3000
3000 12
3452
+ + + + + + + + + + + + + + + -
3 2 3 2 3 2 3 2 3 2 4 3 4 3 4 3 4 3 4 3 4 3 5 2 3 3 5 3 5 3
D2
T h ic k n e s s
E ff. L e n g th
T
L
2928 3
942
80
3305 3
1062
90
3682 3
1182
100
4028 3
1292
105
4405 3
1412
115
4907 6
1577
125
5473 6
1757
140
6007 6
1927
150
6541 6
2097
160
7263 6
2327
175
7986 6
2557
190
8677 9
2779
205
9400 9
3009
220
10122 9
3239
235
10845 9
3469
250
47
+ + + + + + + + + + + + + + + -
4 2 6 3 6 3 6 3 6 3 8 4 8 4 8 4 10 5 10 5 10 5 12 6 12 6 12 6 12 6
2430
40
30
50
40
+ 10 - 5
Figure 19: (Continued) (Unit: mm) Dc
(D c + 2 T c )
800
951
3016 3
900
1071
3393 3
1191
3770 3
1100
1301
4115 3
1200
1421
4492 3
1588
5027 5
1768
5592 5
1938
6126 5
1800
2108
6660 5
2000
2338
7383 5
2200
2568
8105 5
2400
2792
8828 5
3022
9550 5
3252
10273 5
3482
10996 5
N o m in a l D ia
Lc 1
Lc 2
Lc
Tc
4 .5
1000
1350
120
130 ± 2
250
+ 5 - 2
1500 1650 6
2600 150
150 ± 2
300
2800
+ 5 - 2
9
3000
Notes: 10
1.
The effective length of standard pipe (L) may also be 1200 5 .
2.
The steel collar may be omitted for standard pipe. The effective lengths of the pipes may be: 2430 20 or
10
10
1200 20
3.
The difference of maximum and minimum measurements of effective length shall be within 3mm.
4.
For pipes 1000mm and larger, pre-embedded locking sockets (for pipe-pipe connection) may be installed.
5.
The positions and quantity of grout holes may be altered as necessary.
48
Intermediate Pipes The combined lengths of Type-S and Type-T Intermediate Pipes are as given in Table 12. The shape, dimensions, and dimensional tolerances are as given in Figures 20~21.
Table 12: Combination of Type-S and Type-T Intermediate Pipes (Unit: mm)
N o m in a l D ia .
E f f . L e n g th o f S E f f . L e n g th o f T C o m b in e d LS
LT
L e n g th
1000 150
1310
1100
1150
1200 1350
1315 155 1365
1500 1650 1200 1800 160
1370
2000 2200 2400 2600 180
1250
2800 3000
49
1440
Figure 20: Shape, Dimensions and Dimensional Tolerances of Type-S Intermediate Pipe
A – A Section View
Rib t x n
Concrete or mortar
Concrete or mortar
“a” Details
“b” Details
In-Situ mortar finish Gasket for Standard Pipe
(Unit: mm) Nominal Int. Dia. Dia. 1000
D 1000
Eff. Lgth. DS 1024
1100
1100
1124
1200
1200
1224
1350
1350
1374
1500
1500
1524
1650
1650
1674
1800 2000
1800 2000
1824 2024
2200
2200
2224
2400
2400
2424
2600
2600
2624
2800
2800
2824
3000
3000
3024
D1 +3 1173 - 2 +3 1283 - 2 +3 1403 - 2 +4 1563 - 3 +4 1743 - 3 +4 1913 - 3 +4 2083 - 3 +4 2313 - 3 +4 2543 - 3 +5 2763 - 3 +5 2993 - 3 +5 3223 - 3 +5 3453 - 3
D1
DC
DC+2t C)
3685 3
1182
3770 3
4031 3
1292
4115 3
4408 3
1406
4492 3
4910 6
1576
5027 5
5476 6
1756
5592 5
6010 6
1926
6126 5
6544 6 7267 6
2096 2326
7383 5
2556
8105 5
8680 9
2778
8828 5
9403 9
3008
9550 5
10125 9
3238 10273 5
10848 9
3468 10996 5
LC
tC
t
9
16
n (Nos) 28
150 ± 2 1100
+5 - 3
6
32 36
155 ± 2
19
40
60
1150
6660 5
7989 6
50
LS
Rib
44 12
+5 -3
48 52
160 ± 2
22 58 9 64 72
180 ± 2 1200
+5 - 3
78 70
16
25 84 90
Figure 21: Shape, Dimensions and Dimensional Tolerances of Type-T Intermediate Pipe B-B Section View
Grout Holes (4 locations on circumference)
(Unit: mm) Nominal
Int. Dia.
Dia.
D
Eff. Legnth D1
1000
1000 6
1164
1100
1100 6
1274
1200
1200 6
1388
1350
1350 8
1551
1500
1500 8
1731
1650
1650 8
1901
1800
1800 10
2071
2000
2000 10
2301
2200
2200 10
2531
2400
2400 12
2749
2600
2600 12
2979
2800
2800 12
3209
3000
3000 12
3439
+3 - 2 +3 - 2 +3 - 2 +4 - 3 +4 - 3 +4 - 3 +4 - 3 +4 - 3 +4 - 3 +5 - 3 +5 - 3 +5 - 3 +5 - 3
D1
DC
DC+2t C)
3657 3
1191
3770 3
4002 3
1301
4115 3
4361 3
1421
4492 3
4873 6
1588
5027 5
5438 6
1768
5592 5
5972 6
1938
6126 5
6506 6
2108
6660 5
7229 6
2338
7383 5
7951 6
2568
8105 5
8636 9
2792
8828 5
9359 9
3022
9550 5
10081 9
3252
10273 5
10804 9
3482
10996 5
51
LT
1150
LC
+5 - 3
130 ± 2 1200
1250
+5 - 3
+5 - 3
150 ± 2
Figure 21: (Continued) “a” Details
“b” Details
Gasket for Intermediate Pipe
Lubricant inlet
(Unit: mm) Nom inal Dia
a
125
60
65
92.5
26
b
tC
t1
t2
1000 18 1100 1200
6
4.5 9
21
1350 1500
6
1650 140
65
75
102.5
30
24
6
1800 2000 9 2200 12 2400 2600 150
70
80
110
2800 3000
52
34
30
9
9
RUBBER RING Classification As shown in Figure 22 and 23, rubber rings are categorized in accordance with Standard Pipe and Intermediate Pipe use.
Quality Appearance Rubber ring shall be free of cuts, cracks, air bubbles, impurities or other elements that are detrimental to its functional use.
Physical Properties Physical properties of rubber ring shall be in accordance with JIS K 6353 (Rubber Goods for Water Works).
Shape, Dimensions and Dimensional Tolerances The shape, dimensions and dimensional tolerances of rubber ring shall be in accordance with Figures 22 and 23. Figure 22: Shape, Dimensions and Dimensional Tolerances of Rubber Ring for Standard Pipe
(Unit: mm) Nom. Dia. 800 ~ 1200 1350 ~ 2200 2400 ~ 3000
B
50 2
60 2
H
H’
h
a
14 0.5
9
2
5
19.5 0.5
13.5
3
6
22.5 0.5
15.5
5
7
b
c
d
e
f
3
10
5
4 2 4.5
g
i
4
3
R
80 4
5
5
5
Length
L (%) 85 1 of Rubber Ring Seat
2.5
5
3.5
12
8
100 Circumf’e
53
Figure 23: Shape, Dimensions and Dimensional Tolerances of Rubber Ring for Intermediate Pipe
Nom. Dia.
B
1000 ~ 1200
26 1
1350 ~ 2200
30 1
H
h1
h2
a
b
R
6
7
3
9
15
Length L (%)
+ 0.5
13 -
0
90 1 of Rubber
+ 0.5
19
9 -
10
4
11
16
Ring Seat
0
Circumference 2400 ~ 3000
34 1
+ 0.5
22.5
11.5 -
11
4.5
12
18
0
SOIL-STOP RING Appearance Rubber ring shall be free of cuts, cracks, air bubbles, impurities or other elements that are detrimental to its functional use.
Physical Properties Physical properties of rubber ring shall be in accordance with JIS K 6353 (Rubber Goods for Water Works); Class IV-50.
Shape, Dimensions and Dimensional Tolerances The shape, dimensions and dimensional tolerances of rubber ring shall be in accordance with Figure 24.
54
Figure 24: Shape, Dimensions and Dimensional Tolerances of Soil-Stop Ring
Nom. Dia.
B
800 ~ 1200 1350 ~ 2200 2400 ~ 3000
42 2
H
h1
h2
h3
11.5 0.5
6
3
3
12.5 0.5
7
13.5 0.5
8
a
b
c
d
e
f
90 1 of Rubber
3 5.5
3.5
3.5
Length L (%)
8
20
11
5
Ring Seat
3.5 4
6
55
4
Circumference
II. JB JOINT SPECIFICATION
II-I
W-JOINT PIPE
1. REGISTRATION
(1)
Applicant
Japan W-Joint Pipe Association
(2)
Joint performance
JB
(3)
Registration No.
JB1
(4)
Registration date
1 November, 1999
(5)
Officialization of standard
1 April, 1995
(6)
Standard designation
JWJPAS J-2
2. CLASSIFICATION
The classification of pipes are as described in Table 13. Table 13: Pipe Designs
Type
Shape
Standard Pipe
Intermediate Pipe
S T
External
Compressive
Joint
Strength
Strength
Specification
Class 1
Designation of Type
50
JB 51
70
JB 71
Class 2
50
-
-
Class 1
50
JBT51
Class 2
50
JBT52
JB
Applicable Pipe Size (nominal)
800~3000
JB 52 JBS 1000~3000
3. SHAPE, DIMENSIONS, AND DIMENSIONAL TOLERANCES OF PIPE
The shape, dimensions, and dimensional tolerances for Standard Pipe and Intermediate Jacking Pipe are as given in Figures 25~27.
56
3.1
Standard Pipe The shape, dimensions, and dimensional tolerances for Standard Pipe is as given in Figure 25.
Figure 25: Shape, Dimensions and Dimensional Tolerances of Standard Pipe (Unit: mm) Lubricant inlet
Lubricant inlet
Lubricant and water-stop material inlet
Lubricant and water-stop
Steel Collar
material inlet
Joint Details
“A” Details
Gasket for Standard Pipe
Steel Collar
Anchor
Embedded Rubber Seal Cushion Ring
(Unit : mm) Nom inal
Int. Dia.
Dia.
D
Thickness Eff. Length D1
D 2
800
800 4
942 2
2922
900
900 6
1062 2
3299
1000
1000 6
1182 2
3676
1100
1100 6
1292 2
4021
1200
1200 6
1412 2
4398
1350
1350 8
1576 3
4901
1500
1500 8
1756 3
5466
1650
1650 8
1926 3
6000
1800
1800 10
2096 3
6535
2000
2000 10
2326 3
7257
2200
2200 10
2556 3
7980
2400
2400 12
2778 3
8671
2600
2600 12
3008 3
9393
2800
2800 12
3238 3
10116
3000
3000 12
3468 3
10839
+ + + + + + + + + + + + + + + -
T 6 3 6 3 6 3 6 3 6 3 6 3 6 3 6 3 6 3 6 3 6 3 9 3 9 3 9 3 9 3
80 90 100 105 115 125 140 150 160 175 190 205 220 235 250
57
L + + + + + + + + + + + + + + + -
4 2 6 3 6 3 6 3 6 3 8 4 8 4 8 4 10 5 10 5 10 5 12 6 12 6 12 6 12 6
2430
+ 10 - 5
a
b,d
c
26
6
9
30
8
12
34
9
16
150
+4 - 0
Figure 25: (Continued) (Unit: mm) N o m in a l D ia
Lc
1
Lc
Lc
2
Tc
Dc
D 0 + + + + + -
3 2 3 2 3 2 3 2 3 2
800
951
3016
900
1071
3393
1191
3770
1100
1301
4115
1200
1421
4492
1350
1588
5027 ± 3
1500
1768
5592 ± 3
1938
6126 ± 3
2108
6660 ± 3
2338
7383 ± 3
2568
8105 ± 3
2792
8828 ± 3
3022
9550 ± 3
2800
3252
10273 ± 3
3000
3482
10996 ± 3
1000
1650
4 .5
300 ± 2
150
6 1800 2000 150 2200
+ 3 - 2
2400 2600 9
Notes: 1. π・D2 is the circumference of the base of the groove for rubber gasket. This is the same as
D2 = D1 - 2b 2. π・D0 is the external circumference of the collar. This is the same as D0 = Dc + 2Tc 10
3. The effective length of standard pipe (L) may also be 1200 5
4. The steel collar may be omitted for standard pipe. The effective lengths of the pipes may 10 be: 2430 10 20 or 1200 20
5. The difference of maximum and minimum measurements of effective length shall be within
3mm. 6. The positions and quantity of grout holes may be altered as necessary.
58
3.2
Intermediate Pipes The combined lengths of Type-S and Type-T Intermediate Pipes are as given in Table 14. The shape, dimensions, and dimensional tolerances are as given in Figures 26~27.
Table 14: Combination of Type-S and Type-T Intermediate Pipes (Unit: mm)
Nom inal Dia.
Eff.Length of S Eff.Length of T Com bined LS LT Length
1000 1100 1200
1150
1330
170
1350 1380 1500 1650 1200 1800 1385
175 2000 2200 2400 2600 180
1250
2800 3000
59
1440
Figure 26: Shape, Dimensions and Dimensional Tolerances of Type-S Intermediate Pipe
A - A Section View
Rib t x n Concrete or mortar
Concrete or mortar
(Unit: mm) Nominal
Int. Dia.
Dia.
D
1000
1000
1024
1100
1100
1124
1200
1200
1224
1350
1350
1374
1500
1500
1524
1650
1650
1674
1800
1800
1824
2000
2000
2024
2200
2200
2224
2400
2400
2424
2600
2600
2624
2800
2800
2824
3000
3000
3024
D 1
DC
1170 2
3676 3
1182
3770
1280 2
4021 3
1292
4115
1400 2
4398 3
1406
4492
1560 3
4901
1576
5027 3
1740 3
5466
1756
5592 3
1910 3
6000
1926
6126 3
2080 3
6535
2096
6660 3
2310 3
7257
2326
7383 3
2540 3
7980
2556
8105 3
2760 3
8671
2778
8828 3
2990 3
9393
3008
9550 3
3220 3
10116
3238
10273 3
3450 3
10839
3468
10996 3
D1
DS + + + + + + + + + + + + + -
3 0 3 0 3 0 4 0 4 0 4 0 4 0 4 0 4 0 5 0 5 0 5 0 5 0
60
+ + + + + + + + + + -
6 3 6 3 6 3 6 3 6 3 6 3 9 3 9 3 9 3 9 3
D 0 + + + -
3 2 3 2 3 2
Figure 26: (Continued)
“a” Details
“b” Details
Gasket for Standard Pipe In-Situ mortar finish
(Unit: mm) Nominal
Eff. Length
Dia.
LS
Rib LC
a1
a2
1
tC
t
9
16
n (Nos.)
1000
28
1100 1200
1100
+5 - 3
29
26
6
170 ± 2
32 36
19
1350
40
1500
44
1650 1150 1800
+5 -3
12 33
48
30 40
60
52
175 ± 2
22 58
2000 9 2200
64
2400
72
2600 180 ± 2 2800
1200
+5 - 3
78 37
34
16
25 84 90
3000
Note: π・D0 is the external circumference of the collar. This is the same as D0 = Dc + 2Tc
61
Figure 27: Shape, Dimensions and Dimensional Tolerances of Type-T Intermediate Pipe
B-B Section View
Grout Holes (4 locations on circumference)
(Unit : mm) Nominal
Inter. Dia.
Dia.
D
Eff. Length D1
D1
DC
D0 +3 - 2 +3 - 2 +3 - 2
1000
1000 6
1164 2
3657 3
1191
3770
1100
1100 6
1274 2
4002 3
1301
4115
1200
1200 6
1388 2
4361 3
1421
4492
1350
1350 8
1551 3
4873
1588
5027 3
1500
1500 8
1731 3
5438
1768
5592 3
1650
1650 8
1901 3
5972
1938
6126 3
1800
1800 10
2071 3
6506
2108
6660 3
2000
2000 10
2301 3
7229
2338
7383 3
2200
2200 10
2531 3
7951
2400
2400 12
2749 3
8636
2600
2600 12
2979 3
9359
2800
2800 12
3209 3
10081
3000
3000 12
3439 3
10804
Notes:
+6 - 3 +6 - 3 +6 - 3 +6 - 3 +6 - 3 +6 - 3 +9 - 3 +9 - 3 +9 - 3 +9 - 3
2568
8105 3
2792
8828 3
3022
9550 3
3252 10273 3
LT
1150
1200
LC
+5 - 3
150 2
+5 - 3
150
1250
+5 - 3
3482 10996 3
1. π・D0 is the external circumference of the collar. This is the same as D0 = Dc + 2Tc 2. π・D1 is the circumference of the base of the groove for rubber gasket. 3. The difference of maximum and minimum measurements of effective length shall be within 3mm. 4. The positions and quantity of grout holes may be altered as necessary.
62
+3 - 2
Figure 27: (Continued)
(Unit: mm) “a” Details
“b” Details
Gaskets for
12
Intermediate Pipe Lubricant inlet
N o m in a l D ia
a
b
tC
t1
t2
1000 18 1100
125
60
65
9 2 .5
1200
6
4 .5
26
9
21
1350 1500
6
1650 140
65
75
1 0 2 .5
30
2 4 .5
6
1800 2000 9 2200 12 2400 2600 150
70
80
110
34
3 0 .5
9
9
2800 3000
Notes:
1. π・D0 is the external circumference of the collar. This is the same as D0 = Dc + 2Tc 2. π・D1 is the circumference of the base of the groove for rubber gasket. 3. The difference of maximum and minimum measurements of effective length shall be within 3mm. 4. The positions and quantity of grout holes may be altered as necessary.
63
4
RUBBER RING 4.1
Classification As shown in Figure 28, rubber rings are categorized in accordance with Standard Pipe and Type-S Intermediate Pipe, and Type-T Intermediate Pipe use. In addition, rubber rings for Standard Pipe and Type-S Intermediate Pipe are sub-categorized for fixing positions; namely, for connection, and for jointing. Figure 28: Classification of Rubber Rings
Classification
Range of Nominal
Code
Diameter
For Standard Pipe
Connection
EWSG
For Type-S Intermediate Pipe
Jointing
EWTG
For Type-T Intermediate Pipe
EWMG
800 ~ 3000 1000 ~ 3000
For Standard Pipe
Rubber Ring for Jointing
Anchor
Rubber Ring for Connection
Embedded Rubber Seal
For Intermediate Pipes Rubber Ring for Connection
Standard Pipe
4.2
Rubber Ring for Jointing Rubber Rings for Intermediate Pipe
Cushion Rings
Standard Pipe
Quality 4.2.1
Appearance Rubber ring shall be free of cuts, cracks, air bubbles, impurities or other elements that are detrimental to its functional use.
64
4.2.2
Physical Properties Physical properties of rubber ring shall be in accordance with JIS K 6353 (Rubber Goods for Water Works).
4.3
Shape, Dimensions and Dimensional Tolerances The shape, dimensions and dimensional tolerances of rubber ring shall be in accordance with Figure 29. Figure 29: Shape, Dimensions and Dimensional Tolerances of Rubber Ring for Standard Pipe and Type-S Intermediate Pipe (Unit: mm) Rubber Ring for Connection
Rubber Ring for Jointing
(Unit: mm) Rubber Ring for Connection
Nominal Diameter
B
800 ~ 1200
27 1
1350 ~ 2200
31 1
H
b1
b2
b3
H1
h2
29
6
8
8
7
Length L (%)
+ 0.5
14 -
0
85 1 of Rubber
+ 0.5
33
19 -
6
8
11
9
Ring Seat
0
Circumference 2400 ~ 3000
35 1
+ 0.5
22
37 -
6
0
65
8
12
10
Figure 29: (Continued) (Unit: mm) Rubber Ring for Jointing Nom. Dia. B 800 ~ 1200
26 1
H
30 1
h1
h2
h3
a
b
c
d
e
j
k
R
10
5
5
3
9
9
2
4
3
5
50
0
85 1 of
+ 0.5 20
15 -
7
5
4
11
12
2
4.5
3
7
60
0
34 1
23
Circumf’e 16
-
Rubber Ring Seat
+ 0.5 2400 ~ 3000
L (%)
+ 0.5 15 -
1350 ~ 2200
Length
8
6
4.5
12
13
2.5
5
3.5
9
70
0
for Intermediate Pipes
(Unit: mm) Nom. Dia.
B
1000 ~ 1200
26 1
1350 ~ 2200
30 1
H
h1
h2
a
b
7
3
9
Length L (%)
+ 0.5
13
6 -
15
0
90 1 of Rubber
+ 0.5
9
19 -
10
4
11
16
Ring Seat
0
Circumference 2400 ~ 3000
5
34 1
+ 0.5
22.5
11.5 -
11
4.5
12
18
0
OTHERS Matters not contained in this Appendix shall be referred to in JWJPAS J-2 Standard.
66
III. JC JOINT SPECIFICATION
II-I
NS JACKING PIPE
1. REGISTRATION (1)
Applicant
Japan Hume Pipe Association
(2)
Joint performance
JC
(3)
Registration No.
JC1
(4)
Registration date
1 November, 1999
(5)
Officialization of standard
19 July, 1995
(6)
Standard designation
JHPAS - 25
2. CLASSIFICATION The classification of pipes are as described in Table 15. Table 15: Pipe Designs
Type
Shape
Standard Pipe
S
Intermediate Pipe
T
External
Compressive
Joint
Strength
Strength
Specification
Class 1
Designation of Type
50
JC 51
70
JC 71
Class 2
50
-
-
Class 1
50
JCT51
Class 2
50
JCT52
JC
Applicable Pipe Size (nominal)
800~3000
JC 52 JCS 1000~3000
3. SHAPE, DIMENSIONS AND DIMENSIONAL TOLERANCES OF PIPE
The shape, dimensions, and dimensional tolerances for Standard Pipe and Intermediate Jacking Pipe are as given in Figures 30~32.
67
3.1
Standard Pipe The shape, dimensions, and dimensional tolerances for Standard Pipe is as given in Figure 30.
Figure 30: Shape, Dimensions and Dimensional Tolerances of Standard Pipe (Unit: mm) Grout Sockets
Joint Details
No. 1 Rubber Ring
Steel Collar Embedded Rubber Seal
No. 2 Rubber Ring
t
Cushion Ring
Steel Collar Details
Nominal Diameters 800 ~ 1200
(Unit: mm)
68
Figure 30: (Continued) (Unit: mm) Nominal Diameters 1350 ~ 2200
Nominal Diameters 2400 ~ 3000
(Unit: mm) Nominal
Int. Dia.
Dia.
D
Thickness Eff. Length D1
D2
D2
800
800 4
930
938
900
900 6
1050
1058
1000
1000 6
1170
1178
1100
1100 6
1280
1288
1200
1200 6
1400
1408
1350
1350 8
1560
1568
1500
1500 8
1740
1748
1650
1650 8
1910
1918
1800
1800 10
2080
2088
2000
2000 10
2310
2318
2200
2200 10
2540
2548
2400
2400 12
2760
2768
2600
2600 12
2990
2998
2800
2800 12
3220
3228
3000
3000 12
3450
3458
+3 - 2 +3 - 2 +3 - 2 +3 - 2 +3 - 2 +4 - 3 +4 - 3 +4 - 3 +4 - 3 +4 - 3 +4 - 3 +5 - 3 +5 - 3 +5 - 3 +5 - 3
h
T
2947 3
80
3324 3
90
3701 3
11
100
4046 3
105
4423 3
115
4926 6
125
5492 6
140
6026 6
150
6560 6
16 160
7282 6
175
8005 6
190
8696 9
205
9418 9 10141 9 10864 9
69
220 21 235 250
L +4 - 2 +6 - 3 +6 - 3 +6 - 3 +6 - 3 +8 - 4 +8 - 4 +8 - 4 + 10 - 5 + 10 - 5 + 10 - 5 + 12 - 6 + 12 - 6 + 12 - 6 + 12 - 6
2430
+ 10 - 5
172 2
Figure 30: (Continued)
(Unit: mm) N o m in a l D ia
Lc
1
Lc
Lc
2
Tc
Dc
D c+ 2 T c)
800
951
3016 ± 3
900
1071
3393 ± 3
1191
3770 ± 3
1100
1301
4115 ± 3
1200
1421
4492 ± 3
1350
1588
5027 ± 5
1768
5592 ± 5
1938
6126 ± 5
1800
2108
6660 ± 5
2000
2338
7383 ± 5
2200
2568
8105 ± 5
2400
2792
8828 ± 5
3022
9550 ± 5
2800
3252
10273 ± 5
3000
3482
10996 ± 5
1000
4 .5
1500 1650
150
320
+ 5 - 2
6
2600 9
Note : 10
1.
The effective length of standard pipe may also be
2.
The steel collar may be omitted for standard pipe. The effective lengths of the pipes may be: 2430 20 or
1200 5
10
10
1200 20
3.
The difference of maximum and minimum measurements of effective length shall be within 3mm.
4.
For pipes 1000mm and larger, pre-embedded locking sockets (for pipe-pipe connection) may be installed.
5.
The positions and quantity of grout holes may be altered as necessary.
70
3.2
Intermediate Pipes The combined lengths of Type-S and Type-T Intermediate Pipes are as given in Table 16. The shape, dimensions, and dimensional tolerances are as given in Figures 31~32. Table 16: Combination of Type-S and Type-T Intermediate Pipes (Unit: mm) N o m in a l D ia .
E ff. L e n g th o f S LS
E ff. L e n g th o f T LT
C o m b in e d L e n g th
1000 1350
190 1100
1150 1355
1200 1350 1500 1650
195 1200
1405
1250
1480
1800 2000 2200 2400 2600 220 2800 3000
Figure 31: Shape, Dimensions and Dimensional Tolerances of Type-S Intermediate Pipe
A – A Section View
Rib t2 x n
Concrete or mortar
Concrete or mortar
71
Figure 31: (Continued) “a” Details
“b” Details
(Unit: mm)
In-Situ mortar finish
(Unit: mm) Nominal Int. Dia. Dia. 1000
D 1000
DS 1024
1100
1100
1124
1200
1200
1224
1350
1350
1374
1500
1500
1524
1650
1650
1674
1800
1800
Rib
Eff. Lgth.
1824
2000
2000
2024
2200
2200
2224
2400
2400
2424
2600
2600
2624
2800
2800
2824
3000
3000
3024
D3 +3 1174 - 2 +3 1284 - 2 +3 1404 - 2 +4 1564 - 3 +4 1744 - 3 +4 1914 - 3 +4 2084 - 3 +4 2314 - 3 +4 2544 - 3 +5 2764 - 3 +5 2994 - 3 +5 3224 - 3 +5 3454 - 3
D3
DC1
DC1+2t 1)
3688 3
1182
3770 3
4034 3
1292
4115 3
4411 3
1406
4492 3
4913 6
1576
5027 5
5479 6
1756
5592 5
6013 6
1926
6126 5
6547 6
2096
6660 5
LS
LC3
2
t1
t2
174
9
16
n (Nos.)
28 190 ± 2 1100
+5 - 3
32 36 176
19
40 44
195 ± 2 1150
12
+5 -3
48 52
173
22
7270 6
2326
7383 5
7992 6
2556
8105 5
64
8683 9
2778
8828 5
72
9406 9
3008
9550 5
10128 9
3238 10273 5
10851 9
3468 10996 5
72
58
200 ± 2 1200
+5 - 3
78 175 16
25 84 90
Figure 32: Shape, Dimensions and Dimensional Tolerances of Type-T Intermediate Pipe
B-B Section View
Grout Holes (4 locations on circumference)
(Unit: mm) Nominal
Int. Dia.
Dia.
D
Eff. Length D4
1000
1000 6
1164
1100
1100 6
1274
1200
1200 6
1388
1350
1350 8
1551
1500
1500 8
1731
1650
1650 8
1901
1800
1800 10
2071
2000
2000 10
2301
2200
2200 10
2531
2400
2400 12
2749
2600
2600 12
2979
2800
2800 12
3209
3000
3000 12
3439
+3 - 2 +3 - 2 +3 - 2 +4 - 3 +4 - 3 +4 - 3 +4 - 3 +4 - 3 +4 - 3 +5 - 3 +5 - 3 +5 - 3 +5 - 3
D4
DC
DC+2TC)
3657 3
1191
3770 3
4002 3
1301
4115 3
4361 3
1421
4492 3
4873
1588
5027 5
5438
1768
5592 5
5972
1938
6126 5
6506
2108
6660 5
7229
2338
7383 5
7951
2568
8105 5
8636
2792
8828 5
9359
3022
9550 5
10081
3252 10273 5
10804
3482 10996 5
73
LT
1150
1200
LC2
+5 - 3
+5 - 3
170 2
1250
+5 - 3
Figure 32: (Continued) “a” Details
“b” Details
(Unit: mm)
Gasket for Intermediate Pipe
Lubricant inlet
(Unit: mm) N o m in a l D ia
3
4
a
b
T
C
t3
t4
1000 18 1100
125
60
65
9 2 .5
1200
6
4 .5
26 21
9
1350 1500
6
1650 140
65
75
1 0 2 .5
30
24
6
1800 2000 9 2200 12 2400 2600 150
70
80
34
110
2800 3000
74
30
9
9
4
RUBBER RING 4.1
Classification As shown in Figure 33, rubber rings are categorized in accordance with Standard Pipe and Intermediate Pipe use. Figure 33: Classification of Rubber Rings
Range of Nominal
Classification For Standard Pipe
Diameter
No. 1 Rubber Ring No. 2 Rubber Ring
For Intermediate Pipes
800 ~ 3000 1000 ~ 3000
For Standard Pipe
Steel Collar
No. 1 Rubber Ring
Embedded Rubber Seal
No. 2 Rubber Ring
Cushion Ring
For Intermediate Pipes T-Type Intermediate Pipe Rubber Rings for Intermediate Pipe Standard Pipe
S-Type Intermediate Pipe
No. 1 Rubber Ring No. 2 Rubber Ring Standard Pipe
Cushion Rings
4.2
Quality 4.2.1 Appearance Rubber ring shall be free of cuts, cracks, air bubbles, impurities or other elements that are detrimental to its functional use.
4.2.2 Physical Properties Physical properties of rubber ring shall be in accordance with JIS K 6353 (Rubber Goods for Water Works). 75
4.3
Shape, Dimensions and Dimensional Tolerances The shape, dimensions and dimensional tolerances of rubber ring shall be in accordance with Figure 34. Figure 34: Shape, Dimensions and Dimensional Tolerances of Rubber Ring for Standard Pipe (Unit: mm) No. 1 Rubber Ring
B
Nom. Dia.
H
800~1200 1350~2200
34 ±1.0
b
c
d
e
Length L (%)
12
± 0.5
5
4
1
3
4
102 ± 1 of Rubber
18
± 0.5
8
6
1
4
7
Ring Seat
9.5
7.5
3
4.5
8.5
Circumference
21.5 ± 0.5
2400~3000
a
No. 2 Rubber Ring
Nom. Dia.
B
800 ~ 1200
H
a
b
c
14.5 ± 0.5
4
5
0
Length
f
g
h
i
j
k
l
R1
R2
R3
R4
7.5 8.5
2
2
9
11
6
26
4.5
4
8
2
5
3.5
10.5 12
3
3
8
12
7.5
26
4
5
7
2.5
5
4
4
4
8
12
6.5
25
4
6
7
3
5.5
5
d
e
L (%) 102 ± 1
1350 ~ 2200 34 ± 1.0
20
± 0.5 5.8
8
0
2400 ~ 3000
23
± 0.5
9
2
(*) 7
13
14
(*) : of Rubber Ring Seat Circumference
76
Shape, Dimensions and Dimensional Tolerances of Rubber Ring for Intermediate Pipes
5
Nom. Dia.
B
H
h1
h2
a
b
R
1000 ~ 1200
26 ± 1.0
13 ±0.5
6
7
3
9
15
1350 ~ 2200
30 ± 1.0
19 ±0.5
9
10
4
11
16
2400 ~ 3000
34 ± 1.0 22.5 ±0.5 11.5
11
4.5
12
18
Length L (%) 90 ± 1 of Rubber Ring Seat Circumference
OTHERS
Matters not contained in this Appendix shall be referred to in JHPAS – 25 Standard.
77
III-II. W-JOINT SPECIFICATION
II-I
W-JOINT PIPE
1. REGISTRATION
(1)
Applicant
Japan W-Joint Pipe Association
(2)
Joint performance
JC
(3)
Registration No.
JC2
(4)
Registration date
1 November, 1999
(5)
Officialization of standard
1 April, 1996
(6)
Standard designation
JWJPAS J-2N
2. CLASSIFICATION
The classification of pipes are as described in Table 17. Table 17: Pipe Designs
Type
Shape
Standard Pipe
Intermediate Pipes
S T
External
Compressive
Joint
Strength
Strength
Specification
Class 1
Designation of Type
50
JC 51
70
JC 71
Class 2
50
-
-
Class 1
50
JCT51
Class 2
50
JCT52
JC
Applicable Pipe Size (nominal)
800~3000
JC 52 JCS 1000~3000
3. SHAPE, DIMENSIONS AND DIMENSIONAL TOLERANCES OF PIPE
The shape, dimensions, and dimensional tolerances for Standard Pipe and Intermediate Jacking Pipe are as given in Figures 35~37.
78
3.1
Standard Pipe The shape, dimensions, and dimensional tolerances for Standard Pipe are as given in Figure 35.
Figure 35: Shape, Dimensions and Dimensional Tolerances of Standard Pipe (Unit: mm)
Lubricant inlets
Lubricant inlet
Lubricant and water-stop material inlet
Lubricant and water-stop material inlet
Nominal Diameter: 800 ~ 2200
Joint Details
Steel Collar
Embedded Rubber Seal
Rubber Rings for Std. Pipe
t
Cushion Ring
D2
Anchor
“a” Details
79
Figure 35: (Continued) (Unit: mm)
Nominal Diameter: 2400 ~ 3000
Joint Details
“a” Details
Rubber Rings for Std. Pipe
Steel Collar
Anchor t
Embedded Rubber Seal
D2
Cushion Ring
(Unit: mm) Nominal
Int. Dia.
Dia.
D
D1
D2
800
800 4
942 2
2922
900
900 6
1062 2
3299
1000
1000 6
1182 2
3676
1100
1100 6
1292 2
4021
1200
1200 6
1412 2
4398
1350
1350 8
1576 3
4901
1500
1500 8
1756 3
5466
1650
1650 8
1926 3
6000
1800
1800 10
2096 3
6535
2000
2000 10
2326 3
7257
2200
2200 10
2556 3
7980
2400
2400 12
2778 3
8671
2600
2600 12
3008 3
9393
2800
2800 12
3238 3
10116
3000
3000 12
3468 3
10839
+6 - 3 +6 - 3 +6 - 3 +6 - 3 +6 - 3 +6 - 3 +6 - 3 +6 - 3 +6 - 3 +6 - 3 +6 - 3 +9 - 3 +9 - 3 +9 - 3 +9 - 3
Thickness
Eff. Length
T
L
80 90 100 105 115 125 140 150 160 175 190 205 220 235 250
+4 - 2 +6 - 3 +6 - 3 +6 - 3 +6 - 3 +8 - 4 +8 - 4 +8 - 4 + 10 - 5 + 10 - 5 + 10 - 5 + 12 - 6 + 12 - 6 + 12 - 6 + 12 - 6
a
b,d
c
26
6
9
1
180
2430
80
+ 10 - 5
30
8
12
34
9
16
+4 - 0
2
3
4
5
6
50
60 110 130
35
55 62.5 120 140
190
+4 - 0
40
60
70
-
-
Figure 35: (Continued) (Unit: mm)
N o m in a l D ia
Lc
1
Lc
Lc
2
Tc
Dc
D 0 + + + + + -
3 2 3 2 3 2 3 2 3 2
800
951
3016
900
1071
3393
1191
3770
1100
1301
4115
1200
1421
4492
1588
5027 ± 3
1768
5592 ± 3
1938
6126 ± 3
2108
6660 ± 3
2000
2338
7383 ± 3
2200
2568
8105 ± 3
2400
2792
8828 ± 3
3022
9550 ± 3
3252
10273 ± 3
3482
10996 ± 3
1000
1350
150
4 .5
330 ± 2
1500 1650 180 1800
2600 150 2800
190
+ 3 - 2
+ 3 - 2
6 .0
340 ± 2
9 .0
3000
Notes:
1. π・D2 is the circumference of the base of the groove for rubber gasket. This is the same as D2 = D1 - 2b 2. π・D0 is the external circumference of the collar. This is the same as D0 = Dc + 2Tc 10
3.
The effective length of standard pipe (L) may also be
4.
The steel collar may be omitted for standard pipe. The effective lengths of the pipes may be: 2430 20 or
1200 5
10
10
1200 20
5.
The difference of maximum and minimum measurements of effective length shall be within 3mm.
6.
The positions and quantity of grout holes may be altered as necessary.
81
3.2
Intermediate Pipes The combined lengths of Type-S and Type-T Intermediate Pipes are as given in Table 18. The shape, dimensions, and dimensional tolerances are as given in Figures 36~37. Table 18: Combination of Type-S and Type-T Intermediate Pipes (Unit: mm) N o m in a l D ia .
E ff. L e n g th o f S LS
E ff. L e n g th o f T LT
C o m b in e d L e n g th
1150
1360
1000 1100 1200
200
1350 1410 1500 1650 1200 1800 205
1415
2000 2200 2400 2600 220
1250
1480
2800 3000
Figure 36: Shape, Dimensions and Dimensional Tolerances of Type-S Intermediate Pipe A – A Section View
Rib t x n Concrete or mortar
Concrete or mortar
“b” Details
“a” Details
Gasket for Standard Pipe In-Situ mortar finish
82
Figure 36: (Continued) (Unit: mm) N om inal
Int. D ia.
D ia.
D
DS
1000
1000
1024
1100
1100
1124
1200
1200
1224
1350
1350
1374
1500
1500
1524
1650
1650
1674
1800
1800
1824
2000
2000
2024
2200
2200
2224
2400
2400
2424
2600
2600
2624
2800
2800
2824
3000
3000
3024
D 1
DC
1170 2
3676 3
1182
3770
1280 2
4021 3
1292
4115
1400 2
4398 3
1406
4492
1560 3
4901
1576
5027 3
1740 3
5466
1756
5592 3
1910 3
6000
1926
6126 3
2080 3
6535
2096
6660 3
2310 3
7257
2326
7383 3
2540 3
7980
2556
8105 3
2760 3
8671
2778
8828 3
2990 3
9393
3008
9550 3
3220 3
10116
3238
10273 3
3450 3
10839
3468
10996 3
D1 + + + + + + + + + + + + + -
3 0 3 0 3 0 4 0 4 0 4 0 4 0 4 0 4 0 5 0 5 0 5 0 5 0
+ + + + + + + + + + -
6 3 6 3 6 3 6 3 6 3 6 3 9 3 9 3 9 3 9 3
D 0 + + + -
3 2 3 2 3 2
(Unit: mm) Nominal
Eff. Length
Dia.
LS
Rib LC
a1
a2
1
tC
t
9
16
1000
28
1100 1200
n (Nos.)
1100
+5 - 3
29
26
55
57.5
6
200 ± 2
32 36
1350
40
1500
30
1650 1150 1800
+5 -3
44 12
33
30
60
22
48
60 52
205 ± 2 2000
58 9
2200
64
2400
72
2600 220 ± 2 2800
1200
+5 - 3
78 37
34
35
65
67.5
16
84
3000
Note:
25
90
π・D0 is the external circumference of the collar. This is the same as D0 = Dc + 2Tc
83
Figure 37: Shape, Dimensions and Dimensional Tolerances of Type-T Intermediate Pipe B-B Section View
Grout Holes (4 locations on circumference)
(Unit: mm) Nominal
Int. Dia.
Dia.
D
Eff. Length D1
D1
DC
D0 +3 - 2 +3 - 2 +3 - 2
1000
1000 6
1164 2
3657 3
1191
3770
1100
1100 6
1274 2
4002 3
1301
4115
1200
1200 6
1388 2
4361 3
1421
4492
1350
1350 8
1551 3
4873
1588
5027 3
1500
1500 8
1731 3
5438
1768
5592 3
1650
1650 8
1901 3
5972
1938
6126 3
1800
1800 10
2071 3
6506
2000
2000 10
2301 3
7229
2200
2200 10
2531 3
7951
2400
2400 12
2749 3
8636
2600
2600 12
2979 3
9359
2800
2800 12
3209 3
10081
3000
3000 12
3439 3
10804
+6 - 3 +6 - 3 +6 - 3 +6 - 3 +6 - 3 +6 - 3 +9 - 3 +9 - 3 +9 - 3 +9 - 3
84
2108
6660 3
2338
7383 3
2568
8105 3
2792
8828 3
3022
9550 3
3252 10273 3 3482 10996 3
LT
LC
1150
+5 - 3
180 2
1200
+5 - 3
180
+3 - 2
1250
+5 - 3
190
+3 - 2
Figure 37: (Continued)
“a” Details
“b” Details
Gasket for
12
Intermediate Pipe Lubricant inlet
(Unit: mm) N o m in a l D ia
a
b
tC
t1
t2
1000 18 1100
125
60
65
9 2 .5
1200
6
4 .5
26 21
9
1350 1500
6
1650 140
65
75
1 0 2 .5
30
2 4 .5
6
1800 2000 9 2200 12 2400 2600 150
70
80
34
110
3 0 .5
9
9
2800 3000
Notes:
1. π・D0 is the external circumference of the collar. This is the same as D0 = Dc + 2Tc 2. π・D1 is the circumference of the base of the groove for rubber gasket. 3. The difference of maximum and minimum measurements of effective length shall be within 3mm. 4. The positions and quantity of grout holes may be altered as necessary.
85
4. RUBBER RING 4.1
CLASSIFICATION As shown in Figure 38, rubber rings are categorized in accordance with Standard Pipe and Type-S Intermediate Pipe, and Type-T Intermediate Pipe use. In addition, rubber rings for Standard Pipe and Type-S Intermediate Pipe are sub-categorized for fixing positions; namely, for connection, and for jointing. Table 38: Classification of Rubber Rings
Classification
Code
For Standard Pipe
Connection
EWSG
For Type-S Intermediate Pipe
Jointing
EWTG
For Type-T Intermediate Pipe
EWMG
Range of Nominal Diameter 800 ~ 3000 1000 ~ 3000
Note: For Nominal Diameters 800 ~ 1200, “Code” shall be ENWSG and ENWTG
For Standard Pipe
Rubber Ring for Jointing Rubber Ring for Connection
For Intermediate Pipes Rubber Ring for Jointing Rubber Ring for Connection
Rubber Ring Intermediate Pipe
S-Type Intermediate Pipe Standard Pipe
4.2
Cushion Rings
T-Type Intermediate Pipe Standard Pipe
Quality 4.2.1 Appearance Rubber ring shall be free of cuts, cracks, air bubbles, impurities or other elements that are detrimental to its functional use.
86
4.2.2 Physical Properties Physical properties of rubber ring shall be in accordance with JIS K 6353 (Rubber Goods for Water Works).
4.3
Shape, Dimensions and Dimensional Tolerances The shape, dimensions and dimensional tolerances of rubber ring shall be in accordance with Figure 39. Figure 39: Shape, Dimensions and Dimensional Tolerances of Rubber Ring for Standard Pipe and Type-S Intermediate Pipe (Unit: mm) Rubber Ring for Connection
Rubber Ring for Jointing
(Unit: mm) Rubber Ring for Connection
Nominal Diameter
B
800 ~ 1200
26 1
1350 ~ 2200
31 1
H
b1
b2
b3
h1
h2
28
6
8
8
7
Length L (%)
+ 0.5
15.5 -
0
85 1 of Rubber
+ 0.5
33
19 -
6
8
11
9
Ring Seat
0
Circumference 2400 ~ 3000
35 1
+ 0.5
22
37 -
6
0
87
8
12
10
Figure 39: (Continued) (Unit: mm) Rubber Ring for Jointing
Nom. Dia.
B
800 ~ 1200
26 1
H
h1
h2
h3
a
b
c
d
e
j
k
R
10
5
5
3
9
9
2
4
3
5
50
-
0
85 1 of
+ 0.5
30 1
20
15 -
7
5
4
11
12
2
4.5
3
7
60
Rubber
0
Ring Seat
2200 2400 ~
L (%)
+ 0.5
15.5
1350 ~
Length
Circumf’e
+ 0.5
34 1
23
16 -
8
6
4.5
12
13
2.5
5
3.5
9
70
0
3000
for Type-T Intermediate Pipe
(Unit: mm) Nom. Dia.
B
1000 ~ 1200
26 1
1350 ~ 2200
30 1
H
h1
h2
6
7
a
b
R
Length L (%)
+ 0.5
13 -
3
9
15
0
90 1 of Rubber
+ 0.5
19
9 -
10
4
11
Ring Seat
16
0
Circumference 2400 ~ 3000
34 1
+ 0.5
11.5
22.5 -
11
4.5
12
18
0
5. OTHERS
Matters not contained in this Appendix shall be referred to in JWJPAS J-2 Standard.
88