MITSUBISHI ELENESSA ENCODER CALIBRATION



1. Open the HN panel on the top floor.



Using a special key



2. Set the manual / automatic switch to manual use of the panel



3. Set Rotary switches as follows SET0=”D” SET1=”0”



4. Press switch SW1Δ DOWN and HOLD IN THIS STATE FOR 4 SECONDS. Display 7SEG will blink AD. (Will be displayed on display 2 and 1)



5. Then put the elevator down on the inspection by pressing RUN and hold the DN button until the display shows the floor number



7 The display will show any floor number, but this number is not the actual number where the cab is located - this will mean that the encoder calibration was successful. It will show as below. (for example, this photo shows the 02second landing)



6. After encoding the encoder calibration, turn OFF the power, and then turn it ON again. 7. Switch the power and turn on the system (initial installation or training).



New PCB replacement; P1 PCB / CPU Board Sometimes the elevator engine makes an unusual noise or makes a jerk, so it’s time to change the cable or unload what you are going to carry.



It is necessary to check the system.