5 0 6 MB
R32
PANDUAN TEKNIS Unit Air Conditioner Split Seri A Wall Mounted Seri FTV-A
— Pendinginan Saja [50Hz] —
TM-3WM-J-ID-A1
Daftar Isi
Daftar Isi Tata Nama ........................................................................................................................................................... 1 Indoor ............................................................................................................................................................ 1 Outdoor ......................................................................................................................................................... 1 Line-up Produk .......................................................................................................................................... 2 Informasi Aplikasi ........................................................................................................................................... 3 Jangkauan Operasi .................................................................................................................................. 3 Diagram Sirkuit Refrigeran.................................................................................................................... 4 Panduan Instalasi ..................................................................................................................................... 5 Data Suara .......................................................................................................................................................... 9 Tingkat Tekanan Suara .......................................................................................................................... 9 Kurva NC ................................................................................................................................................... 10 Data Fisik dan Engineering ...................................................................................................................... 13 Data Performa ................................................................................................................................................. 15 Langkah Kalkulasi .................................................................................................................................. 15 Tabel Performa ........................................................................................................................................ 18 Garis besar & Dimensi .............................................................................................................................. 23 Diagram Pengkabelan ................................................................................................................................ 26 Servis & Perawatan ...................................................................................................................................... 29 Penyelesaian Masalah ................................................................................................................................ 30
Tata Nama
Tata Nama Indoor
FT V 15 A X V1 4 Wilayah 4: Indonesia Catu Daya V1: 220-240V 1 phase 50 Hz Negara Asal X: MALAYSIA Seri Produk A: Seri A Kapasitas* 15: 1500 Watt 35: 3500 Watt Refrigeran V: R32
20: 2000 Watt 50: 5000 Watt
25: 2500Watt 60: 6000 Watt
Model FT: Non Inverter Wall Mounted (Pendinginan)
Outdoor
R V 15 A X V1 4 Wilayah 4: Indonesia Catu Daya V1: 220-240V 1 phase 50 Hz Negara Asal X: MALAYSIA Seri Produk A: Seri A Kapasitas* 15: 1500 Watt 35: 3500 Watt Refrigeran V: R32
20: 2000 Watt 50: 5000 Watt
25: 2500 Watt 60: 6000 Watt
Model R: Unit Single Split Condensing (Pendinginan)
Keterangan
: Nilai kapasitas berdasarkan Tata Nama merupakan indikasi. Silakan mengacu pada Data Teknik dan Data Fisik untuk nilai kapasitas yang sebenarnya.
1
Tata Nama
Line-up Produk Unit Indoor FTV
Sirip
Penjernih Udara
PCB
Remot
Klasifikasi
Hidrofilik (Biru)
Filter Saranet
WMJ01B
BRC52A62 WMJ02B
Tata Nama
FTV15A
X
X
X
X
FTV20A
X
X
X
X
FTV25A
X
X
X
X
FTV35A
X
X
X
X
FTV50A
X
X
X
X
FTV60A
X
X
X
X
Unit Outdoor RV
Sirip
Kompresor
Aluminium
Rotary
Pengatur Refrigeran
Klasifikasi
RV15A
X
X
X
RV20A
X
X
X
RV25A
X
X
X
RV35A
X
X
X
RV50A
X
X
X
RV60A
X
X
X
Pipa Kapiler
Tata Nama
2
Informasi Aplikasi
Informasi Aplikasi Kisaran Operasi Pastikan suhu operasi berada dalam kisaran yang diperbolehkan. Pendinginan Outdoor DB (°C)
Perhatian: : Penggunaan AC diluar jangkauan kerja suhu dan kelembaban dapat mengakibatkan kerusakan serius.
46 43
19
14
3
19
23
Indoor WB (°C)
Informasi Aplikasi
Diagram Sirkuit Refrigeran Model:FTV-A -RV-A
4
Informasi Aplikasi
Panduan Instalasi Perhatian: : Tepian tajam dan permukaan coil merupakan bahaya cedera potensial. Harap Hindari kontak.
Diagram Instalasi Unit Indoor
75mm atau lebih dari atap Panel Depan
50mm atau lebih dari dinding (pada kedua sisi)
Unit outdoor
5
Potong pipa insulasi termal sesuai panjang yang sesuai dan bungkus dengan tape, pastikan tidak ada celah yang tertinggal pada garis potong pipa isolasi Bungkus pipa isolasi dengan tape penyelesaian dari bawah ke atas.
M4 x 12L Filter Udara
Tutup celah pipa dengan dempul
Service Lid „ Membuka service lid Service lid adalah tipe buka/tutup. „ Cara membuka 1) Lepaskan baut pada service lid 2) Tarik service lid ke bawah secara diagonal searah Jarum jam. 3) Turunkan.
Informasi Aplikasi
Pembersihan Outdoor Perhatian Jika unit condensing dioperasikan pada atmosfir yang mengandung minyak (termasuk minyak mesin), garam (daerah pantai), gas sulfida (dekat sumber air panas, lokasi penyulingan minyak), atau zat serupa dapat menyebabkan kerusakan unit. Model: RV15/20/25/35/50/60A Unit outdoor harus dipasang sedemikian rupa, untuk mencegah korsleting dari udara panas atau penyumbatan udara. Silahkan ikuti pembersihan instalasi yang ditunjukkan dalam gambar. Pilih tempat yang paling sejuk dimana suhu udara masuk tidak lebih besar dari suhu udara luar (lihat Kisaran Operasi).
A
D
100
500
100
500
RV35/50/60A
300
1000
300
500
Penghalang H/2
C
Catatan: Jika ada penghalang yang lebih tinggi dari setengah tinggi unit (H), harap berikan lebih banyak ruangan dari gambaran yang ditunjukkan pada tabel di atas..
D
Akses servis
C
Penghalang
B
UdaraBalik
A
Penghalang
Model RV15/20/25A
H Udara Discharge
Jarak minimum, mm Dimensi
Udara Balik
Penghalang
B
Ukuran Kabel Model Ukuran kabel catu daya Jumlah kabel Ukuran kabel sambungan Jumlah kabel Sekring yang direkomendasikan
Unit mm2 mm2 A
FTV15/20/25/35A
FTV50/60A
RV15/20/25/35A 1.5 3 1.5 3
RV50/60A 2.5 3 2.5 3
15
15
6
Informasi Aplikasi
Refrigerant Piping Panjang Pipa dan Ketinggian Jika panjang pipa terlalu panjang, baik kapasitas maupun kehandalan akan turun. Karena jumlah bengkokan bertambah, hambatan pemipaan sistem terhadap aliran refrigern meningkat, sehingga menurunkan kapasitas pendinginan, dan akibatnya kompresor bisa menjadi rusak. Selalu pilih jalur terpendek dan ikuti rekomendasinya seperti ditabulasikan di bawah ini: Unit Indoor
Unit Outdoor
L
E
Model Pendinginan Model
Indoor
Outdoor Panjang minimum yang diperbolehkan (L), m Panjang maksimum yang diperbolehkan (L), m Ketinggian maksimum yang diperbolehkan (E), m Ukuran Pipa Gas, mm/(in) Ukuran Pipa Cair, mm/(in) Model
Indoor
Outdoor Panjang minimum yang diperbolehkan (P), m Panjang maksimum yang diperbolehkan (P), m Ketinggian maksimum yang diperbolehkan (E), m Ukuran Pipa Gas, mm/(in) Ukuran Pipa Cair, mm/(in)
7
FTV15A
FTV20A
FTV25A
FTV35A
RV15A
RV20A
RV25A
RV35A
3 15
15
20
25
8
8
12
15
9.52 / (3/8") 6.35 / (1/4")
9.52 / (3/8") 6.35 / (1/4")
9.52 / (3/8”) 6.35 / (1/4”)
9.52 / (3/8”) 6.35 / (1/4”)
FTV50A
FTV60A
RV50A
RV60A 3 30 15
12.7 / (1/2") 6.35 / (1/4")
12.7 / (1/2”) 6.35 / (1/4")
Informasi Aplikasi
Pengisian Tambahan • Gas refrigeran diisi di unit outdoor dan jika panjang pipa 7.5m, pengisian refrigeran tambahan setelah pemakuman tidak diperlukan. • Jika panjang pipa lebih dari 7.5m, pengisian refrigeran tambahan (g) per panjang 1 m tambahan seperti berikut: Model
Indoor
FTV15/20/25/35/50/60A
Outdoor Pengisian tambahan, g/m
RV15/20/25/35/50/60A 17
Tindakan pencegahan khusus saat menangani unit R32 Model FTV15A-RV15A FTV20A-RV20A FTV25A-RV25A FTV35A-RV35A FTV50A-RV50A FTV60A-RV60A
TambahanR32, kg untuk pipa 7,5m
Tambahan R32, kg untuk Area Lantai Minimum,Xm2 Area Lantai Minimum,Xm 2 Panjang pipa maksmimal (sesuai Panjang pipa maksmimal (pada pipa 7.5m) yang diperbolehkan* yang diperbolehkan**)
0.40 0.45 0.52 0.73 0.75 0.70
Tinggi Instalasi, ho (m) =
0.15 0.19 0.26 0.51 0.54 0.47
0.53 0.58 0.73 1.03 1.13 1.08
0.27 0.32 0.51 1.01 1.22 1.11
1.8
• Pemasangan pipa harus dijaga seminimal mungkin dan pemipaan harus dilindungi dari kerusakan fisik dan tidak dipasang di tempat yang tidak berventilasi; • Konektor mekanik dan sambungan flare yang dapat digunakan kembali disarankan mudah diakses untuk keperluan perawatan.
PERHATIAN Sebelum pemasangan, pastikan resiko pengapian diminimalkan dan hindari bekerja di ruang tertutup. Pastikan ventilasi yang memadai tersedia dengan membuka jendela atau pintu. • Bila sambungan flare digunakan kembali di dalam ruangan, bagian flare harus dibuat ulang. • Hindari pemasangan AC di tempat di mana ada bahaya terkena api terbuka yang beroperasi secara terus-menerus (misalnya pemanas listrik yang beroperasi). • Setiap orang yang terlibat dengan mengerjakan atau membongkar sirkuit refrigeran harus mempunyai sertifikat yang masih berlaku dari otoritas penilaian iterakreditasi, yang memberi wewenang untuk menangani refrigeran secara aman sesuai dengan spesifikasi penilaian industri yang diakui. Memeriksa keberadaan refrigeran
Area harus diperiksa dengan detektor refrigeran yang sesuai sebelum dan selama bekerja, untuk memastikan teknisi mengetahui adanya atmosfir yang berpotensi mudah terbakar. Pastikan peralatan deteksi kebocoran yang digunakan sesuai untuk digunakan dengan refrigeran yang mudah terbakar, yakni tidak memicu, cukup tertutup atau aman secara intrinsik.. Memeriksa keberadaan alat pemadam kebakaran
Jika ada pekerjaan panas yang harus dilakukan pada peralatan pendingin atau komponen terkait, peralatan pemadam kebakaran yang sesuai harus tersedia. Sediakan bubuk kering atau pemadam api CO2 yang dekat dengan area pengisian. Tidak ada sumber pengapian Semua sumber pengapian yang mungkin, termasuk rokok, harus dijaga cukup jauh dari lokasi pemasangan, perbaikan, pemindahan dan pembuangan, dimana zat pendingin yang mudah terbakar dapat menyebar ke ruang sekitarnya. Tanda "Dilarang Merokok" harus dipasang. Pemeriksaan berikut harus diterapkan pada instalasi: - Tanda pada peralatan harus tetap terlihat dan terbaca. Tanda yang tidak terbaca harus dikoreksi; - Pipa atau komponen pendingin dipasang pada posisi di manatidak mungkin terkena zat apapun yang dapat menimbulkan korosi pada komponen yang mengandung refrigeran, kecuali komponen tersebut terbuat dari bahan yang secara inheren tahan terhadap korosi atau terlindungi secara tepat agar tidak berkarat..
8
Informasi Aplikasi
Metode deteksi kebocoran Pastikan detektor bukan sumber penyulut yang potensial (misalnya obor halida) dan cocok untuk refrigeran yang digunakan. Peralatan deteksi kebocoran harus ditetapkan pada persentase LFL refrigeran (untuk R32, LFL adalah 13%) dan harus dikalibrasi ke refrigeran yang digunakan dan persentase gas yang sesuai (maksimum 25%) dikonfirmasi. Cairan pendeteksi kebocoran cocok untuk digunakan dengan kebanyakan refrigeran namun penggunaan deterjen yang mengandung klorin harus dihindari karena klorin dapat bereaksi dengan refrigerant dan menimbulkan korosi pada pipa tembaga. Jika dicurigai ada kebocoran, semua nyala api harus dilepas / padam. Jika kebocoran refrigerant yang memerlukan pematrian ditemukan, semua refrigeran harus dipulihkan dari sistem, atau diisolasi (dengan cara menutup katup) pada bagian sistem yang jauh dari kebocoran. Oxygen free nitrogen (OFN) kemudian dibersihkan menyeluruh pada sistem baik sebelum dan selama proses pemasakan. Pengosongan dan pemindahan Saat membongkar sirkuit pendingin untuk melakukan perbaikan - atau untuk tujuan lain - prosedur konvensional harus digunakan. Namun, penting agar praktik terbaik diikuti karena alasan mudah terbakar merupakan pertimbangan. Prosedur berikut harus dipatuhi: • kosongkan refrigeran; • bersihkan sirkuit dengan gas inert; • pindahkan; • bersihkan lagi dengan gas inert; • buka sirkuit dengan cara memotong atau mematri. Pengisian refrigeran harus diisi ke dalam tabung pengisian yang benar. Sistem akan "membilas" dengan OFN untuk membuat unit aman. Proses ini mungkin perlu diulang beberapa kali. Udara terkompresi atau oksigen tidak boleh digunakan untuk pekerjaan ini. Flushing harus dicapai dengan mengisi kekosongan di sistem dengan OFN dan terus berlanjut sampai tekanan kerja tercapai, kemudian lepaskan ke atmosfer, sampai akhirnya kembali ke posisi kosong. Proses ini harus diulang sampai tidak ada refrigeran yang berada dalam sistem. Bila OFN tambahan terakhir digunakan, sistem harus dibuang ke tekanan atmosfir untuk memungkinkan pekerjaan berlangsung. Operasi ini sangat penting jika operasi brazing pada pekerjaan pipa dilakukan. Pastikan stop kontak untuk pompa vakum tidak dekat dengan sumber pengapian dan tersedia ventilasi. Pelabelan Unit ini sebaiknya diberi label 'penarikan dan pengosongan refrigeran'. Label ini diberi tanggal dan ditandatangani. Pastikan bahwa ada label pada peralatan yang menyatakan bahwa peralatan tersebut mengandung refrigeran yang mudah terbakar. Pemeriksaan keamanan awal meliputi: - Bahwa kapasitor dilepas, ini harus dilakukan dengan cara yang aman untuk menghindari kemungkinan terjadinya percikan; - Tidak akan ada komponen listrik dan kabel listrik yang terpapar saat mengisi, memulihkan atau membersihkan sistem; Memperbaiki komponen yang aman secara intrinsik Jangan gunakan beban induktif atau kapasitansi permanen ke sirkuit tanpa memastikan bahwa hal ini tidak akan melebihi voltase dan arus yang diperbolehkan untuk peralatan yang digunakan. Ganti komponen hanya dengan part yang ditentukan oleh produsen.
9
Data Suara
Data Suara Tingkat Tekanan Suara Model
FTV15A
FTV20A
FTV25A
FTV35A
FTV50A
FTV60A
Kecepat an 125Hz Turbo Cepat Sedang Pelan Senyap Turbo Cepat Sedang Pelan Senyap Turbo Cepat Sedang Pelan Senyap Turbo Cepat Sedang Pelan Senyap Turbo Cepat Sedang Pelan Senyap Turbo Cepat Sedang Pelan Senyap
42 40 34 29 25 42 40 34 29 25 32 30 27 24 23 35 33 31 30 29 23 21 17 14 12 42 40 37 34 31
Tekanan Suara 1/1 Oktaf (dB, ref 20μPa) 250Hz
500Hz
1kHz
2kHz
4kHz
8kHz
36 33 29 24 21 36 33 29 24 21 36 34 31 26 24 37 36 33 28 27 32 31 28 26 25 44 42 39 37 35
37 35 31 25 22 37 35 31 25 22 37 35 32 27 25 37 37 34 29 28 37 36 34 31 31 44 42 39 37 35
34 32 27 21 17 34 32 27 21 17 35 33 28 22 20 36 35 30 24 23 40 38 35 32 31 44 42 39 36 33
32 30 25 18 14 32 30 25 18 14 31 29 23 15 13 33 32 26 19 18 38 36 32 29 27 42 39 36 32 29
23 21 15 12 10 23 21 15 12 10 24 21 14 7 6 25 24 17 11 11 29 27 23 20 20 34 32 27 24 22
10 8 4 5 4 10 8 4 5 4 10 8 6 7 5 13 12 11 10 10 17 15 13 12 13 22 20 19 18 18
Model
Keselur Kriteria uhan Kebisin (dBA) gan 39 33 37 31 32 26 26 NA 23 NA 39 33 37 31 32 26 26 NA 23 NA 39 34 37 32 33 26 27 21 25 NA 40 35 39 34 35 29 29 23 28 22 44 39 42 37 39 34 36 32 35 30 48 44 46 43 43 39 39 35 37 33
Lokasi Pengukuran
FTV15/20/25/35/50/60A 0.8m Mikrofon Standar : JIS C 9612
1.0m
10
Data Suara
Kurva NC
FTV15A
80
NC-70
70
Tingkat Tekanan Suara (dB, ref 20μPa)
NC-65 60
NC-60 NC-55
50
NC-50 NC-45
40
NC-40 NC-35
T
H
M
30
NC-30 NC-25
L Q
20
NC-20
10
0 125
250
500
1000
2000
4000
8000
Frekuensi pita oktaf (Hz)
FTV20A
80
NC-70
Tingkat Tekanan Suara (dB, ref 20μPa)
70
NC-65 60
NC-60 NC-55
50
NC-50 NC-45
40
T
NC-40
M L
NC-30
NC-35
H 30
NC-25
Q
20
NC-20
10
0 125
250
500
1000
Frekuensi pita oktaf (Hz)
11
2000
4000
8000
Data Suara
FTV25A
80
NC-70
70
NC-65
Tingkat Tekanan Suara (dB, ref 20μPa)
60
NC-60 NC-55
50
NC-50 NC-45
40
NC-40
T
NC-35
H M L
30
20
NC-30 NC-25
Q
NC-20
10
0 125
250
500
1000
2000
4000
8000
Frekuensi pita oktaf (Hz)
FTV35A
80
NC-70
70
Tingkat Tekanan Suara (dB, ref 20μPa)
NC-65 60
NC-60 NC-55
50
NC-50 NC-45
40
T
M
30
NC-40
H
NC-35 NC-30
L
NC-25
Q
20
NC-20
10
0 125
250
500
1000
2000
4000
8000
Frekuensi pita oktaf (Hz)
12
Data Suara
FTV50A
80
NC-70
70
NC-65
Tingkat Tekanan Suara (dB, ref 20μPa)
60
NC-60 NC-55
50
NC-50 NC-45
T
40
M
H
Q
30
NC-40 NC-35
L
NC-30 NC-25
20
NC-20
10
0 125
250
500
1000
2000
4000
8000
Frekuensi pita oktaf (Hz)
FTV60A
80
NC-70
70
Tingkat Tekanan Suara (dB, ref 20μPa)
NC-65 60
NC-60 NC-55
50
NC-50
T H L
40
30
NC-45
M
NC-40
Q
NC-35 NC-30 NC-25
20
NC-20
10
0 125
250
500
1000
Frekuensi pita oktaf (Hz)
13
2000
4000
8000
Data Fisik & Engineering
Data Fisik & Engineering Data Engineering - R32 MODEL (Pendinginan) MODEL
UNIT INDOOR UNIT OUTDOOR
KAPASITAS PENDINGINAN NOMINAL TOTAL DAYA INPUT (PENDINGINAN) NOMINAL ARUS NOMINAL (PENDINGINAN) (MAKS – MIN) EER TAMBAHAN REFRIGERAN CATU DAYA TIPE REFRIGERAN KONTROL
Btu/h W W A W/W kg V/Ph/Hz
UDARA DISCHARGE
UNIT INDOOR
OPERATION TURBO CEPAT AIR FLOW SEDANG PELAN SENYAP TINGKAT TEKANAN SUARA (T/H/M/L/Q) DIMENSI UNIT PANJANG X LEBAR X TINGGI DIMENSI PACKING PANJANG X LEBAR X TINGGI BERAT UNIT UKURAN PIPA DRAIN TIPE FAN PENGGERAK TIPE INDEX OF PROTECTION (IP) GRADE INSULASI FAN MOTOR BESARAN DAYA INPUT BESARAN ARUS OUTPUT MOTOR KUTUB MATERIAL PIPA DIAMETER COIL MATERIAL SIRIP AREA DEPAN BARIS TIPE AIR QUALITY FILTER JUMLAH CASING ALIRAN UDARA TINGKAT TEKANAN SUARA DIMENSI UNIT PANJANG X LEBAR X TINGGI DIMENSI PACKING BERAT UNIT KONEKSI PIPA
UNIT OUTDOOR
FAN
FAN MOTOR
KOMPRESOR
COIL
CASING
W A W
mm m2
pc COLOUR l/s / CFM dBA mm mm kg
FTV20A FTV25A RV20A RV25A 7000 9000 2050 2640 580 780 2.85 3.63 3.53 3.38 0.45 0.52 220-240/1/50 220-240/1/50 R32 R32 SIRIP OTOMATIS(ATAS & BAWAH) & MANUAL (KIRI & KANAN) REMOTE KONTROL WIRELESS 160/338 160/338 169/358 155/328 155/328 161/342 126/266 126/266 133/282 98/208 98/208 106/225 90/191 90/191 99/209 39/37/32/26/23 39/37/32/26/23 39/37/33/27/25 288 X 800 X 206 288 X 800 X 206 288 X 800 X 206 344 X 874 X 274 344 X 874 X 274 344 X 874 X 274 7.5 7.5 9.0 19.05 19.05 19.05 CROSS FLOW FAN LANGSUNG SILICON CONTROLLED RECTIFIER IP20 KELAS E 34 34 37 0.19 0.19 0.19 18 18 18 4 4 4 TEMBAGA 7 7 7 ALUMINIUM 0.18 0.18 0.18 1 1 2 SARANET SARANET SARANET 2 2 2 WHITE 255/540 304/644 304/644 46 46 46 485 X 566 X 256 485 X 566 X 256 485 X 566 X 256 532X668X366 532X668X366 532X668X366 19 19.5 21
TYPE CAIR GAS TANPA PENGISIAN MAKSIMUM TIPE PENGGERAK TIPE INDEX OF PROTECTION (IP) GRADE INSULASI BESARAN DAYA INPUT BESARAN ARUS OUTPUT MOTOR KUTUB TIPE TIPE TIPE OLI JUMLAH OLI BESARAN DAYA INPUT BESARAN ARUS LOCKED ROTOR AMP. MATERIAL PIPA DIAMETER MATERIAL SIRIP AREA DEPAN BARIS SIZE
PANJANG PIPA
l/s / CFM l/s / CFM l/s / CFM l/s / CFM l/s / CFM dBA mm mm kg mm
FTV15A RV15A 5000 1470 380 1.80 3.87 0.40 220-240/1/50
mm mm m m
6.35 9.52 7.5 15
B 36 0.17 15 6
cm3 W A A
RM-LP56EG 230 310 1.44 8.0
mm
7
m2
0.19 1
WARNA
FLARE VALVE 6.35 9.52 7.5 15 BALING-BALING LANGSUNG SPLIT KAPASITOR PERMANEN IP44 B 35 0.16 15 6 ROTARY FW68DA 210 511 2.50 18.0 TEMBAGA 7 ALUMINIUM 0.28 1 PUTIH GADING
6.35 9.52 7.5 20
B 35 0.16 15 6 RM-LP56EG 240 708 3.28 16.0 7 0.28 1
SEMUA UNIT TELAH DI TES DAN MEMENUHI ISO 5151 (UNIT NON-DUCTED) ATAU ISO 13253 (UNIT DUCTED). PENDINGINAN INDOOR: 27°C DB / 19°C WB OUTDOOR: 35°C DB / 24°C WB
14
Data Fisik & Engineering
Engineering Data – MODEL R32 MODEL (Pendinginan) MODEL
UNIT INDOOR UNIT OUTDOOR
KAPASITAS PENDINGINAN NOMINAL TOTAL DAYA INPUT (PENDINGINAN) NOMINAL ARUS NOMINAL (PENDINGINAN) (MAKS – MIN) EER TAMBAHAN REFRIGERAN CATU DAYA TIPE REFRIGERAN KONTROL
Btu/h W W A W/W kg V/Ph/Hz
UDARA DISCHARGE OPERASI
TURBO CEPAT SEDANG PELAN SENYAP TINGKAT TEKANAN SUARA (T/H/M/L/Q) DIMENSI UNIT PANJANG X LEBAR X TINGGI DIMENSI PACKING PANJANG X LEBAR X TINGGI BERAT UNIT UKURAN PIPA DRAIN TIPE FAN PENGGERAK TIPE INDEX OF PROTECTION (IP) GRADE INSULASI FAN MOTOR BESARAN DAYA INPUT BESARAN ARUS OUTPUT MOTOR KUTUB MATERIAL PIPA DIAMETER COIL MATERIAL SIRIP AREA DEPAN BARIS TIPE KUALITAS FILTER UDARA JUMLAH CASING ALIRAN UDARA TINGKAT TEKANAN SUARA DIMENSI UNIT PANJANG X LEBAR X TINGGI DIMENSI PACKING PANJANG X LEBAR X TINGGI BERAT UNIT
UNIT INDOOR
ALIRAN UDARA
KONEKSI PIPA
UNIT OUTDOOR
FAN
FAN MOTOR
KOMPRESOR
COIL
W A W
mm m2
pc WARNA l/s / CFM
FTV50A RV50A 18000 5280 1730 7.96 3.05 0.75 220-240/1/50 R32 SIRIP OTOMATIS (ATAS & BAWAH) & MANUAL (KIRI & KANAN) WIRELESS REMOTE CONTROL 176/372 280/594 168/355 251/531 141/298 224/474 114/242 199/422 106/225 180/381 40/39/35/29/28 44/42/39/36/35 288 X 800 X 206 310 X 1065 X 224 344 X 874 X 274 386 X 1136 X 314 9.0 14.0 19.05 19.05 CROSS FLOW FAN LANGSUNG SILICON CONTROLLED RECTIFIER IP20 KELAS E 42 61 0.21 0.30 18 26 4 4 TEMBAGA 7 7 ALUMINIUM 0.18 0.29 2 2 SARANET SARANET 2 2 PUTIH 827 1430
dBA mm mm kg
48 550 X 658 X 273 580 x 775 x 335 28
mm mm m m
6.35 9.52 7.5 25
W A W
B 51 0.23 20 6
51 651 X 855 X 328 693 X 990 X 415 41
TIPE CAIR GAS TANPA PENGISIAN MAKSIMUM TIPE PENGGERAK TIPE INDEX OF PROTECTION (IP) GRADE INSULASI BESARAN DAYA INPUT BESARAN ARUS MOTOR OUTPUT KUTUB TIPE TIPE OLI JUMLAH OLI BESARAN DAYA INPUT BESARAN ARUS LOCKED ROTOR AMP. MATERIAL PIPA DIAMETER MATERIAL SIRIP AREA DEPAN BARIS UKURAN
PANJANG PIPA
l/s / CFM l/s / CFM l/s / CFM l/s / CFM l/s / CFM dBA mm mm kg mm
FTV35A RV35A 12000 3520 1080 5.10 3.26 0.73 220-240/1/50 R32
CASING
cm3 W A A
FLARE VALVE 6.35 12.7 7.5 30 BALING-BALING LANGSUNG SPLIT CAPACITOR PERMANEN IP23 F 79 0.35 32 6 ROTARY FW50S 670 1590 7.31 34.0
FW50S 350 987 4.66 24.0 TEMBAGA
mm m2
7 ALUMINIUM 0.32 2
WARNA
SEMUA UNIT TELAH DI TES DAN MEMENUHI ISO 5151 (UNIT NON-DUCTED) ATAU ISO 13253 (UNIT DUCTED).
PENDINGINAN INDOOR: 27°C DB / 19°C WB OUTDOOR: 35°C DB / 24°C WB
15
7 ALUMINIUM 0.51 1 PUTIH GADING
FTV60A RV60A 22000 6450 1950 8.99 3.31 0.70 220-240/1/50 R32
303/641 290/614 253/537 224/474 197/418 48/46/43/39/37 310 X 1065 X 224 386 X 1136 X 314 14.0 19.05
72 0.34 30 4 7 0.29 2 SARANET 2 1590 52 651 X 855 X 328 693 X 990 X 415 41 6.35 12.7 7.5 30
F 123 0.54 60 6 FW50S 670 1755 8.11 32.0 ALUMINIUM NA ALUMINIUM 0.51 1
Data Performa
Data Performa Langkah Perhitungan Metode interpolasi dapat digunakan untuk mendapatkan kapasitas total cooling (TC), dan kapasitas sensible cooling (SC), dan power input (PI), pada suhu yang tidak tercantum dalam tabel. Metode ekstrapolasi tidak diperkenankan untuk digunakan. Contoh: AFR (CFM) EWB
16°C
195
19°C
22°C
EDB 21°C 24°C 27°C 30°C 24°C 27°C 30°C 33°C 27°C 30°C 33°C 36°C
TC 2.02 2.02 2.04 2.10 2.23 2.23 2.23 2.26 2.45 2.45 2.45 2.46
19°C SC 1.54 1.84 2.04 2.10 1.44 1.64 2.03 2.26 1.41 1.71 2.00 2.27
PI 0.49 0.49 0.49 0.50 0.50 0.50 0.50 0.50 0.51 0.51 0.51 0.51
TC 1.95 1.95 1.97 2.04 2.15 2.15 2.15 2.18 2.36 2.36 2.37 2.38
25°C SC 1.50 1.80 1.97 2.04 1.40 1.61 1.99 2.18 1.37 1.68 1.96 2.22
PI 0.53 0.53 0.54 0.54 0.54 0.54 0.54 0.54 0.55 0.55 0.55 0.55
TC 1.87 1.88 1.90 1.98 2.07 2.07 2.08 2.11 2.28 2.28 2.28 2.29
Suhu Outdoor 30°C 35°C SC PI TC SC 1.46 0.58 1.80 1.42 1.76 0.58 1.80 1.71 1.90 0.58 1.83 1.83 1.98 0.58 1.91 1.91 1.36 0.59 1.99 1.32 1.57 0.59 1.99 1.53 1.94 0.59 2.00 1.89 2.11 0.59 2.04 2.04 1.34 0.60 2.19 1.30 1.64 0.60 2.19 1.60 1.92 0.60 2.19 1.88 2.18 0.60 2.21 2.13
PI 0.63 0.63 0.63 0.63 0.64 0.64 0.64 0.64 0.65 0.65 0.65 0.65
TC 1.65 1.66 1.69 1.77 1.83 1.83 1.84 1.89 2.01 2.01 2.02 2.04
40°C SC 1.32 1.60 1.69 1.77 1.23 1.43 1.77 1.89 1.21 1.50 1.77 2.00
PI 0.68 0.68 0.68 0.69 0.69 0.69 0.69 0.70 0.71 0.71 0.71 0.71
TC 1.52 1.53 1.57 1.66 1.69 1.69 1.71 1.77 1.86 1.86 1.87 1.90
46°C SC 1.24 1.51 1.57 1.66 1.16 1.36 1.68 1.77 1.14 1.42 1.68 1.89
PI 0.75 0.75 0.75 0.76 0.76 0.76 0.76 0.77 0.78 0.78 0.78 0.78
Solusi: Berdasarkan Tabel Performa, 1. Lihat kolom Indoor DB, - 25°C terletak antara 24°C & 27°C untuk WB 16°C. - 25°C terletak antara 24°C & 27°C untuk WB 19°C.. - Dengan demikian, Interpolasi perlu diterapkan. 2. Lihat kolom Indoor WB, - 17°C terletak antara 16°C & 19°C untuk 25°C DB. - Dengan demikian, Interpolasi perlu diterapkan. 3. Lihat kolom Outdoor DB, - 37°C terletak antara 35°C & 40°C. - Dengan demikian, Interpolasi perlu diterapkan. Langkah Pertama Interpolasi Indoor WB Cari TC, SC & PI (a) Indoor: 25°C DB, 16°C WB Outdoor: 35°C DB (b) Indoor: 25°C DB, 19°C WB Outdoor: 35°C DB (c) Indoor: 25°C DB, 16°C WB Outdoor: 40°C DB (d) Indoor: 25°C DB, 19°C WB Outdoor: 40°C DB
Langkah Kedua Interpolasi Indoor DB Cari TC, SC & PI (a) Indoor: 25°C DB, 17°C WB Outdoor: 35°C DB (b) Indoor: 25°C DB, 17°C WB Outdoor: 40°C DB
Langkah Ketiga Interpolation Outdoor DB Cari TC, SC & PI (a) Indoor: 25°C DB, 17°C WB Outdoor: 37°C DB
16
Data Performa
Detail Kalkulasi:
Dengan Metode Interpolasi 25°C – 24°C
Langkah Pertama:
27°C – 24°C
Dapatkan TC, SC & PI untuk
x1 = 1.81kW
(a) Kondisi Indoor: 25°C DB, 16°C WB Kondisi Outdoor: 35°C DB
Demikian juga,
16
EDB TC
SC
PI
24
1.80
25
x1
1.71 y1
0.63 z1
27
1.83
1.83
0.63 Dengan Metode Interpolasi 25°C – 24°C 27°C – 24°C
Suhu Outdoor
19
35°C
EDB
1.83kW – 1.80kW
z1 = 0.63kW
35°C
(b) Kondisi Indoor: 25°C DB, 19°C WB Kondisi Outdoor: 35°C DB
EWB
x1 – 1.80kW
y1 = 1.75kW
Suhu Outdoor EWB
=
=
x2 – 1.99kW 1.99kW – 1.99kW
x2 = 1.99kW
TC
SC
PI
24
1.99
25
x2
1.32 y2
0.64 z2
27
1.99
1.53
0.64
Ulangi proses yang sama untuk (c) & (d) pada langkah pertama
Demikian juga, y2 = 1.39kW z2 = 0.64kW
(d) x4 = 1.83 W; y4 = 1.30 kW; z4 = 0.69 kW
(c) x3 = 1.69 kW; y3 = 1.63 kW; z3 = 0.68 kW Langkah Kedua:
Dengan Metode Interpolasi
Dapatkan TC, SC & PI untuk
17°C – 16°C
(a) Kondisi Indoor: 25°C DB, 17°C WB Kondisi Outdoor: 35°C DB
19°C – 16°C x5 = 1.87kW
Suhu Outdoor EWB
EDB
16 17 19
25
35°C TC
SC
PI
1.81 x5
1.75
0.63
y5
z5
1.99
1.39
0.64
Ulangi proses yang sama untuk (b) pada Langkah Kedua (b) x6 = 1.74 kW; y6 = 1.52 kW; z6 = 0.68 kW
17
Demikian juga, y5 = 1.63kW z5 =0.63kW
=
x5 – 1.81kW 1.99kW – 1.81kW
Data Performa
Langkah Ketiga: Dapatkan TC, SC & PI untuk (a) Kondisi Indoor: 25°C DB, 17°C WB Kondisi Outdoor: 37°C DB Suhu Outdoor EWB
EDB
25
17
35°C
37°C
40°C
TC
SC
PI
TC
SC
PI
TC
SC
PI
1.87
1.63
0.63
x
y
z
1.74
1.52
0.68
Dengan Metode Interpolasi 37°C – 35°C x – 1.87kW 40°C – 35°C = 1.74kW – 1.87kW
Demikian juga, y = 1.59kW z = 0.65kW
x = 1.82kW
18
Data Performa
Tabel Performa Model: FTV15A - RV15A Mode Pendinginan "AFR (CFM)" EWB EDB
16°C
208
19°C
22°C
16°C
266
19°C
22°C
16°C
328
19°C
22°C
21°C 24°C 27°C 30°C 24°C 27°C 30°C 33°C 27°C 30°C 33°C 36°C 21°C 24°C 27°C 30°C 24°C 27°C 30°C 33°C 27°C 30°C 33°C 36°C 21°C 24°C 27°C 30°C 24°C 27°C 30°C 33°C 27°C 30°C 33°C 36°C
TC 1.39 1.39 1.40 1.44 1.53 1.53 1.53 1.55 1.68 1.68 1.68 1.69 1.44 1.45 1.46 1.52 1.59 1.59 1.60 1.63 1.75 1.75 1.75 1.76 1.50 1.50 1.53 1.60 1.65 1.65 1.66 1.70 1.81 1.81 1.82 1.83
19°C SHC 1.31 1.39 1.40 1.44 1.22 1.40 1.53 1.55 1.19 1.46 1.68 1.69 1.36 1.45 1.46 1.52 1.29 1.49 1.60 1.63 1.26 1.55 1.75 1.76 1.42 1.50 1.53 1.60 1.36 1.58 1.66 1.70 1.34 1.65 1.82 1.83
PI 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.30 0.30 0.30 0.30 0.29 0.29 0.29 0.29 0.30 0.30 0.30 0.30 0.30 0.30 0.30 0.30 0.29 0.29 0.29 0.30 0.30 0.30 0.30 0.30 0.30 0.30 0.30 0.31
TC 1.34 1.34 1.35 1.40 1.47 1.48 1.48 1.50 1.62 1.62 1.62 1.63 1.39 1.39 1.41 1.48 1.53 1.53 1.54 1.58 1.68 1.69 1.69 1.70 1.44 1.45 1.48 1.56 1.59 1.59 1.61 1.65 1.74 1.75 1.75 1.78
25°C SHC 1.27 1.34 1.35 1.40 1.19 1.36 1.48 1.50 1.17 1.42 1.62 1.63 1.33 1.39 1.41 1.48 1.26 1.45 1.54 1.58 1.23 1.52 1.69 1.70 1.39 1.45 1.48 1.56 1.33 1.54 1.61 1.65 1.31 1.61 1.75 1.78
PI 0.31 0.31 0.31 0.31 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.33 0.33 0.33 0.33 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.33 0.33 0.33 0.33 0.33
TC 1.29 1.29 1.30 1.36 1.42 1.42 1.43 1.45 1.56 1.56 1.57 1.58 1.34 1.34 1.37 1.44 1.47 1.48 1.49 1.53 1.62 1.62 1.63 1.65 1.39 1.39 1.43 1.51 1.53 1.53 1.55 1.60 1.68 1.68 1.69 1.71
Suhu Outdoor 30°C 35°C SHC PI TC SHC PI 1.24 0.34 1.24 1.20 0.37 1.29 0.34 1.24 1.24 0.37 1.30 0.34 1.26 1.26 0.37 1.36 0.34 1.31 1.31 0.37 1.16 0.34 1.36 1.12 0.37 1.33 0.34 1.37 1.30 0.37 1.43 0.34 1.37 1.37 0.37 1.45 0.35 1.40 1.40 0.37 1.14 0.35 1.50 1.10 0.38 1.39 0.35 1.50 1.36 0.38 1.57 0.35 1.50 1.50 0.38 1.58 0.35 1.52 1.52 0.38 1.29 0.34 1.28 1.26 0.37 1.34 0.34 1.29 1.29 0.37 1.37 0.34 1.32 1.32 0.37 1.44 0.35 1.39 1.39 0.38 1.22 0.35 1.42 1.19 0.38 1.42 0.35 1.42 1.39 0.38 1.49 0.35 1.43 1.43 0.38 1.53 0.35 1.48 1.48 0.38 1.20 0.35 1.56 1.17 0.38 1.48 0.35 1.56 1.45 0.38 1.63 0.35 1.56 1.56 0.38 1.65 0.36 1.59 1.59 0.39 1.35 0.34 1.33 1.31 0.37 1.39 0.34 1.34 1.34 0.37 1.43 0.35 1.38 1.38 0.38 1.51 0.35 1.46 1.46 0.38 1.30 0.35 1.46 1.26 0.38 1.51 0.35 1.47 1.47 0.38 1.55 0.35 1.49 1.49 0.38 1.60 0.35 1.55 1.55 0.38 1.27 0.36 1.61 1.24 0.39 1.58 0.36 1.61 1.54 0.39 1.69 0.36 1.62 1.62 0.39 1.71 0.36 1.65 1.65 0.39
Keterangan: AFR: Air flow rate (CFM) EWB: Entering Wet Bulb Temp. (°C) EDB: Entering Dry Bulb Temp. (°C) TC: Kapasitas Total Cooling (kW) SC: Kapasitas Sensible Cooling (kW) PI: Power Input (kW) Catatan: 1. Rating yang ditunjukkan adalah kapasitas bersih.. 2. menunjukkan kapasitas nominal. 3. Interpolasi langsung diperbolehkan. Jangan ekstrapolasi. 4. Unit dapat beroperasi pada ambient sekitar 19°C sampai 46°C DB (pendinginan) tanpa kesalahan tekanan.
19
40°C TC SHC PI 1.13 1.12 0.40 1.14 1.14 0.40 1.16 1.16 0.40 1.22 1.22 0.40 1.25 1.05 0.40 1.26 1.22 0.40 1.26 1.26 0.41 1.30 1.30 0.41 1.38 1.03 0.41 1.38 1.27 0.41 1.38 1.38 0.41 1.40 1.40 0.41 1.18 1.17 0.40 1.18 1.18 0.40 1.22 1.22 0.40 1.29 1.29 0.41 1.30 1.11 0.41 1.30 1.30 0.41 1.32 1.32 0.41 1.37 1.37 0.41 1.43 1.09 0.42 1.43 1.36 0.42 1.44 1.44 0.42 1.46 1.46 0.42 1.22 1.22 0.40 1.23 1.23 0.41 1.27 1.27 0.41 1.35 1.35 0.41 1.34 1.18 0.41 1.35 1.35 0.41 1.37 1.37 0.41 1.43 1.43 0.42 1.48 1.16 0.42 1.48 1.45 0.42 1.49 1.49 0.42 1.53 1.53 0.42
46°C TC SHC PI 1.05 1.05 0.44 1.05 1.05 0.44 1.08 1.08 0.44 1.14 1.14 0.44 1.16 0.99 0.45 1.16 1.15 0.45 1.17 1.17 0.45 1.21 1.21 0.45 1.28 0.97 0.45 1.28 1.21 0.45 1.28 1.28 0.45 1.30 1.30 0.46 1.09 1.09 0.44 1.09 1.09 0.44 1.13 1.13 0.45 1.20 1.20 0.45 1.20 1.05 0.45 1.20 1.20 0.45 1.22 1.22 0.45 1.28 1.28 0.46 1.32 1.03 0.46 1.33 1.29 0.46 1.33 1.33 0.46 1.36 1.36 0.46 1.12 1.12 0.45 1.14 1.14 0.45 1.19 1.19 0.45 1.26 1.26 0.46 1.24 1.11 0.45 1.25 1.25 0.45 1.27 1.27 0.46 1.34 1.34 0.46 1.37 1.09 0.46 1.37 1.37 0.46 1.38 1.38 0.46 1.42 1.42 0.47
Data Performa
Tabel Performa Model: FTV20A - RV20A Mode Pendinginan AFR (CFM) EWB
16°C
208
19°C
22°C
16°C
266
19°C
22°C
16°C
328
19°C
22°C
EDB 21°C 24°C 27°C 30°C 24°C 27°C 30°C 33°C 27°C 30°C 33°C 36°C 21°C 24°C 27°C 30°C 24°C 27°C 30°C 33°C 27°C 30°C 33°C 36°C 21°C 24°C 27°C 30°C 24°C 27°C 30°C 33°C 27°C 30°C 33°C 36°C
TC 1.93 1.94 1.95 2.01 2.13 2.13 2.14 2.16 2.35 2.35 2.35 2.35 2.01 2.02 2.04 2.13 2.22 2.22 2.23 2.27 2.43 2.44 2.44 2.46 2.09 2.10 2.13 2.24 2.30 2.30 2.32 2.37 2.52 2.52 2.53 2.56
19°C SC 1.64 1.94 1.95 2.01 1.53 1.75 2.14 2.16 1.50 1.83 2.13 2.35 1.71 2.02 2.04 2.13 1.62 1.87 2.23 2.27 1.59 1.95 2.28 2.46 1.79 2.10 2.13 2.24 1.71 1.98 2.32 2.37 1.68 2.07 2.42 2.56
PI 0.44 0.44 0.44 0.44 0.45 0.45 0.45 0.45 0.46 0.46 0.46 0.46 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.46 0.46 0.46 0.46 0.45 0.45 0.45 0.45 0.46 0.46 0.46 0.46 0.46 0.46 0.47 0.47
TC 1.86 1.87 1.89 1.95 2.06 2.06 2.06 2.09 2.26 2.26 2.27 2.28 1.94 1.94 1.97 2.07 2.14 2.14 2.15 2.20 2.35 2.35 2.36 2.38 2.01 2.02 2.06 2.17 2.21 2.22 2.24 2.30 2.43 2.43 2.45 2.48
25°C SC 1.60 1.87 1.89 1.95 1.49 1.71 2.06 2.09 1.46 1.79 2.09 2.28 1.67 1.94 1.97 2.07 1.58 1.82 2.15 2.20 1.55 1.91 2.24 2.38 1.74 2.02 2.06 2.17 1.67 1.94 2.24 2.30 1.64 2.03 2.38 2.48
PI 0.48 0.48 0.48 0.48 0.49 0.49 0.49 0.49 0.49 0.49 0.49 0.49 0.48 0.48 0.48 0.49 0.49 0.49 0.49 0.49 0.50 0.50 0.50 0.50 0.49 0.49 0.49 0.49 0.49 0.49 0.50 0.50 0.50 0.50 0.50 0.51
TC 1.80 1.80 1.82 1.89 1.98 1.98 1.99 2.02 2.18 2.18 2.18 2.20 1.87 1.87 1.91 2.00 2.06 2.06 2.08 2.13 2.26 2.26 2.27 2.29 1.93 1.94 1.99 2.11 2.13 2.14 2.16 2.23 2.34 2.34 2.36 2.39
Suhu Outdoor 30°C SC PI TC 1.55 0.52 1.72 1.80 0.52 1.73 1.82 0.52 1.75 1.89 0.52 1.83 1.45 0.53 1.90 1.67 0.53 1.90 1.99 0.53 1.91 2.02 0.53 1.95 1.43 0.54 2.10 1.75 0.54 2.10 2.05 0.54 2.10 2.20 0.54 2.12 1.62 0.52 1.79 1.87 0.52 1.80 1.91 0.52 1.84 2.00 0.53 1.94 1.54 0.53 1.97 1.78 0.53 1.98 2.08 0.53 2.00 2.13 0.53 2.06 1.51 0.54 2.17 1.86 0.54 2.17 2.19 0.54 2.18 2.29 0.54 2.21 1.70 0.53 1.85 1.94 0.53 1.87 1.99 0.53 1.92 2.11 0.53 2.04 1.63 0.53 2.04 1.89 0.54 2.05 2.16 0.54 2.08 2.23 0.54 2.16 1.60 0.55 2.24 1.98 0.55 2.25 2.33 0.55 2.26 2.39 0.55 2.30
35°C SC 1.51 1.73 1.75 1.83 1.41 1.63 1.91 1.95 1.39 1.71 2.01 2.12 1.58 1.80 1.84 1.94 1.50 1.74 2.00 2.06 1.47 1.82 2.14 2.21 1.65 1.87 1.92 2.04 1.58 1.85 2.08 2.16 1.56 1.94 2.26 2.30
PI 0.56 0.56 0.56 0.57 0.57 0.57 0.57 0.57 0.58 0.58 0.58 0.58 0.57 0.57 0.57 0.57 0.58 0.58 0.58 0.58 0.59 0.59 0.59 0.59 0.57 0.57 0.57 0.58 0.58 0.58 0.58 0.59 0.59 0.59 0.59 0.60
TC 1.58 1.59 1.62 1.70 1.75 1.75 1.76 1.81 1.93 1.93 1.93 1.95 1.64 1.65 1.70 1.80 1.81 1.82 1.84 1.91 2.00 2.00 2.01 2.04 1.70 1.71 1.77 1.89 1.87 1.88 1.91 2.00 2.06 2.07 2.08 2.13
40°C SC 1.41 1.59 1.62 1.70 1.32 1.53 1.76 1.81 1.29 1.60 1.89 1.95 1.47 1.65 1.70 1.80 1.39 1.63 1.84 1.91 1.37 1.70 2.01 2.04 1.53 1.71 1.77 1.89 1.48 1.73 1.91 2.00 1.45 1.81 2.08 2.13
PI 0.61 0.61 0.61 0.61 0.62 0.62 0.62 0.62 0.63 0.63 0.63 0.63 0.61 0.61 0.62 0.62 0.62 0.62 0.63 0.63 0.64 0.64 0.64 0.64 0.62 0.62 0.62 0.63 0.63 0.63 0.63 0.64 0.64 0.64 0.64 0.65
TC 1.46 1.47 1.50 1.59 1.62 1.62 1.64 1.69 1.78 1.79 1.79 1.82 1.51 1.53 1.58 1.68 1.67 1.68 1.71 1.78 1.85 1.85 1.86 1.90 1.57 1.58 1.65 1.76 1.73 1.74 1.78 1.87 1.91 1.91 1.93 1.99
46°C SC 1.32 1.47 1.50 1.59 1.24 1.45 1.64 1.69 1.22 1.51 1.79 1.82 1.38 1.53 1.58 1.68 1.31 1.54 1.71 1.78 1.29 1.62 1.86 1.90 1.44 1.58 1.65 1.76 1.39 1.63 1.78 1.87 1.37 1.72 1.93 1.99
PI 0.67 0.67 0.67 0.68 0.68 0.68 0.68 0.69 0.69 0.69 0.69 0.70 0.68 0.68 0.68 0.69 0.69 0.69 0.69 0.70 0.70 0.70 0.70 0.71 0.68 0.68 0.69 0.70 0.69 0.69 0.70 0.70 0.71 0.71 0.71 0.71
Keterangan: AFR: Air flow rate (CFM) EWB: Entering Wet Bulb Temp. (°C) EDB: Entering Dry Bulb Temp. (°C) TC: Kapasitas Total Cooling (kW) SC: Kapasitas Sensible Cooling (kW) PI: Power Input (kW) Catatan: 1. Rating yang ditunjukkan adalah kapasitas bersih.. 2. menunjukkan kapasitas nominal. 3. Interpolasi langsung diperbolehkan. Jangan ekstrapolasi. 4. Unit dapat beroperasi pada ambient sekitar 19°C sampai 46°C DB (pendinginan) tanpa kesalahan tekanan.
20
Data Performa
Model: FTV25A - RV25A Mode Pendinginan AFR (CFM) EWB
16°C
225
19°C
22°C
16°C
282
19°C
22°C
16°C
342
19°C
22°C
EDB 21°C 24°C 27°C 30°C 24°C 27°C 30°C 33°C 27°C 30°C 33°C 36°C 21°C 24°C 27°C 30°C 24°C 27°C 30°C 33°C 27°C 30°C 33°C 36°C 21°C 24°C 27°C 30°C 24°C 27°C 30°C 33°C 27°C 30°C 33°C 36°C
TC 2.49 2.49 2.51 2.59 2.75 2.75 2.75 2.78 3.02 3.02 3.02 3.03 2.59 2.60 2.63 2.74 2.85 2.86 2.87 2.92 3.14 3.14 3.14 3.16 2.69 2.70 2.74 2.88 2.96 2.97 2.99 3.05 3.24 3.25 3.26 3.29
19°C SC 2.14 2.49 2.51 2.59 1.99 2.28 2.75 2.78 1.95 2.38 2.78 3.03 2.23 2.60 2.63 2.74 2.11 2.43 2.87 2.92 2.06 2.53 2.97 3.16 2.33 2.70 2.74 2.88 2.23 2.58 2.99 3.05 2.18 2.69 3.15 3.29
PI 0.59 0.59 0.59 0.60 0.60 0.60 0.60 0.60 0.61 0.61 0.61 0.61 0.60 0.60 0.60 0.60 0.61 0.61 0.61 0.61 0.62 0.62 0.62 0.62 0.60 0.60 0.61 0.61 0.61 0.61 0.61 0.62 0.62 0.63 0.63 0.63
TC 2.40 2.40 2.43 2.51 2.65 2.65 2.66 2.69 2.92 2.92 2.92 2.93 2.50 2.50 2.54 2.66 2.75 2.76 2.77 2.83 3.02 3.03 3.04 3.06 2.59 2.60 2.65 2.80 2.85 2.86 2.88 2.97 3.13 3.14 3.15 3.19
25°C SC 2.08 2.40 2.43 2.51 1.94 2.23 2.66 2.69 1.90 2.33 2.73 2.93 2.17 2.50 2.54 2.66 2.06 2.37 2.77 2.83 2.02 2.48 2.91 3.06 2.27 2.60 2.65 2.80 2.18 2.52 2.88 2.97 2.13 2.64 3.10 3.19
PI 0.64 0.64 0.64 0.65 0.65 0.65 0.65 0.65 0.66 0.66 0.66 0.67 0.65 0.65 0.65 0.65 0.66 0.66 0.66 0.66 0.67 0.67 0.67 0.67 0.65 0.65 0.66 0.66 0.66 0.66 0.67 0.67 0.68 0.68 0.68 0.68
TC 2.31 2.31 2.34 2.44 2.55 2.55 2.56 2.61 2.81 2.81 2.81 2.83 2.40 2.41 2.45 2.58 2.65 2.65 2.67 2.74 2.91 2.92 2.92 2.96 2.49 2.50 2.56 2.71 2.74 2.75 2.78 2.87 3.01 3.02 3.03 3.08
Suhu Outdoor 30°C SC PI TC 2.02 0.69 2.22 2.31 0.69 2.22 2.34 0.70 2.25 2.44 0.70 2.36 1.89 0.71 2.45 2.18 0.71 2.45 2.56 0.71 2.47 2.61 0.71 2.52 1.86 0.72 2.70 2.28 0.72 2.70 2.67 0.72 2.70 2.83 0.72 2.73 2.11 0.70 2.30 2.41 0.70 2.31 2.45 0.70 2.37 2.58 0.71 2.49 2.00 0.71 2.54 2.32 0.71 2.55 2.67 0.71 2.57 2.74 0.72 2.65 1.97 0.73 2.80 2.43 0.73 2.80 2.85 0.73 2.81 2.96 0.73 2.85 2.21 0.71 2.39 2.50 0.71 2.40 2.56 0.71 2.47 2.71 0.72 2.62 2.12 0.72 2.63 2.46 0.72 2.64 2.78 0.72 2.67 2.87 0.73 2.78 2.08 0.73 2.89 2.58 0.73 2.90 3.03 0.74 2.91 3.08 0.74 2.97
35°C SC 1.97 2.22 2.25 2.36 1.84 2.13 2.47 2.52 1.81 2.22 2.62 2.73 2.05 2.31 2.37 2.49 1.95 2.27 2.57 2.65 1.91 2.37 2.79 2.85 2.15 2.40 2.47 2.62 2.06 2.40 2.67 2.78 2.03 2.52 2.91 2.97
PI 0.75 0.75 0.76 0.76 0.77 0.77 0.77 0.77 0.78 0.78 0.78 0.78 0.76 0.76 0.76 0.77 0.77 0.77 0.78 0.78 0.79 0.79 0.79 0.79 0.77 0.77 0.77 0.78 0.78 0.78 0.78 0.79 0.80 0.80 0.80 0.80
Keterangan: AFR: Air flow rate (CFM) EWB: Entering Wet Bulb Temp. (°C) EDB: Entering Dry Bulb Temp. (°C) TC: Kapasitas Total Cooling (kW) SC: Kapasitas Sensible Cooling (kW) PI: Power Input (kW) Catatan: 1. Rating yang ditunjukkan adalah kapasitas bersih.. 2. menunjukkan kapasitas nominal. 3. Interpolasi langsung diperbolehkan. Jangan ekstrapolasi. 4. Unit dapat beroperasi pada ambient sekitar 19°C sampai 46°C DB (pendinginan) tanpa kekeliruan tekanan.
21
TC 2.04 2.04 2.08 2.19 2.25 2.25 2.27 2.33 2.48 2.48 2.49 2.52 2.11 2.13 2.18 2.31 2.33 2.34 2.37 2.45 2.57 2.57 2.58 2.63 2.19 2.21 2.28 2.43 2.41 2.42 2.46 2.57 2.65 2.66 2.68 2.74
40°C SC 1.83 2.04 2.08 2.19 1.71 1.99 2.27 2.33 1.68 2.08 2.46 2.52 1.91 2.13 2.18 2.31 1.81 2.12 2.37 2.45 1.78 2.22 2.58 2.63 2.00 2.21 2.28 2.43 1.92 2.25 2.46 2.57 1.89 2.36 2.68 2.74
PI 0.82 0.82 0.82 0.83 0.83 0.83 0.83 0.84 0.85 0.85 0.85 0.85 0.82 0.82 0.83 0.84 0.84 0.84 0.84 0.85 0.86 0.86 0.86 0.86 0.83 0.83 0.84 0.85 0.85 0.85 0.85 0.86 0.86 0.86 0.86 0.87
TC 1.88 1.89 1.94 2.05 2.08 2.08 2.11 2.18 2.30 2.30 2.30 2.34 1.95 1.96 2.03 2.16 2.16 2.16 2.20 2.29 2.38 2.38 2.40 2.45 2.02 2.04 2.13 2.27 2.23 2.24 2.29 2.41 2.45 2.46 2.48 2.56
46°C SC 1.72 1.89 1.94 2.05 1.61 1.88 2.11 2.18 1.59 1.97 2.30 2.34 1.80 1.96 2.03 2.16 1.71 2.01 2.20 2.29 1.68 2.11 2.40 2.45 1.88 2.04 2.13 2.27 1.81 2.13 2.29 2.41 1.79 2.24 2.48 2.56
PI 0.90 0.90 0.90 0.91 0.92 0.92 0.92 0.92 0.93 0.93 0.93 0.94 0.91 0.91 0.91 0.92 0.92 0.92 0.93 0.94 0.94 0.94 0.94 0.95 0.92 0.92 0.92 0.93 0.93 0.93 0.94 0.95 0.95 0.95 0.95 0.96
Data Performa
Model: FTV35A - RV35A Mode Pendinginan AFR (CFM) EWB
16°C
242
19°C
22°C
16°C
298
19°C
22°C
16°C
355
19°C
22°C
EDB 21°C 24°C 27°C 30°C 24°C 27°C 30°C 33°C 27°C 30°C 33°C 36°C 21°C 24°C 27°C 30°C 24°C 27°C 30°C 33°C 27°C 30°C 33°C 36°C 21°C 24°C 27°C 30°C 24°C 27°C 30°C 33°C 27°C 30°C 33°C 36°C
TC 3.32 3.32 3.35 3.45 3.66 3.66 3.67 3.71 4.03 4.03 4.03 4.04 3.45 3.46 3.51 3.65 3.80 3.81 3.83 3.89 4.18 4.19 4.19 4.22 3.58 3.60 3.66 3.84 3.94 3.95 3.99 4.07 4.33 4.33 4.35 4.39
19°C SC 2.41 2.89 3.27 3.45 2.25 2.57 3.18 3.71 2.20 2.68 3.13 3.55 2.51 3.05 3.47 3.65 2.38 2.74 3.38 3.89 2.33 2.86 3.35 3.79 2.62 3.19 3.65 3.84 2.52 2.91 3.58 4.07 2.46 3.04 3.56 4.02
PI 0.82 0.82 0.82 0.83 0.83 0.83 0.83 0.84 0.85 0.85 0.85 0.85 0.83 0.83 0.83 0.84 0.84 0.84 0.84 0.85 0.86 0.86 0.86 0.86 0.84 0.84 0.84 0.85 0.85 0.85 0.85 0.86 0.87 0.87 0.87 0.87
TC 3.20 3.21 3.24 3.35 3.53 3.53 3.54 3.59 3.89 3.89 3.89 3.91 3.33 3.34 3.39 3.55 3.67 3.68 3.70 3.77 4.03 4.04 4.05 4.08 3.45 3.47 3.54 3.73 3.80 3.81 3.85 3.95 4.17 4.18 4.20 4.25
25°C SC 2.35 2.82 3.20 3.35 2.19 2.52 3.11 3.59 2.15 2.63 3.07 3.48 2.45 2.98 3.39 3.55 2.32 2.68 3.31 3.77 2.27 2.80 3.29 3.71 2.56 3.11 3.54 3.73 2.45 2.85 3.51 3.95 2.41 2.98 3.50 3.94
PI 0.89 0.89 0.89 0.89 0.90 0.90 0.90 0.91 0.92 0.92 0.92 0.92 0.90 0.90 0.90 0.91 0.91 0.91 0.91 0.92 0.93 0.93 0.93 0.93 0.90 0.90 0.91 0.92 0.92 0.92 0.92 0.93 0.94 0.94 0.94 0.94
TC 3.08 3.09 3.12 3.25 3.40 3.40 3.42 3.47 3.75 3.75 3.75 3.77 3.20 3.21 3.27 3.44 3.53 3.54 3.56 3.65 3.88 3.89 3.90 3.94 3.32 3.34 3.42 3.61 3.66 3.67 3.71 3.83 4.02 4.02 4.04 4.10
Suhu Outdoor 30°C SC PI TC 2.28 0.96 2.96 2.75 0.96 2.96 3.12 0.96 3.01 3.25 0.97 3.15 2.13 0.98 3.27 2.46 0.98 3.27 3.04 0.98 3.29 3.47 0.98 3.36 2.10 1.00 3.60 2.57 1.00 3.60 3.01 1.00 3.60 3.41 1.00 3.64 2.38 0.97 3.07 2.91 0.97 3.08 3.27 0.97 3.15 3.44 0.98 3.33 2.26 0.99 3.39 2.62 0.99 3.40 3.23 0.99 3.43 3.65 0.99 3.53 2.22 1.01 3.73 2.74 1.01 3.73 3.22 1.01 3.75 3.64 1.01 3.80 2.49 0.98 3.18 3.04 0.98 3.20 3.42 0.98 3.30 3.61 0.99 3.50 2.39 1.00 3.51 2.78 1.00 3.52 3.43 1.00 3.57 3.83 1.01 3.71 2.35 1.02 3.85 2.91 1.02 3.86 3.42 1.02 3.89 3.86 1.02 3.96
35°C SC 2.22 2.69 3.01 3.15 2.07 2.40 2.97 3.36 2.04 2.51 2.95 3.34 2.32 2.84 3.15 3.33 2.20 2.56 3.15 3.53 2.16 2.67 3.15 3.55 2.42 2.96 3.30 3.50 2.33 2.71 3.34 3.71 2.29 2.85 3.35 3.76
PI 1.04 1.04 1.05 1.05 1.06 1.06 1.06 1.07 1.08 1.08 1.08 1.08 1.05 1.05 1.06 1.07 1.07 1.07 1.07 1.08 1.09 1.09 1.09 1.10 1.06 1.06 1.07 1.08 1.08 1.08 1.08 1.09 1.10 1.10 1.10 1.11
TC 2.72 2.72 2.77 2.92 3.00 3.01 3.03 3.11 3.31 3.31 3.32 3.35 2.82 2.83 2.91 3.08 3.11 3.12 3.16 3.27 3.43 3.43 3.45 3.50 2.92 2.94 3.05 3.24 3.22 3.23 3.28 3.43 3.54 3.55 3.58 3.66
40°C SC 2.06 2.51 2.77 2.92 1.93 2.24 2.77 3.11 1.90 2.35 2.77 3.13 2.16 2.65 2.91 3.08 2.05 2.39 2.95 3.27 2.01 2.50 2.95 3.32 2.25 2.76 3.05 3.24 2.17 2.54 3.12 3.43 2.13 2.67 3.14 3.51
PI 1.13 1.13 1.13 1.14 1.15 1.15 1.15 1.16 1.17 1.17 1.17 1.18 1.14 1.14 1.15 1.16 1.16 1.16 1.16 1.17 1.18 1.18 1.19 1.19 1.15 1.15 1.16 1.17 1.17 1.17 1.18 1.19 1.19 1.19 1.20 1.20
TC 2.51 2.52 2.58 2.73 2.78 2.78 2.81 2.90 3.06 3.07 3.07 3.12 2.60 2.62 2.71 2.88 2.88 2.88 2.93 3.06 3.17 3.17 3.19 3.27 2.69 2.72 2.84 3.02 2.97 2.99 3.05 3.21 3.27 3.28 3.31 3.41
46°C SC 1.94 2.37 2.58 2.73 1.82 2.13 2.63 2.90 1.79 2.22 2.63 2.97 2.03 2.50 2.71 2.88 1.93 2.26 2.79 3.06 1.90 2.38 2.80 3.14 2.12 2.60 2.84 3.02 2.05 2.40 2.94 3.21 2.01 2.53 2.98 3.30
PI 1.25 1.25 1.25 1.26 1.27 1.27 1.27 1.28 1.29 1.29 1.29 1.30 1.26 1.26 1.27 1.28 1.28 1.28 1.28 1.29 1.30 1.30 1.31 1.31 1.27 1.27 1.28 1.29 1.29 1.29 1.30 1.31 1.31 1.32 1.32 1.33
Keterangan: AFR: Air flow rate (CFM) EWB: Entering Wet Bulb Temp. (°C) EDB: Entering Dry Bulb Temp. (°C) TC: Kapasitas Total Cooling (kW) SC: Kapasitas Sensible Cooling (kW) PI: Power Input (kW) Catatan: 1. Rating yang ditunjukkan adalah kapasitas bersih.. 2. menunjukkan kapasitas nominal. 3. Interpolasi langsung diperbolehkan. Jangan ekstrapolasi. 4. Unit dapat beroperasi pada ambient sekitar 19°C sampai 46°C DB (pendinginan) tanpa kekeliruan tekanan.
22
Data Performa
Model: FTV50A - RV50A Mode Pendinginan AFR EWB (CFM)
16°C
422
19°C
22°C
16°C
474
19°C
22°C
16°C
531
19°C
22°C
EDB 21°C 24°C 27°C 30°C 24°C 27°C 30°C 33°C 27°C 30°C 33°C 36°C 21°C 24°C 27°C 30°C 24°C 27°C 30°C 33°C 27°C 30°C 33°C 36°C 21°C 24°C 27°C 30°C 24°C 27°C 30°C 33°C 27°C 30°C 33°C 36°C
TC 4.98 4.99 5.03 5.18 5.49 5.50 5.50 5.57 6.04 6.04 6.05 6.07 5.18 5.20 5.26 5.48 5.71 5.72 5.74 5.84 6.27 6.28 6.29 6.33 5.37 5.40 5.49 5.76 5.91 5.93 5.98 6.11 6.49 6.50 6.52 6.58
19°C SC 3.43 4.11 4.66 5.18 3.20 3.66 4.52 5.57 3.13 3.82 4.46 5.06 3.58 4.34 4.93 5.48 3.38 3.90 4.81 5.84 3.31 4.06 4.76 5.38 3.73 4.53 5.20 5.76 3.58 4.14 5.10 6.11 3.50 4.32 5.06 5.71
PI 1.32 1.32 1.32 1.32 1.34 1.34 1.34 1.34 1.36 1.36 1.36 1.36 1.33 1.33 1.33 1.34 1.35 1.35 1.35 1.35 1.37 1.37 1.37 1.38 1.34 1.34 1.34 1.35 1.36 1.36 1.36 1.37 1.39 1.39 1.39 1.39
TC 4.80 4.81 4.86 5.03 5.30 5.30 5.31 5.39 5.83 5.84 5.84 5.87 4.99 5.01 5.08 5.32 5.50 5.51 5.54 5.66 6.05 6.06 6.07 6.12 5.18 5.20 5.31 5.59 5.70 5.72 5.77 5.93 6.26 6.27 6.30 6.38
25°C SC 3.34 4.01 4.55 5.03 3.12 3.58 4.42 5.39 3.06 3.74 4.38 4.96 3.48 4.24 4.82 5.32 3.30 3.81 4.70 5.66 3.23 3.98 4.67 5.28 3.64 4.43 5.06 5.59 3.49 4.05 4.98 5.93 3.42 4.23 4.97 5.61
PI 1.42 1.42 1.42 1.43 1.45 1.45 1.45 1.45 1.47 1.47 1.47 1.48 1.43 1.44 1.44 1.45 1.46 1.46 1.46 1.47 1.49 1.49 1.49 1.49 1.45 1.45 1.45 1.47 1.47 1.47 1.48 1.48 1.50 1.50 1.50 1.51
TC 4.62 4.63 4.69 4.88 5.11 5.11 5.13 5.21 5.62 5.62 5.63 5.66 4.80 4.82 4.91 5.16 5.30 5.31 5.35 5.48 5.83 5.83 5.85 5.91 4.98 5.01 5.13 5.42 5.48 5.50 5.56 5.75 6.02 6.03 6.07 6.16
Suhu Outdoor 30°C SC PI TC 3.25 1.54 4.44 3.92 1.54 4.45 4.44 1.54 4.51 4.88 1.55 4.72 3.04 1.57 4.90 3.50 1.57 4.91 4.33 1.57 4.93 5.21 1.57 5.04 2.98 1.60 5.40 3.65 1.60 5.40 4.29 1.60 5.41 4.85 1.60 5.46 3.39 1.55 4.61 4.14 1.56 4.63 4.69 1.56 4.73 5.16 1.57 4.99 3.21 1.58 5.08 3.72 1.58 5.09 4.60 1.58 5.14 5.48 1.59 5.30 3.15 1.61 5.59 3.89 1.61 5.60 4.58 1.61 5.62 5.17 1.62 5.70 3.54 1.57 4.77 4.32 1.57 4.81 4.92 1.58 4.94 5.42 1.59 5.24 3.40 1.59 5.26 3.95 1.60 5.28 4.87 1.60 5.35 5.75 1.61 5.56 3.34 1.63 5.78 4.14 1.63 5.79 4.87 1.63 5.83 5.48 1.64 5.93
35°C SC 3.16 3.82 4.33 4.72 2.95 3.41 4.22 5.04 2.90 3.57 4.20 4.75 3.30 4.03 4.55 4.99 3.12 3.64 4.49 5.30 3.07 3.80 4.48 5.05 3.44 4.20 4.77 5.24 3.31 3.85 4.75 5.56 3.25 4.05 4.76 5.35
PI 1.67 1.67 1.67 1.69 1.70 1.70 1.70 1.71 1.73 1.73 1.73 1.74 1.68 1.69 1.69 1.71 1.71 1.72 1.72 1.73 1.75 1.75 1.75 1.76 1.70 1.70 1.71 1.73 1.73 1.73 1.73 1.75 1.76 1.76 1.77 1.77
Keterangan: AFR: Air flow rate (CFM) EWB: Entering Wet Bulb Temp. (°C) EDB: Entering Dry Bulb Temp. (°C) TC: Kapasitas Total Cooling (kW) SC: Kapasitas Sensible Cooling (kW) PI: Power Input (kW) Catatan: 1. Rating yang ditunjukkan adalah kapasitas bersih.. 2. menunjukkan kapasitas nominal. 3. Interpolasi langsung diperbolehkan. Jangan ekstrapolasi. 4. Unit dapat beroperasi pada ambient sekitar 19°C sampai 46°C DB (pendinginan) tanpa kekeliruan tekanan.
23
TC 4.08 4.08 4.16 4.38 4.51 4.51 4.54 4.66 4.97 4.97 4.97 5.03 4.23 4.25 4.37 4.62 4.67 4.68 4.73 4.91 5.14 5.15 5.17 5.25 4.38 4.41 4.57 4.85 4.83 4.85 4.92 5.15 5.31 5.32 5.36 5.48
40°C SC 2.94 3.57 4.03 4.38 2.75 3.19 3.95 4.66 2.70 3.34 3.94 4.45 3.07 3.76 4.23 4.62 2.91 3.40 4.19 4.91 2.86 3.56 4.20 4.73 3.21 3.92 4.42 4.85 3.09 3.61 4.44 5.15 3.03 3.79 4.46 4.99
PI 1.81 1.81 1.82 1.83 1.84 1.84 1.85 1.85 1.88 1.88 1.88 1.88 1.83 1.83 1.84 1.86 1.86 1.86 1.86 1.88 1.90 1.90 1.90 1.91 1.84 1.84 1.86 1.88 1.87 1.88 1.88 1.90 1.91 1.91 1.92 1.93
TC 3.76 3.78 3.87 4.09 4.17 4.17 4.21 4.36 4.60 4.60 4.61 4.68 3.90 3.93 4.07 4.32 4.31 4.33 4.39 4.59 4.75 4.76 4.79 4.90 4.03 4.08 4.26 4.53 4.46 4.48 4.57 4.82 4.91 4.92 4.97 5.11
46°C SC 2.76 3.37 3.78 4.09 2.59 3.03 3.74 4.36 2.55 3.17 3.75 4.22 2.89 3.55 3.95 4.32 2.74 3.22 3.96 4.59 2.70 3.38 3.99 4.46 3.02 3.70 4.12 4.53 2.91 3.41 4.18 4.82 2.86 3.59 4.23 4.70
PI 2.00 2.00 2.01 2.02 2.03 2.03 2.04 2.05 2.07 2.07 2.07 2.08 2.01 2.02 2.03 2.05 2.05 2.05 2.06 2.07 2.09 2.09 2.09 2.10 2.03 2.03 2.05 2.07 2.07 2.07 2.08 2.10 2.11 2.11 2.11 2.13
Data Performa
Model: FTV60A - RV60A Mode Pendinginan AFR (CFM)
EWB
16°C
474
19°C
22°C
16°C
537
19°C
22°C
16°C
614
19°C
22°C
EDB 21°C 24°C 27°C 30°C 24°C 27°C 30°C 33°C 27°C 30°C 33°C 36°C 21°C 24°C 27°C 30°C 24°C 27°C 30°C 33°C 27°C 30°C 33°C 36°C 21°C 24°C 27°C 30°C 24°C 27°C 30°C 33°C 27°C 30°C 33°C 36°C
TC 6.08 6.09 6.14 6.33 6.71 6.71 6.72 6.80 7.38 7.38 7.39 7.41 6.33 6.35 6.42 6.69 6.97 6.98 7.02 7.13 7.66 7.67 7.68 7.73 6.56 6.60 6.70 7.04 7.22 7.24 7.30 7.46 7.93 7.94 7.97 8.04
19°C SC 4.19 5.02 5.69 6.33 3.91 4.47 5.52 6.80 3.83 4.67 5.45 6.18 4.37 5.30 6.02 6.69 4.13 4.76 5.87 7.13 4.05 4.97 5.82 6.58 4.56 5.54 6.35 7.04 4.37 5.06 6.23 7.46 4.28 5.27 6.18 6.98
PI 1.48 1.48 1.48 1.49 1.51 1.51 1.51 1.51 1.53 1.53 1.53 1.53 1.50 1.50 1.50 1.51 1.52 1.52 1.52 1.53 1.55 1.55 1.55 1.55 1.51 1.51 1.51 1.53 1.53 1.53 1.54 1.54 1.56 1.56 1.56 1.57
TC 5.87 5.87 5.93 6.15 6.47 6.48 6.49 6.58 7.13 7.13 7.13 7.17 6.10 6.12 6.21 6.50 6.72 6.73 6.77 6.92 7.39 7.40 7.42 7.48 6.32 6.36 6.48 6.83 6.96 6.98 7.05 7.24 7.64 7.66 7.69 7.79
25°C SC 4.08 4.90 5.56 6.15 3.81 4.37 5.40 6.58 3.74 4.57 5.34 6.05 4.26 5.18 5.88 6.50 4.03 4.65 5.74 6.92 3.95 4.86 5.71 6.45 4.44 5.41 6.18 6.83 4.26 4.94 6.09 7.24 4.18 5.17 6.07 6.85
PI 1.60 1.60 1.61 1.62 1.63 1.63 1.63 1.64 1.66 1.66 1.66 1.66 1.62 1.62 1.62 1.64 1.64 1.65 1.65 1.65 1.68 1.68 1.68 1.68 1.63 1.63 1.64 1.65 1.66 1.66 1.66 1.67 1.69 1.69 1.69 1.70
TC 5.65 5.66 5.73 5.96 6.24 6.24 6.26 6.37 6.87 6.87 6.87 6.92 5.87 5.89 5.99 6.30 6.47 6.48 6.53 6.70 7.12 7.12 7.14 7.22 6.08 6.12 6.26 6.62 6.70 6.72 6.79 7.02 7.36 7.37 7.41 7.52
Suhu Outdoor 30°C 35°C SC PI TC SC 3.97 1.74 5.42 3.86 4.79 1.74 5.43 4.67 5.43 1.74 5.51 5.29 5.96 1.75 5.77 5.77 3.71 1.77 5.99 3.61 4.27 1.77 5.99 4.17 5.28 1.77 6.02 5.16 6.37 1.77 6.15 6.15 3.64 1.80 6.60 3.54 4.46 1.80 6.60 4.36 5.24 1.80 6.60 5.13 5.93 1.80 6.67 5.80 4.14 1.75 5.63 4.03 5.05 1.75 5.65 4.93 5.73 1.76 5.78 5.56 6.30 1.77 6.10 6.10 3.92 1.78 6.21 3.82 4.55 1.78 6.22 4.44 5.62 1.79 6.28 5.48 6.70 1.79 6.47 6.47 3.85 1.82 6.83 3.75 4.75 1.82 6.84 4.64 5.59 1.82 6.86 5.47 6.32 1.82 6.96 6.17 4.33 1.77 5.83 4.20 5.28 1.77 5.87 5.14 6.01 1.78 6.04 5.82 6.62 1.79 6.40 6.40 4.15 1.80 6.42 4.04 4.83 1.80 6.45 4.71 5.95 1.80 6.53 5.80 7.02 1.82 6.79 6.79 4.08 1.83 7.06 3.97 5.06 1.83 7.08 4.95 5.94 1.84 7.12 5.81 6.70 1.84 7.25 6.53
PI 1.88 1.88 1.89 1.90 1.92 1.92 1.92 1.92 1.95 1.95 1.95 1.96 1.90 1.90 1.91 1.93 1.93 1.93 1.94 1.95 1.97 1.97 1.97 1.98 1.91 1.92 1.93 1.95 1.95 1.95 1.96 1.97 1.99 1.99 1.99 2.00
TC 4.98 4.99 5.08 5.35 5.50 5.51 5.55 5.69 6.07 6.07 6.08 6.15 5.17 5.19 5.33 5.65 5.70 5.72 5.78 6.00 6.28 6.29 6.31 6.42 5.34 5.39 5.58 5.93 5.90 5.92 6.02 6.29 6.49 6.50 6.55 6.70
40°C SC 3.59 4.36 4.92 5.35 3.36 3.90 4.82 5.69 3.30 4.08 4.82 5.44 3.75 4.60 5.16 5.65 3.56 4.15 5.12 6.00 3.50 4.35 5.13 5.77 3.92 4.79 5.40 5.93 3.77 4.40 5.42 6.29 3.71 4.63 5.45 6.09
PI 2.04 2.04 2.05 2.07 2.08 2.08 2.08 2.09 2.12 2.12 2.12 2.12 2.06 2.06 2.07 2.09 2.10 2.10 2.10 2.12 2.14 2.14 2.14 2.15 2.08 2.08 2.09 2.12 2.11 2.12 2.12 2.14 2.16 2.16 2.16 2.17
TC 4.60 4.61 4.73 5.00 5.09 5.09 5.15 5.32 5.62 5.62 5.63 5.72 4.76 4.80 4.97 5.28 5.27 5.29 5.37 5.61 5.81 5.82 5.85 5.98 4.93 4.98 5.20 5.54 5.44 5.47 5.58 5.88 5.99 6.01 6.07 6.25
46°C SC 3.38 4.11 4.62 5.00 3.16 3.70 4.56 5.32 3.11 3.87 4.58 5.16 3.53 4.34 4.83 5.28 3.35 3.93 4.84 5.61 3.30 4.13 4.87 5.45 3.69 4.52 5.04 5.54 3.55 4.17 5.11 5.88 3.50 4.39 5.17 5.74
PI 2.25 2.25 2.26 2.28 2.29 2.29 2.29 2.31 2.33 2.33 2.34 2.34 2.27 2.27 2.29 2.31 2.31 2.31 2.32 2.34 2.35 2.36 2.36 2.37 2.29 2.29 2.31 2.34 2.33 2.33 2.34 2.36 2.37 2.38 2.38 2.40
Keterangan: AFR: Air flow rate (CFM) EWB: Entering Wet Bulb Temp. (°C) EDB: Entering Dry Bulb Temp. (°C) TC: Kapasitas Total Cooling (kW) SC: Kapasitas Sensible Cooling (kW) PI: Power Input (kW) Catatan: 1. Rating yang ditunjukkan adalah kapasitas bersih.. 2. menunjukkan kapasitas nominal. 3. Interpolasi langsung diperbolehkan. Jangan ekstrapolasi. 4. Unit dapat beroperasi pada ambient sekitar 19°C sampai 46°C DB (pendinginan) tanpa kekeliruan tekanan.
24
Garis Besar & Dimensi
Garis Besar & Dimensi Unit Indoor Model: FTV-A
TANDA
MENUNJUKKAN ARAH PEMIPAAN A
BELAKANG
BELAKANG
KANAN
KIRI
KANAN
C
NAME PLATE
B
SIGNAL RECEIVER
ON/OFF SWITCH BAWAH LOUVER
TAMPAK SAMPING
THERMISTOR SUHU RUANGAN (DI DALAM)
FRONT GRILLE FIXED SCREWS (DI DAAM)
Recommended mounting plate retention spots (7 spots in all) F
Recommended mounting plate retention spots (5 spots in all) D
E
D
E
F
F
TERMINAL BLOCK WITH EARTH TERMINAL
TERMINAL BLOCK WITH EARTH TERMINAL
UNIT INDOOR B OTTOM BAWAH
B
TAMPAK ATAS
F
G
B
Through the wall hole Ø 65mm
GB
G
Through the wall hole Ø 65mm
H
J
Drain hose position L
K
M
Liquid pipe end
Liquid pipe end
H J
I
L
A
Gas pipe end
Gas pipe end M
K K
I
Drain hose position
A
Mounting plate installation FTV50/60
Mounting plate installation FTV15/20/25/35
Semua dimensi dalam mm
Model
A
B
C
FTV15/20/25/35A
800
288
206
1065
310
233
FTV50/60A
Catatan: Dimensi dalam mm
25
Garis Besar & Dimensi
Unit outdoor Model: RV-A D
E
F H G
H A
C M
L
N O B
K J I
Dimensi Model RV15/20/25A
A
B
C
566 463 256
D
E
F
G
H
89 366 111 297 30
P
Q
I
J
K
L
M
N
O
P
Q
22
63
55
70
117
41
167
85 43
Catatan: Dimensi dalam mm
\
Dimensi Model RV35A
A
B
550 658
C
D
51 11
E
F
G
273
16 14
H
I
J
K
L
M
470
96
93
94
60 14
N
O
133 8
P
Q
10
299
Catatan: Dimensi dalam mm
26
N M Q
Garis Besar & Dimensi
K
L
E
NF
L
A
O
D
C G
H
I
J
3.0 U
P
B
R S
V
T
Dimensi Model RV50/60A Dimensi Model RV50/60A
A
D
E
F
G
H
628 328
520
179
46
93
149
O
P
R
S
T
U
V
34
23
73
75
67
7
855
B
C
Q 362
8
I 101
J
K
L
M
N
113
603
126
164
15
Catatan: Dimensi dalam mm
27
Diagram Pemipaan
Diagram Pemipaan Unit Indoor Model: FTV15/20/25A
Unit Outdoor Model: RV15/20/25A
28
Diagram Pemipaan
Heat pump Unit indoor Model: FTV35A
29
Unit outdoor Model: RV35A
Diagram Pemipaan
Unit indoor Model: FTV50/60A
Unit outdoor Model: RV50/60A
30
Servis & Perawatan
Servis & Perawatan Perhatian • Lepaskan koneksi dari suplai utama sebelum servis AC. • Unit dirancang untuk memberikan umur operasi yang panjang dengan perawatan minimum yang diperlukan. Namun, harus teratur diperiksa dan item berikut harus diperhatikan.
Komponen 1. Filter Udara (Unit indoor)
2. 3. 1.
Unit indoor
2.
Prosedur Perawatan Keluarkan debu yang menempel pada filter dengan menggunakan penyedot debu atau cuci dengan air hangat (di bawah 40 °C) dengan detergen pembersih netral. Bilas saringan dengan baik dan keringkan sebelum meletakkannya kembali ke unit. Catatan: Jangan pernah menggunakan bensin, zat mudah menguap atau bahan kimia untuk membersihkan filter. Bersihkan kotoran atau debu di atas kisi atau panel dengan menyekanya dengan kain lembut yang direndam dalam air hangat (di bawah 40°C) dan larutan deterjen netral. Catatan: Jangan pernah menggunakan bensin, zat mudah menguap atau bahan kimia membersihkan unit indoor
Drain Pan & Pipa 1. Periksa kebersihan dan bersihkan jika perlu. 2. Periksa aliran air kondensat. Drain Periksa apakah ada suara yang tidak normal. Indoor Fan
Periode Sedikitnya sekali setiap 2 minggu. Lebih sering jika diperlukan.
Sedikitnya sekali setiap 2 minggu. Lebih sering jika diperlukan.
Setiap 3 bulan Jika diperlukan
Coil Indoor / Outdoor
1. Periksa dan bersihkan kotoran di antara sirip. 2. Periksa dan lepaskan penghalang yang menghambat aliran udara ke indoor maupun outdoor.
Setiap bulan
Setiap 2 bulan
Catu Daya
1. Periksa arus dan tegangan yang mengalir untuk unit indoor dan outdoor. 2. Periksa kabel listrik dan kencangkan kabel blok terminal jika perlu.
Kompresor
Tidak perlu perawatan jika sirkuit refrigeran tetap tertutup rapat. Setiap 6 bulan Namun, periksa kebocoran refrigeran pada sambungan dan fitting.
Model Indoor
Setiap Tahun
Cerukpada
1. Buka panel depan • Pegang panel di ceruk pada unit utama (2 ceruk di sisi kanan dan kiri) dan angkat sampai berhenti. 2. Lepas panel depan • Saat mengangkat panel depan lebih jauh, geser ke kanan dan tarik ke sisi depan. Poros putar sebelah kiri terlepas. Geser poros putar sebelah kanan ke kiri dan tarik ke sisi depan untuk melepaskannya. 3. Pasang panel depan • Luruskan poros putar kanan dan kiri panel depan dengan alur dan dorong keduanya masuk. • Tutup panel depan dengan hati-hati. (Dorong kedua ujung dan bagian tengah panel depan).
Unit utama
Poros Putar
\
Perhatian • Jangan menyentuh bagian logam unit indoor. Hal ini dapat menyebabkan cedera. • Saat melepas atau memasang panel depan, gunakan bangku yang kuat dan stabil dan perhatikan langkah Anda dengan saksama. • Saat melepaskan/memasang panel depan, tahan panel dengan tangan untuk mencegahnya terjatuh. • Untuk pembersihan, jangan gunakan air panas di atas 40 ° C, bensin benzena, thinner, atau minyak atsiri lainnya, • Setelah dibersihkan, pastikan panel depan terpasang dengan benar. 31
Penyelesaian Masalah
Penyelesaian Masalah Lampu Indikator Penerima Sinyal IR Bila sinyal operasi remote control infra merah telah dikirim, penerima sinyal pada unit indoor akan merespons seperti di bawah ini untuk mengkonfirmasi penerimaan transmisi sinyal. ON ke OFF OFF ke ON Pump down/Pendinginan Paksa ON
1x Bip panjang
Others
1x Bip pendek
2x Bip pendek
Unit Pendingin / Unit Heat pump Tabel di bawah ini menunjukkan lampu indikator LED untuk unit AC dalam kondisi normal dan kondisi saat terjadi kesalahan. Lampu LED terletak di tengah unit AC. Unit Heat pump dilengkapi dengan mode sensor "auto" yang akan memberikan suhu ruangan yang wajar dengan beralih secara otomatis ke mode "cool" atau "heat" sesuai dengan suhu yang ditetapkan oleh pengguna.
Penerima IR Cool Timer Sleep ON/OFF
tombol ON/OFF
Penerima IR
32
Penyelesaian Masalah
Lampi LED Indoor: Kondisi operasi normal dan saat terjadi kerusakan untuk unit pendingin.
Kode Kerusakan
Operasi Normal / Indikasi Kerusakan
Tindakan
COOL (HIJAU)
Hijau
1 kali
berulang
-
Mode Pendinginan
-
-
Timer menyala
-
-
Mode Sleep ON
-
-
Mode Fan ON
-
-
Mode Dry ON
-
Kedip E1
Kontak sensor udara ruangan longgar / konslet
Telepon Dealer Anda
Kedip E2
Sensor coil terbuka
Telepon Dealer Anda
Kedip E4
Kompresor overload / sensor koil indoor konslet
Telepon Dealer Anda
Kedip E5
Bocor gas
Telepon Dealer Anda
Kedip E8
Hardware eror
Telepon Dealer Anda
Kedip E9
Tidak ada umpan balik dari kipas indoor
Telepon Dealer Anda
2 kali
1 kali
3 kali
6 kali
berulang
ON
4 kali
ON or OFF
Kedip
Catatan: Unit tidak akan mendeteksi hilang sensor saat kompresor menyala.
33