MP5S/MP5Y/MP5W Series



Pulse Meter



High Performance, Digital Panel Meter



(A) Photoelectric Sensors



Features



3  types of operation mode are added. (total 16 types of operation mode) Frequency/Revolutions/Speed, Passing speed, Cycle, Passing time, Time interval, Time differential , Absolute ratio, Error ratio, Density, Error, Length measurement 1, Length measurement 2, Interval, Accumulation, Addition/Subtraction-individual input, Addition/ Subtraction-phase difference input Various output models Relay triple/quintuple output, NPN/PNP open collector quintuple output, BCD dynamic output, PV transmission output (current output), RS485 communication output (changed Modbus RTU) Various functions Selectable NPN solid state/contact input, PNP solid state/contact input, prescale, delay monitoring, hysteresis, auto-zero time setting, lock setting, data bank function (MP5W series) Max. display range: -19999 to 99999 Various display units rpm, rps, Hz, kHz, sec, min, m, mm, mm/s, m/s, m/min, m/h, ℓ/s, ℓ/min, ℓ/h, %, counts, etc.



Shaded parts ( ) are changed and added functions from previous MP5.



(C) Door/Area Sensors (D) Proximity Sensors (E) Pressure Sensors



MP5S



(F) Rotary Encoders (G) Connectors/ Connector Cables/ Sensor Distribution Boxes/Sockets (H) Temperature Controllers



MP5Y



MP5W



(I) SSRs / Power Controllers



Please read “Safety Considerations” in operation manual before using.



(J) Counters



Ordering Information



MP 5 Y - 4 N Output



(K) Timers



S



N



Y



N 1 2 3 4 5 6



Indicator NPN open collector quintuple output PNP open collector quintuple output Indicator Indicator Indicator Relay triple output (H, GO, L)



BCD dynamic output PV transmission output (current output) RS485 communication output -



N



-



1 2



Indicator Relay quintuple output (HH, H, GO, L, LL) Relay triple output (H, GO, L) NPN open collector quintuple output



4



NPN open collector quintuple output



PV transmission output (current output)



5 8



PNP open collector quintuple output NPN open collector quintuple output



PV transmission output (current output) RS485 communication output



9



PNP open collector quintuple output



RS485 communication output



W



Size Digits Item



2



24VAC 50/60Hz, 24-48VDC



4



100-240VAC 50/60Hz



S Y W



DIN W48×H48mm DIN W72×H36mm DIN W96×H48mm



5



99999 (5-digit)



MP



Pulse meter



Sub output (display value output) -



(L) Panel Meters



Main output (comparative value output) Indicator



A



Power supply



(B) Fiber Optic Sensors



-



(M) Tacho / Speed / Pulse Meters (N) Display Units (O) Sensor Controllers (P) Switching Mode Power Supplies (Q) Stepper Motors & Drivers & Controllers



BCD dynamic output



(R) Graphic/ Logic Panels (S) Field Network Devices (T) Software



M-7



MP5S/MP5Y/MP5W Series Specifications Series Display method Character size Display range AC voltage Power supply AC/DC voltage Power consumption



AC voltage AC/DC voltage



Permissible voltage range External power supply Sub power supply Input frequency



Input method



Measurement range Measurement accuracy (23℃±5℃) Display cycle Operation mode



Output



Prescale function Hysteresis Relay triple Relay quintuple Main NPN/PNP open collector quintuple BCD dynamic Sub PV transmission Communication Memory retention Insulation resistance Dielectric strength Noise immunity Mechanical Vibration Malfunction Mechanical Shock Malfunction Mechanical Relay life cycle Electrical Ambient temp. Environment Ambient humi. Approval ※2 Weight



MP5S MP5Y MP5W 7-segment LED (zero blanking method) W4×H8mm W7×H14mm -19999 to 99999 100-240VACᜠ 50/60Hz 24VACᜠ 50/60Hz, 24-48VDCᜡ Max. 7.5VA Max. 9VA Max. 15VA (100-240VACᜠ 50/60Hz) (100-240VACᜠ 50/60Hz) (100-240VACᜠ 50/60Hz) Max. 6VA (24VACᜠ 50/60Hz), Max. 7VA (24VACᜠ 50/60Hz), Max. 11VA (24VACᜠ 50/60Hz), max. 4.5W (24-48VDCᜡ) max. 6.2W (24-48VDCᜡ) max. 7W (24-48VDCᜡ) 90 to 110% of rated voltage Max. 12VDCᜡ ±10% 80mA Max. 24VDCᜡ 30mA ·Solid state input 1: max. 50kHz (pulse width: min. 10㎲) ·Solid state input 2: max. 5kHz (pulse width: min. 100㎲) ※For F7, F8, F9, F10 operation mode, max. 1kHz (pulse width: min. 500㎲) ·Contact input: max. 45Hz (pulse width: min. 11ms) [Voltage input] High: 4.5-24VDCᜡ, Low: 0-1VDC, Input impedance: 3.9kΩ [No-voltage input] Short-circuit impedance: Max. 80Ω, Residual voltage: Max. 1VDC, Open-circuit impedance: Min. 100kΩ : 0.0005Hz to 50kHz ·Operation mode F1, F2, F7, F8, F9, F10 : 0.01 to max. of each time range ·Operation mode F3, F4, F5, F6 : 0 to 99999 ·Operation mode F11, F12, F13, F16 : -19999 to 99999 ·Operation mode F14, F15 : F.S.±0.05%rdg±1-digit ·Operation mode F1, F2, F7, F8, F9, F10 : F.S.±0.01%rdg±1-digit ·Operation mode F3, F4, F5, F6 OFF (for F2, F16 operation mode), 0.05, 0.5, 1, 2, 4, 8 sec (same as update output cycle) Frequency/Revolutions/Speed (F1), Passing speed (F2), Cycle (F3), Passing time (F4), Time interval (F5), Time differential (F6), Absolute ratio (F7), Error ratio (F8), Density (F9), Error (F10), Length measurement 1 (F11), Interval (F12), Accumulation (F13), Addition/Subtraction-individual input (F14), Addition/Subtraction-phase difference input (F15), Length measurement 2 (F16) Direct input method (0.0001×10-9 to 9.9999×109) ※1 0 to 9999 250VACᜠ 3A resistive load 250VACᜠ 3A resistive load -



Max. 30VDCᜡ 30mA



Max. 30VDCᜡ 30mA DC4-20mA/DC0-20mA max. load 500Ω RS485 communication output (Modbus RTU method) Non-volatile memory (number of inputs: 100,000 operations) Over 100MΩ (at 500VDC megger) 2,000VAC 60Hz for 1 min ±2kV the square wave noise (pulse width: 1㎲) by the noise simulator 0.75mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 1 hour 0.5mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 10 min 300m/s² (approx. 30G) in each X, Y, Z direction for 3 times 100m/s² (approx. 30G) in each X, Y, Z direction for 3 times Min. 10,000,000 operations Min. 100,000 operations (250VAC 3A resistive load) -10 to 50℃, storage: -20 to 60℃ 35 to 85%RH, storage: 35 to 85%RH Approx. 191g (approx. 132g)



Approx. 230g (approx. 140g)



※1: Setting range will vary depending on the decimal point. ※2: The weight includes packaging. The weight in parenthesis is for unit only. ※Environment resistance is rated at no freezing or condensation.



M-8



Approx. 334g (approx. 210g)



Pulse Meter Connections



(A) Photoelectric Sensors



※Terminal connections differ by power supply and output type of each series and model.



MP5S Series



Brown



Blue



Black



Black



(B) Fiber Optic Sensors



8



9



(C) Door/Area Sensors



INA INB +12V 0V HOLD/RESET



6 ※1: Operation mode F1 to F12 : display value HOLD Operation mode F13 to F16 : display value RESET ※2: Model Source



MP5S-4N



10



11



(E) Pressure Sensors



12



1



24-48VDC 24VAC 50/60Hz 100-240VAC 50/60Hz



MP5S-2N



7



(D) Proximity Sensors



※1



2



3



4



(F) Rotary Encoders (G) Connectors/ Connector Cables/ Sensor Distribution Boxes/Sockets



5



(H) Temperature Controllers



- + ※2 SOURCE



(I) SSRs / Power Controllers



MP5Y Series Power/Input Terminal (Common)



(J) Counters



※MP5Y- N (indicator) only has 'Power/Input terminals'.



Black Black



1



2



INA



INB



(K) Timers



Blue Brown



3



4



5



0V HOLD/RESET



6



7



+12V



※1



-



+



SOURCE



(L) Panel Meters



※1: O  peration mode F1 to F12 : display value HOLD Operation mode F13 to F16 : display value RESET ※2: Model Source 24-48VDC MP5Y-2 24VAC 50/60Hz 100-240VAC MP5Y-4 50/60Hz



(M) Tacho / Speed / Pulse Meters (N) Display Units (O) Sensor Controllers



※2



(P) Switching Mode Power Supplies



O  utput Connector (MP5Y- 1 to 5)



(Q) Stepper Motors & Drivers & Controllers



※Hirose connector: HIF3BA-10PA-2.54DS ※Hirose connector socket: HIF3BA-10D-2.54R (sold separately) ※Hirose connector socket is not included. Contact a hirose connector dealer regarding sockets and cables.



● MP5Y- 1 (NPN open collector output)



● MP5Y- 2 (PNP open collector output)



MAIN OUT (NPN OPEN COLLECTOR) 30VDC 30mA



MAIN OUT (PNP OPEN COLLECTOR) 30VDC 30mA



GO



HH



LL



GO



HH



(T) Software



4



6



8



10



2



4



6



8



10



1



3



5



7



9



1



3



5



7



9



H



L



COM



H



(S) Field Network Devices



LL



2



COM



(R) Graphic/ Logic Panels



L



M-9



MP5S/MP5Y/MP5W Series ● MP5Y- 3 (BCD dynamic output)



● MP5Y- 4 (PV transmission output)



BCD OUT (NPN OPEN COLLECTOR) 30VDC 30mA A



C



D0



D2



DC4-20mA/DC0-20mA (+) Load 500Ω Max.



D4



2



4



6



8



10



2



4



6



8



10



1



3



5



7



9



1



3



5



7



9



COM



B



D1



D



D3



(-)



※Autonics display unit (DS/DA Series) is recommended for stable minus (-) sign display.



●Output Terminal (MP5Y- 6)



● MP5Y- 5 (RS485 communication otuput)



● MP5Y- 6 (Relay triple output)



RS485 B(-)



2



4



6



8



10



1



3



5



7



9



8



9



10



11



H



12 13 14 15



GO



L



CONTACT OUT: 250VAC 3A RESISTIVE LOAD



RS485 A(+)



MP5W Series ●Power/Input Terminal (Common) ※MP5W- N (indicator) only has 'Power/Input terminals'.



Black Black



※1: Operation mode F1 to F12 : display value HOLD Operation mode F13 to F16 : display value RESET ※2: Model Source 24-48VDC MP5W-2 24VAC 50/60Hz 100-240VAC MP5W-4 50/60Hz



1 INA



2 INB



Blue



3



4



5



Brown



6



7



0V



0V ※1



HOLD/RESET



●Output Terminal (MP5W- A/1)



9 - + ※2 SOURCE



BANK



● MP5W- A (Relay quintuple output)



8



+12V



● MP5W- 1 (Relay triple output)



CONTACT OUT: 250VAC 3A RESISTIVE LOAD



CONTACT OUT: 250VAC 3A RESISTIVE LOAD



H



10



11



12



13



14



15



HH



H



GO



L



LL



COM



M-10



10



GO



11



12



L



13



14



15



Pulse Meter Output Connector (MP5W- 2/4/5/8/9)



(A) Photoelectric Sensors



※Hirose connector: HIF3BA-20PA-2.54DS ※Hirose connector socket: HIF3BA-20D-2.54R (sold separately) ※Hirose connector socket is not included. Contact a hirose connector dealer regarding sockets and cables. ※1: Sub power supply ※2: POL signal turns ON when the display value is a minus (-) value.



(B) Fiber Optic Sensors



● MP5W- 2 (NPN open collector+BCD dynamic output) MAIN OUT (NPN OPEN COLLECTOR) 30VDC 30mA +24VDC ※ 30mA Max. 1 LL HH GO D B



(C) Door/Area Sensors



D1



D3



DOT COM2



2



4



6



8



10



12



14



16



18



20



1



3



5



7



9



11



13



15



17



19



COM



H



L



A



0V



(D) Proximity Sensors (E) Pressure Sensors (F) Rotary Encoders



※2



C D4 D0 POL D2 BCD OUT (NPN OPEN COLLECTOR) 30VDC 30mA



(G) Connectors/ Connector Cables/ Sensor Distribution Boxes/Sockets



※Autonics display unit (DS/DA Series) is recommended for stable minus (-) sign display.



● MP5W- 4 (NPN open collector+PV transmission output)



● MP5W- 5 (PNP open collector+PV transmission output) MAIN OUT (PNP OPEN COLLECTOR) 30VDC 30mA



MAIN OUT (NPN OPEN COLLECTOR) 30VDC 30mA +24VDC ※ 30mA Max. 1 HH GO LL



HH



(+)



2



4



6



8



10



12



14



16



18



20



1



3



5



7



9



11



13



15



17



19



COM H



L



0V



1 COM



6



3 H



5 L



8 7 0V



4



6



1



3



5



(K) Timers



(L) Panel Meters



L



(M) Tacho / Speed / Pulse Meters (N) Display Units



● MP5W- 9 (PNP open collector+RS485 comm. output)



MAIN OUT (NPN OPEN COLLECTOR) 30VDC 30mA +24VDC ※ 30mA Max. 1 HH GO LL



4



2



COM H



10 9



RS485 B(-)



12 11



14 13



16 15



18 17



(I) SSRs / Power Controllers



(J) Counters



LL



(-) DC4-20mA/DC0-20mA (Load 500Ω Max.)



● MP5W- 8 (NPN open collector+RS485 comm. output)



2



GO



(H) Temperature Controllers



20 19



(O) Sensor Controllers



MAIN OUT (PNP OPEN COLLECTOR) 30VDC 30mA HH



GO



(P) Switching Mode Power Supplies



LL



2



4



6



(Q) Stepper Motors & Drivers & Controllers



1



3



5



(R) Graphic/ Logic Panels



COM H



L



(S) Field Network Devices



A(+) RS485



(T) Software



M-11



MP5S/MP5Y/MP5W Series Dimensions



(unit: mm)



※Nameplate design is changed from the previous MP5. ※Side dimensions of MP5Y/W differ by output type.



●MP5S Series



10



90



45



48



●MP5Y Series



MP5Y- 1/2/3/4/5



72



89.5



MP5Y- 6



14.5



15.3



36



30



6



10.5



10.5



※M  P5Y- N (indicator) does not include the shaded part (output hirose connector or output terminal).



MP5W- 2/4/5/8/9



96



MP5W- A/1 10.5



14.5



89.5



6



48



45



●MP5W Series



10.5



10.5 ※MP5W- N (indicator) does not include the shaded part (output hirose connector or output terminal).



Panel cut-out dimensions A



(unit: mm) D



MP5S MP5Y MP5W



C



C



D



45.5 68 92



+0.5 0



+0.7 0 +0.8 0



45.5 31.5 45



+0.5 0 +0.5 0



+0.6 0



For MP5Y/W



41 4.2



B



Min. 55 Min. 62 Min. 91 Min. 40 Min. 116 Min. 52



3



3.9



 Bracket For MP5S



A



15



12.2 16.4 48.6



M-12



42.2 45.4 47.8 61.64



73



6



4 1



9.5



0.82



0.2±0.2



4.5



45.4 50 61



12±0.2



30



10



B



Series



Size



M3



Pulse Meter Unit Description



●MP5S Series



●MP5Y Series



(A) Photoelectric Sensors



●MP5W Series 4



4



(B) Fiber Optic Sensors



1



1



1



(C) Door/Area Sensors (D) Proximity Sensors



2



3



2 3 1: Display component Displays current value in RUN mode. Alternately displays setting parameters and corresponding value in SETTING mode. 2:  key In RUN mode, press the key once to check max./min. value. In RUN mode, hold the key for over 2 sec to enter parameter groups. 3:  , , key Select parameter groups, and select or setting values in the corresponding parameters. 4: O  utput status indicator



2



(E) Pressure Sensors



3



(F) Rotary Encoders (G) Connectors/ Connector Cables/ Sensor Distribution Boxes/Sockets



Sold Separately



Communication converter SCM-WF48



(Wi-Fi to RS485·USB wireless communication converter)



(H) Temperature Controllers



SCM-38I



SCM-US48I



(RS232C to RS485 converter)



(USB to RS485 converter)



(I) SSRs / Power Controllers



(J) Counters



(K) Timers



(L) Panel Meters



Display Units (DS/DA-T Series)



(M) Tacho / Speed / Pulse Meters



DS/DA-T Series (RS485 communication input type display unit)



(N) Display Units



DS16- T DS22/DA22- T DS40/DA40- T DS60/DA60- T ※Connect RS485 communication input type display unit (DS/DA-T Series) and RS485 communication output model of MP5Y/MP5W Series, the display unit displays present value of the device without PC/PLC.



(P) Switching Mode Power Supplies



Input Specifications



Input Specifications



1. Input signal



(Q) Stepper Motors & Drivers & Controllers



Standard duty ratio of input signal is 1:1. ON (1) Solid state input 1 OFF Input frequency: Max. 50kHz (ON/OFF pulse width: min. 10㎲ of each) Pulse width (2) S  olid state input 2 OFF ON Input frequency: Max. 5kHz (ON/OFF pulse width: min. 100㎲ of each) ※For F7, F8, F9, F10 operation mode, max. 1kHz (ON/OFF pulse width: min. 500㎲ of each) T (3) Contact input ① Input frequency: Max. 45Hz (when each ON/OFF pulse width is over 11ms) ※T: s ingle cycle of input signal ② Contact specifications: 12VDC, stable switching of load current as small as 5mA



(R) Graphic/ Logic Panels (S) Field Network Devices



2. Input type [IN-A, IN-B]



(T) Software



IN 0V (COM)



MP5



3.9kΩ



Sensor circuit



Sensor circuit



0V (COM)



3.9kΩ



Sensor circuit



IN



Sensor circuit



Sensor circuit



MP5 allows selection between NPN input (solid state/contact) or PNP input (solid state/contact). (1) NPN input type (2) PNP input type ①Contact ②NPN voltage ③NPN open collector ①Contact ②PNP voltage ③PNP open collector output type sensor output type sensor output type sensor output type sensor MP5 +12V +12V Sensor circuit



(O) Sensor Controllers



M-13



MP5S/MP5Y/MP5W Series Output Specifications



1. Relay output



① Output: Comparative or alarm output (refer to " Output Modes") ② Output type: Relay ③ Contact capacity: 250VAC 3A resistive load ④ Life cycle: [Mechanical] min. 10,000,000 operations (switching frequency 180 operations/min) [Electrical] min. 100,000 operations (3A 250VAC, 30VDC resistive load) (switching frequency 20 operations/min)



2. Transistor output



① Output: Comparative output or alarm output (refer to " ② Output type: NPN/PNP open collector ③ Rated load voltage: 30VDC ④ Max. load current: 30mA



Output Modes")



3. BCD dynamic output (negative logic)



① Output: present value ② Output signal: BCD data (A, B, C, D, DOT) ← A: lowest bit, DOT: highest bit Digit data (D0, D1, D2, D3, D4) ← D0: lowest digit, D4: highest digit ③ Output type: NPN open collector ④ Rated load voltage: 30VDC ⑤ Max. load current: 30mA ⑥ Dynamic COM cycle (T) = 40ms



E.g.) To display value = 125.89 by BCD dynamic output 104-digit 100-digit PV display value



1



2



5.



8



9



A B



BCD Data



C D DOT D0 0.1ms



D1 Digit



D2 D3 D4



5ms



8ms



40ms



4. PV transmission output



① Application: transmit measured value ② Function: transmit measured value within setting range of high-limit output [FS-H] to low-limit output [FS-L] after conversion into DC4-20mA or DC0-20mA current. ③O  utput range of high/low-limit ·High-limit [FS-H] range: From min. value to max. value within measurement range ·Low-limit [FS-L] range: From min. value to max. value within measurement range ([FS-H]≥[FS-L]+1) (1) DC4-20mA transmission output (2) DC0-20mA transmission output ① Transmit measured value within setting range of high-limit ① Transmit measured value within setting range of high-limit output [FS-H] to low-limit output [FS-L] after conversion output [FS-H] to low-limit output [FS-L] after conversion into into DC4-20mA current. DC0-20mA current. ② Resistive load: Max. 500Ω ② Resistive load: Max. 500Ω ③ Resolution: 8000 divisions ③ Resolution: 10,000 divisions Diplay value FS-H



Display value FS-H



FS-L Set [FS-L] and [FS-H] and the output is DC4-20mA. If the setting width between [FS-L] and [FS-H] is lower than 8000 divisions, the resolution is also reduced.



FS-L 20mA



4mA



Set [FS-L] and [FS-H] and the output is DC0-20mA. If the setting width between [FS-L] and [FS-H] is lower than 10,000 divisions, the resolution is also reduced.



20mA 0mA



5. RS485 communication output Comm. protocol Connection type Application standard Max. connection Synchronous method Comm. method Comm. distance



Modbus RTU RS485 Compliance with EIA RS485 31 units (address: 01 to 99) Asynchronous Two-wire half duplex Max. 800m



Communication Speed



2400, 4800, 9600 (default), 19200, 38400 bps



Communication response time Start Bit Data Bit Parity Bit Stop Bit



5 to 99ms (default: 20ms) 1-bit fixed 8-bit fixed None (default), Even, Odd 1, 2-bit (default)



※For more information about RS485 communication output specifications, refer to ' RS485 Communication Output'.



M-14



Pulse Meter Parameter Groups



(A) Photoelectric Sensors



Parameter 0 group



(max./min. monitoring value)



RUN mode



2 sec



HOLD/RESET



3 sec



(B) Fiber Optic Sensors







※Operation mode F1 to F12 : display value HOLD Operation mode F13 to F16 : display value RESET



(C) Door/Area Sensors (D) Proximity Sensors



Parameter 1/2/3 group ※Press the , , keys to select or set the desired value. ※Press the key once after changing the setting value, to save the setting value and move to the next parameter. ※Hold the key for 1.5 sec at any parameters to return to the select parameter group mode. ※Hold the key for 3 sec to save the setting value and return to RUN mode after changing the setting value. ※If there is no key input for 60 sec while setting the parameters, the new settings are ignored, and the unit will return to RUN mode with previous settings. ※The dotted line parameters may not appear depending on output specifications or other parameter settings. Please refer to ' Operation Mode by Parameter Group'. ※1: Each parameter and corresponding setting value will flash alternately every 0.5 sec.



● Parameter 0 group



(E) Pressure Sensors (F) Rotary Encoders (G) Connectors/ Connector Cables/ Sensor Distribution Boxes/Sockets (H) Temperature Controllers (I) SSRs / Power Controllers



RUN mode



(J) Counters



PStHH



PSt H



PSt L



PStLL



Flashes ※1 alternately



99999



99999



HH comparative value ※Does not appear in F output mode



H comparative value



(K) Timers



※The parameters are identical to [PStHH], [PSt H], [PSt L], [PStLL] of parameter 2 group and the setting values will be linked. ●Setting range by operation mode Operation mode Setting range F1, F2, F7, F9, F11, 0 to 99999 F12, F13, F16 F3, F4, F5, F6



00000



00000



L comparative value



LL comparative value ※Does not appear in F output mode,



0 to setting time range



`9999 to 99999 F8, F10, F14, F15 (the setting range varies depending on the decimal point setting.) ※Only appears in comparative value setting models.



(L) Panel Meters (M) Tacho / Speed / Pulse Meters (N) Display Units (O) Sensor Controllers (P) Switching Mode Power Supplies (Q) Stepper Motors & Drivers & Controllers



hPEK



99999



Max. monitoring value



(R) Graphic/ Logic Panels



※Resetting monitoring value :H  old the key for over 2 sec (reset current value)



lPEK



`9999



(S) Field Network Devices



Min. monitoring value



(T) Software



M-15



MP5S/MP5Y/MP5W Series ● Parameter 1 group 2 sec



RUN mode 3 sec



MODE



Flashes ※ alternately 1



PARa1



F ㄹ 1



PARa2



Operation mode ●Setting range: F1 to F16



●Setting range Parameter Input sensor type NPnhF NPN solid state input 1 NPnmF NPN solid state input 2 NPnlF NPN contact input PNphF PNP solid state input 1 PNpmF PNP solid state input 2 PNplF PNP contact input



IN-A



NPnhF



Sensor type of input A



IN-B



NPnhF



Sensor type of input B



OUT-T



STARD



●Setting range Parameter Output mode STARD S (Standard) Output mode OUT-H H (High) OUT-L L (Low)



HYS



0001



GUARD



fDEFY STArT



PARa3



Parameter OUT-B OUT-I OUT-F



Output mode B (Block) I (One-shot) F (Deflection)



Output hysteresis ●Setting range: 0000 to 9999 (the setting range varies depending on the decimal point setting.)



LL, L comparative output limit function



9(9 Start compensation timer function & compensation time ●Setting range: )0 to 9(9 (sec)



AUToA



999(9



Auto-zero time for input A ●Setting range: )1 to 999(9 (sec)



M-16



AUToB



999(9



MEMO



OFF



Auto-zero time for input B



Memory retention ●Setting range: ㅒㅜON, OFF



※Does not appear in indicator models.



Pulse Meter ● Parameter 2 group



RUN mode



2 sec



PARa1



PARa2



(A) Photoelectric Sensors



PARa3



(B) Fiber Optic Sensors



3 sec



pBANK



Flashes ※ alternately 1



1



(C) Door/Area Sensors



Data bank ●Setting range: 1, 2 ※Only appears in MP5W.



(D) Proximity Sensors



DOT



tUNT



00000



Decimal point location of display value ●Setting range: 00000, 000)0, 00)00, 0)000, )0000



tSEC



99(99



tMIN



99(99



Time unit and range ●Setting range tSEC (sec) 99(99 999.99s 999(9 9999.9s 9(5(9 99m 59.9s (5(59 9h 59m 59s 99999 99999s



PStHH



99999



HH comparative value ※Does not appear in F output mode



PSt H



99999



H comparative value



PSt L



PStLL



PScaH



00000



L comparative value



00000



LL comparative value ※Does not appear in F output mode



^0000



PScaY



10 01



PScbH



^0000



PScbY



10 01



(E) Pressure Sensors (F) Rotary Encoders



tMIN (min) 99(99 999.99m 999(9 9999.9m 9(5(9 99h 59.9m 99(59 999h 59m 99999 99999m



(G) Connectors/ Connector Cables/ Sensor Distribution Boxes/Sockets (H) Temperature Controllers



※The parameters are identical to [PStHH], [PSt H], [PSt L], [PStLL] of parameter 0 group and the setting values will be linked. ●Setting range by operation mode Operation mode Setting range F1, F2, F7, F9, F11, 0 to 99999 F12, F13, F16 F3, F4, F5, F6 0 to set time range `9999 to 99999 F8, F10, F14, F15 (the setting range varies depending on the decimal point setting.) ※Only appears in comparative value setting models.



(I) SSRs / Power Controllers



(J) Counters



(K) Timers



(L) Panel Meters (M) Tacho / Speed / Pulse Meters (N) Display Units



Prescale mantissa (X) of input A ●Setting range: )0001 to (9999



(O) Sensor Controllers (P) Switching Mode Power Supplies



Prescale exponent (y) of input A ●Setting range: 10 - 9 (10-9) to 10 09 (109)



(Q) Stepper Motors & Drivers & Controllers



Prescale mantissa (X) of input B ●Setting range: )0001 to (9999



(R) Graphic/ Logic Panels (S) Field Network Devices



Prescale exponent (y) of input B ●Setting range: 10 - 9 (10-9) to 10 09 (109)



(T) Software



DISpT



)05



COUnB



99999



Display cycle of measured value ●Setting range: )05, )5, 1, 2, 4, 8 (sec) ※Setting range in operation mode F2, F16 : OFF, )05, )5, 1, 2, 4, 8 (sec) Setting value of input B ●Setting range: 1 to 99999



M-17



MP5S/MP5Y/MP5W Series ● Parameter 3 group



RUN mode



2 sec



PARa1



PARa2



PARa3



3 sec



●Setting range by operation mode Operation mode Setting range F1, F2, F7, F9, F11, F12, 0 to 99999 F13, F16 F3, F4, F5, F6 0 to set time range `9999 to 99999 F8, F10, F14, F15 (the setting range varies depending on the decimal point setting.) ※Only appears in PV transmission output models.



99999



High-limit value of PV transmission output



FS-L



00000



Low-limit value of PV transmission output



MA



4-20



ADDR



01



B ㅜㅠ PS



9600



Communication speed ●Setting range: 9600, 19200, 38400, 2400, 4800 (bps)



P ㅜ RTY



NONE



Communication parity bit ●Setting range: NONE (none), EVEN (even), ODD (odd)



FS-H



STP



M-18



Flashes ※ alternately 1



2



RSwT



20



COmW



D ㅇ ISA



LOC



OFF



Current output specifications ●Setting range: 4-20, 0-20 Communication address ●Setting range: 01 to 99



※Only appears in RS485 comm. output models.



Communication stop bit ●Setting range: 1, 2



Communication response wait time ●Setting range by communication speed Communication speed (unit: bps) 2400 4800 9600, 19200, 38400



Setting range (unit: ms) 16 to 99 8 to 99 5 to 99



Communication write ●Setting range: ENA (enable), DISA (disable)



Lock ●Setting range Parameter OFF LOc0 LOc1 LOc2 LOc3



Function Unlock Lock all Parameter 1/2/3 lock Parameter 2/3 lock Parameter 3 lock



Pulse Meter Operation Mode by Parameter Groups Parameter



Operation mode PStHH



0 group



PSt H PSt L



F1



F2



F3



F4



F5



F6



F7



( : parameter display, X: no parameter display) F8



F9



F10



F11



F12



F13



F14



F15



F16



※1 ※2



(B) Fiber Optic Sensors (C) Door/Area Sensors



Appears in all operation modes (F1 to F16).



※2



(A) Photoelectric Sensors



※1



PSt LL



(D) Proximity Sensors



hPEK lPEK MODE IN-A



1 group



IN-B OUT-T HYS GVARD



(E) Pressure Sensors



Appears in all operation mode (F1 to F16). ※3 ※2



※4



※2



(F) Rotary Encoders (G) Connectors/ Connector Cables/ Sensor Distribution Boxes/Sockets



※2



AVToA



(H) Temperature Controllers



AVToB MEMO



(I) SSRs / Power Controllers



※Only appears in MP5W. Appears in all operation modes (F1 to F16).



pBANK DOT



(J) Counters



tUNT PStHH



2 group



PSt H PStLL PSt L



※1 ※2 ※2



(K) Timers



Appears in all operation modes (F1 to F16).



※1



(L) Panel Meters



PScaH



(M) Tacho / Speed / Pulse Meters



PScaY PScbH PScbY DISpT



(N) Display Units



※5



COUnB FS-H



(O) Sensor Controllers



※Only appears in PV transmission output models. Appears in operation modes (F1 to F16).



FS-L



(P) Switching Mode Power Supplies



ㅡMA 3 group



ADDR



(Q) Stepper Motors & Drivers & Controllers



BPS ※Only appears in RS485 comm. output models. Appears in all operation modes (F1 to F16).



PRTY STP



(R) Graphic/ Logic Panels



REwT



(S) Field Network Devices



COmW LOC ※1: Only appears in only for quintuple output models. ※2: Only appears in triple, quintuple output models. ※3: The settings for IN-B and IN-A are applied. ※4: ( ) F output mode [OUT-F] cannot be set. ※5: ( ) setting range: OFF, )05, )5, 1, 2, 4, 8



(T) Software



Monitoring delay function by output mode Output mode Parameter Comparative output limit Start compensation timer



S mode H mode L mode B mode I mode F mode STARD OVT-; OVT-L OVT-B OVT-I OVT-F



M-19



MP5S/MP5Y/MP5W Series Operation Modes [MODE] Select operation mode from operation mode[MODE]of parameter 1 group.. MP5 has 16 operation modes.



F1 Mode: Frequency/Revolutions/Speed



Measures the frequency of input A and displays the calculated frequency, revolutions, and speed. 1) Frequency (Hz)



=f×α



(α= 1[sec])



2) Revolutions (rpm)



=f×α



(α= 60[sec])



3) Speed (m/min)



=f×α



(α= 60L[sec])



※L: travel distance of conveyor belt of 1 pulse cycle[m] α: prescale value 60L For multiple objects, α = N



MP5 Encoder



Display value and display unit Display value Frequency Revolutions



Speed



Display unit



α (prescale value)



Hz



1



kHz



0.001



rps



1



rpm (default)



60



mm/sec



1,000L



cm/sec



100L



m/sec



1L



m/min



60L



km/hour



3.6L



Timing chart Input A t1



Hold input



t2



t3



t4



1 α 1 α t1 t2



Display



Display value



Passing speed



α (prescale value)



mm/sec



1,000L



cm/sec



100L



m/sec (default)



1L



m/min



60L



km/hour



3.6L



t6



1 α t5



1 α t6



MP5



Sensor B Sensor A



Timing chart



Display unit



t5



1 α t3



F2 Mode: Passing Speed Displays the passing speed between input A ON and input B ON. Passing speed (V) = f × α (α = L[m]) ※f : reciprocal of time [sec] between input A (sensor) ON and input B (sensor) ON. L: distance between input A (sensor) and input B (sensor) [m] α: prescale value



Display value and display unit



MP5



Input A Input B Hold input



ta t1



Display



t2 1 α t1



t3 1 t2 α



t4



t5 t6 t7 1 1 1 α α t6 t4 t7 α



1 t3 α



※ta: Return time (over 20ms)



F3 Mode: Cycle Displays the measured time from Input A ON to the next ON. Cycle (T) = t ※t: measurement time[sec]



Photoelectric sensor



Display value and display unit ([tUNT] of parameter 2) Display value



Display unit Sec



Min



999.99s (default) 999.99m Cycle



M-20



9999.9s



9999.9m



99m59.9s



99h59.9m



9h59m59s



999h59m



99999s



99999m



MP5



Timing chart Input A Hold input Display



t1



t2



t3



t1



t2



t4



t5 t3



t6 t5



t6



Pulse Meter F4 Mode: Passing Time



(A) Photoelectric Sensors



Measures the time from Input A ON to the next ON, and displays the passing time of the arbitrary distance. Passing time[sec]= t × α (α=



(B) Fiber Optic Sensors



L[m] ) Distance advanced in 1 pulse cycle [m]



※t : measured time[sec], L : arbitrary distance[m] α: prescale value



en



Display value and display unit ([tUNT] of parameter 2) Display value



Passing time



L:L



MIN



999.99s (default)



999.99m



9999.9s



9999.9m



99m59.9s



99h59.9m



9h59m59s



999h59m



99999s



99999m



(D) Proximity Sensors



MP5



Display unit SEC



(C) Door/Area Sensors



m] gth[



(E) Pressure Sensors



Timing chart Input A t1



Hold input Display



t2



t3



t4



t1 α



t2 α



t5



(F) Rotary Encoders



t6 t5 α



t3 α



t6 α



(G) Connectors/ Connector Cables/ Sensor Distribution Boxes/Sockets (H) Temperature Controllers (I) SSRs / Power Controllers



F5 Mode: Time Interval Displays measured time of Input A ON Time interval (T) = t ※t: measured time of input A ON [sec]



MP5 Motor



Display value and display unit ([tUNT] of parameter 2) Display value



Time interval



(J) Counters



Stamp



Display unit SEC



MIN



999.99s (default)



999.99m



9999.9s



9999.9m



99m59.9s



99h59.9m



Hold input



9h59m59s



999h59m



Display



99999s



99999m



(K) Timers



Timing chart



(L) Panel Meters



Input A t1



ta



t2



ta



(M) Tacho / Speed / Pulse Meters



t3



t1



t3



t2



(N) Display Units



※ta: Return time (over 20ms)



(O) Sensor Controllers



F6 Mode: Time Differential Displays measured time from Input A ON to Input B ON. Time differential (T) = t (ta to tb) ※t (ta to tb): measured time from input A ON to input B ON [sec]



(Q) Stepper Motors & Drivers & Controllers



Display value and display unit ([tUNT] of parameter 2) Display value



Display unit SEC



Time difference



MIN



999.99s (default)



999.99m



9999.9s



9999.9m



99m59.9s



99h59.9m



9h59m59s



999h59m



99999s



99999m



(P) Switching Mode Power Supplies



MP5



Sensor B



(R) Graphic/ Logic Panels



Sensor A



Timing chart



(S) Field Network Devices



Input A Input B Hold input Display



ta t1



(T) Software



t2 t1



t3 t2



t4 t3



t5



t6 t4



t7 t6



t7



※ta: Return time (over 20ms)



M-21



MP5S/MP5Y/MP5W Series F7 Mode: Absolute Ratio



Measures and displays relative speed, amount, speed, etc. of input B against input A in percentage (%). Absolute ratio = (Input B / Input A) × 100% Frequency of input B[Hz] × Bα Absolute ratio = × 100[%] Frequency of input A[Hz] × Aα



Flow meter A



Flow meter B



MP5



Liquid



※Aα: Prescale value of input A, Bα: Prescale value of input B



Display value and display unit Display value



Display unit



Absolute ratio



%



※Hold: When the hold signal turns ON, the display value is maintained until the display cycle turns to hold OFF.



Timing chart Input A



fA



Input B



fB



Display =



Frequency of input B[Hz] × Bα × 100[%] Frequency of input A[Hz] × Aα



F8 Mode: Error Ratio



Measures and displays the relative rate of input B against the reference value of input A in percentage (%). Input B-Input A Error ratio = × 100[%] Input A



Conveyor A Conveyor B



(Frequency of input B [Hz] × Bα)Error ratio = (Frequency of input A[Hz] × Aα) × 100[%] Frequency of input A[Hz] × Aα ※Aα: prescale value of input A, Bα: prescale value of input B



Display value and display unit Display value



Display unit



Error ratio



%



MP5



Timing chart



Input A fA Input B



※Hold: When the hold signal turns ON, the display value is maintained until the display cycle turns to hold OFF.



fB



F9 Mode: Density



Measures and displays the density ratio (%) of input B against the total sum of input A and input B. Input B Density = × 100[%] Input A + Input B Frequency of Input B[Hz] × Bα Density = × 100[%] (Frequency of input A[Hz] × Aα) + (Frequency of input B[Hz] × Bα) ※Aα: Prescale value of input A, Bα: Prescale value of input B



Display value and display unit Display value



Display unit



Density



%



Flow meter A



MP5



Flow meter B



Liquid



Timing chart Input A fA Input B



※Hold: When the hold signal turns ON, the display value is maintained until the display cycle turns to hold OFF.



fB



F10 Mode: Error



Conveyor A



Measures and displays the error of input B against reference value of input A. Error = Input B - Input A Error = (Frequency of input B[Hz] × Bα) - (Frequency of input A[Hz] × Aα) ※Aα: prescale value of input A, Bα: prescale value of input B Display value and display unit Display value



Display unit



Error



END User setting



※Hold: When the hold signal turns ON, the display value is maintained until the display cycle turns to hold OFF.



MP5



Timing chart



Input A fA Input B fB



M-22



Conveyor B



Pulse Meter F11 Mode: Length Measurement 1



(A) Photoelectric Sensors



Measure and display the number of input A pulses during input B ON.



Input A



Length measurement = P × α ※P: Number of input A pulses, α: Prescale value



Display value and display unit Display value



Display unit Quantity (default) mm



Length measurement



cm m



(B) Fiber Optic Sensors



Photoelectric sensor



MP5



Timing chart Input A



Input B



(C) Door/Area Sensors



1 2 3 4 5 6



1 2



1 2 3 4 (D) Proximity Sensors



Input B tb



ta



Hold input



6 α



Display



2 α



4 α



※ta, tb: return time (over 20ms)



F12 Mode: Interval



Display value and display unit Display value



Interval



Display unit



Photoelectric sensor



Timing chart Input A



mm



Input B



m



(G) Connectors/ Connector Cables/ Sensor Distribution Boxes/Sockets (H) Temperature Controllers



Quantity (default) cm



(F) Rotary Encoders



MP5



Measures and displays the number of input A pulses from Input B ON to the next ON. Interval = P × α ※P: Number of input A pulses, α: Prescale value



1 2 3 4 5



1 2 3 4



(I) SSRs / Power Controllers



1 2 3



(J) Counters



ta



Hold input



(K) Timers



5×α



Display



4×α (L) Panel Meters



※ta: return time (over 20ms)



(M) Tacho / Speed / Pulse Meters



F13 Mode: Accumulation Measures and displays the counted value of input A pulses. Accumulation = P × α ※P: Number of input A pulses, α: Prescale value



(N) Display Units



MP5



Display value and display unit Display value



Display unit



Accumulation



Quantity[EA]



Operation



①Counts the number of input A pulses. ②Input B is an enable input signal. During ON, the quantity and display value of input A will be held, and during OFF input A will be re-counted. ③When RESET input is ON, the integrated counted value will be reset to "0".



(E) Pressure Sensors



(O) Sensor Controllers



Timing chart Input A Input B RESET Display 0



1



1



2



3



2 3



4



5 6



4



5 6



1



0



1



2 3



4



2 3 4



※α=1 display value



(P) Switching Mode Power Supplies (Q) Stepper Motors & Drivers & Controllers (R) Graphic/ Logic Panels (S) Field Network Devices (T) Software



M-23



MP5S/MP5Y/MP5W Series F14 Mode: Addition/Subtraction-Individual Input



MP5



Displays the counted value from added input A pulses and subtracted input B pulses. When there are two inputs simultaneously, it will not count. Addition/Subtraction = Input A × α - Input B × β ※α: Prescale value of input A, β: Prescale value of input B



Display value and display unit Display value



Display unit



Addition/ Subtraction (individual input)



Quantity



Operation and timing chart



Pulse of input A is added, and pulse of input B is subtracted.



Photoelectric Input A sensor



(addition)



Timing chart



H L H Input B L RESET H L Input A



Display 0



1



2 32



Display value and display unit Display value



Display unit



Up/Down counting (phase difference input)



Quantity



Display value



Display unit



Length measurement 2



Quantity[EA]



※If input A and input B are ON during initial power supply, it will not count and only count the number of rising edge. ※Display value is renewed depending on the display cycle [DISpT] setting.



M-24



2



3



2 1



Input B MP5



Timing chart H L H Input B L RESET H L Input A



0



1



2 3



2



1



0



1 2 0



Timing chart (e.g.) setting value of Input B=4



Measures and displays the number of pulses from input A until the value of input B reaches the set value. H Input A L Length measurement 2 = P × α (until the setting value of Input B) H Input B L ※P: Number of input A pulses, α: Prescale value



Display value and display unit



1



Input A



Display



F16 Mode: Length Measurement 2



0



※α, β=1 display value



F15 Mode: Addition/Subtraction- Phase difference input When input A is low, counting is added to the low of input B. When input A is low, counting is subtracted from the high of input B. Addition/Subtraction (phase difference) = Detects position and speed using A and B phases of encoder outputs as input.



Input B (subtraction)



1



2



1



2



3



4



1



2



3



H RESET L 1 2 3 4 0 1 2 3 4 5 6 7 0 1 2 3 4 5



Display Display



※1



0



7



※1: W  hen the display cycle [DISpT] setting is OFF, it will maintain the quantity of input A until the value of input B reaches the setting value B [COUnB].



Pulse Meter Output Modes [OUT-T]



(A) Photoelectric Sensors



MP5 Series supports 6 output modes. (There is no output mode in indicator models). Requirement for setting comparative value: (B output mode) LL