MP5S/MP5Y/MP5W Series
Pulse Meter
High Performance, Digital Panel Meter
(A) Photoelectric Sensors
Features
3 types of operation mode are added. (total 16 types of operation mode) Frequency/Revolutions/Speed, Passing speed, Cycle, Passing time, Time interval, Time differential , Absolute ratio, Error ratio, Density, Error, Length measurement 1, Length measurement 2, Interval, Accumulation, Addition/Subtraction-individual input, Addition/ Subtraction-phase difference input Various output models Relay triple/quintuple output, NPN/PNP open collector quintuple output, BCD dynamic output, PV transmission output (current output), RS485 communication output (changed Modbus RTU) Various functions Selectable NPN solid state/contact input, PNP solid state/contact input, prescale, delay monitoring, hysteresis, auto-zero time setting, lock setting, data bank function (MP5W series) Max. display range: -19999 to 99999 Various display units rpm, rps, Hz, kHz, sec, min, m, mm, mm/s, m/s, m/min, m/h, ℓ/s, ℓ/min, ℓ/h, %, counts, etc.
Shaded parts ( ) are changed and added functions from previous MP5.
(C) Door/Area Sensors (D) Proximity Sensors (E) Pressure Sensors
MP5S
(F) Rotary Encoders (G) Connectors/ Connector Cables/ Sensor Distribution Boxes/Sockets (H) Temperature Controllers
MP5Y
MP5W
(I) SSRs / Power Controllers
Please read “Safety Considerations” in operation manual before using.
(J) Counters
Ordering Information
MP 5 Y - 4 N Output
(K) Timers
S
N
Y
N 1 2 3 4 5 6
Indicator NPN open collector quintuple output PNP open collector quintuple output Indicator Indicator Indicator Relay triple output (H, GO, L)
BCD dynamic output PV transmission output (current output) RS485 communication output -
N
-
1 2
Indicator Relay quintuple output (HH, H, GO, L, LL) Relay triple output (H, GO, L) NPN open collector quintuple output
4
NPN open collector quintuple output
PV transmission output (current output)
5 8
PNP open collector quintuple output NPN open collector quintuple output
PV transmission output (current output) RS485 communication output
9
PNP open collector quintuple output
RS485 communication output
W
Size Digits Item
2
24VAC 50/60Hz, 24-48VDC
4
100-240VAC 50/60Hz
S Y W
DIN W48×H48mm DIN W72×H36mm DIN W96×H48mm
5
99999 (5-digit)
MP
Pulse meter
Sub output (display value output) -
(L) Panel Meters
Main output (comparative value output) Indicator
A
Power supply
(B) Fiber Optic Sensors
-
(M) Tacho / Speed / Pulse Meters (N) Display Units (O) Sensor Controllers (P) Switching Mode Power Supplies (Q) Stepper Motors & Drivers & Controllers
BCD dynamic output
(R) Graphic/ Logic Panels (S) Field Network Devices (T) Software
M-7
MP5S/MP5Y/MP5W Series Specifications Series Display method Character size Display range AC voltage Power supply AC/DC voltage Power consumption
AC voltage AC/DC voltage
Permissible voltage range External power supply Sub power supply Input frequency
Input method
Measurement range Measurement accuracy (23℃±5℃) Display cycle Operation mode
Output
Prescale function Hysteresis Relay triple Relay quintuple Main NPN/PNP open collector quintuple BCD dynamic Sub PV transmission Communication Memory retention Insulation resistance Dielectric strength Noise immunity Mechanical Vibration Malfunction Mechanical Shock Malfunction Mechanical Relay life cycle Electrical Ambient temp. Environment Ambient humi. Approval ※2 Weight
MP5S MP5Y MP5W 7-segment LED (zero blanking method) W4×H8mm W7×H14mm -19999 to 99999 100-240VACᜠ 50/60Hz 24VACᜠ 50/60Hz, 24-48VDCᜡ Max. 7.5VA Max. 9VA Max. 15VA (100-240VACᜠ 50/60Hz) (100-240VACᜠ 50/60Hz) (100-240VACᜠ 50/60Hz) Max. 6VA (24VACᜠ 50/60Hz), Max. 7VA (24VACᜠ 50/60Hz), Max. 11VA (24VACᜠ 50/60Hz), max. 4.5W (24-48VDCᜡ) max. 6.2W (24-48VDCᜡ) max. 7W (24-48VDCᜡ) 90 to 110% of rated voltage Max. 12VDCᜡ ±10% 80mA Max. 24VDCᜡ 30mA ·Solid state input 1: max. 50kHz (pulse width: min. 10㎲) ·Solid state input 2: max. 5kHz (pulse width: min. 100㎲) ※For F7, F8, F9, F10 operation mode, max. 1kHz (pulse width: min. 500㎲) ·Contact input: max. 45Hz (pulse width: min. 11ms) [Voltage input] High: 4.5-24VDCᜡ, Low: 0-1VDC, Input impedance: 3.9kΩ [No-voltage input] Short-circuit impedance: Max. 80Ω, Residual voltage: Max. 1VDC, Open-circuit impedance: Min. 100kΩ : 0.0005Hz to 50kHz ·Operation mode F1, F2, F7, F8, F9, F10 : 0.01 to max. of each time range ·Operation mode F3, F4, F5, F6 : 0 to 99999 ·Operation mode F11, F12, F13, F16 : -19999 to 99999 ·Operation mode F14, F15 : F.S.±0.05%rdg±1-digit ·Operation mode F1, F2, F7, F8, F9, F10 : F.S.±0.01%rdg±1-digit ·Operation mode F3, F4, F5, F6 OFF (for F2, F16 operation mode), 0.05, 0.5, 1, 2, 4, 8 sec (same as update output cycle) Frequency/Revolutions/Speed (F1), Passing speed (F2), Cycle (F3), Passing time (F4), Time interval (F5), Time differential (F6), Absolute ratio (F7), Error ratio (F8), Density (F9), Error (F10), Length measurement 1 (F11), Interval (F12), Accumulation (F13), Addition/Subtraction-individual input (F14), Addition/Subtraction-phase difference input (F15), Length measurement 2 (F16) Direct input method (0.0001×10-9 to 9.9999×109) ※1 0 to 9999 250VACᜠ 3A resistive load 250VACᜠ 3A resistive load -
Max. 30VDCᜡ 30mA
Max. 30VDCᜡ 30mA DC4-20mA/DC0-20mA max. load 500Ω RS485 communication output (Modbus RTU method) Non-volatile memory (number of inputs: 100,000 operations) Over 100MΩ (at 500VDC megger) 2,000VAC 60Hz for 1 min ±2kV the square wave noise (pulse width: 1㎲) by the noise simulator 0.75mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 1 hour 0.5mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 10 min 300m/s² (approx. 30G) in each X, Y, Z direction for 3 times 100m/s² (approx. 30G) in each X, Y, Z direction for 3 times Min. 10,000,000 operations Min. 100,000 operations (250VAC 3A resistive load) -10 to 50℃, storage: -20 to 60℃ 35 to 85%RH, storage: 35 to 85%RH Approx. 191g (approx. 132g)
Approx. 230g (approx. 140g)
※1: Setting range will vary depending on the decimal point. ※2: The weight includes packaging. The weight in parenthesis is for unit only. ※Environment resistance is rated at no freezing or condensation.
M-8
Approx. 334g (approx. 210g)
Pulse Meter Connections
(A) Photoelectric Sensors
※Terminal connections differ by power supply and output type of each series and model.
MP5S Series
Brown
Blue
Black
Black
(B) Fiber Optic Sensors
8
9
(C) Door/Area Sensors
INA INB +12V 0V HOLD/RESET
6 ※1: Operation mode F1 to F12 : display value HOLD Operation mode F13 to F16 : display value RESET ※2: Model Source
MP5S-4N
10
11
(E) Pressure Sensors
12
1
24-48VDC 24VAC 50/60Hz 100-240VAC 50/60Hz
MP5S-2N
7
(D) Proximity Sensors
※1
2
3
4
(F) Rotary Encoders (G) Connectors/ Connector Cables/ Sensor Distribution Boxes/Sockets
5
(H) Temperature Controllers
- + ※2 SOURCE
(I) SSRs / Power Controllers
MP5Y Series Power/Input Terminal (Common)
(J) Counters
※MP5Y- N (indicator) only has 'Power/Input terminals'.
Black Black
1
2
INA
INB
(K) Timers
Blue Brown
3
4
5
0V HOLD/RESET
6
7
+12V
※1
-
+
SOURCE
(L) Panel Meters
※1: O peration mode F1 to F12 : display value HOLD Operation mode F13 to F16 : display value RESET ※2: Model Source 24-48VDC MP5Y-2 24VAC 50/60Hz 100-240VAC MP5Y-4 50/60Hz
(M) Tacho / Speed / Pulse Meters (N) Display Units (O) Sensor Controllers
※2
(P) Switching Mode Power Supplies
O utput Connector (MP5Y- 1 to 5)
(Q) Stepper Motors & Drivers & Controllers
※Hirose connector: HIF3BA-10PA-2.54DS ※Hirose connector socket: HIF3BA-10D-2.54R (sold separately) ※Hirose connector socket is not included. Contact a hirose connector dealer regarding sockets and cables.
● MP5Y- 1 (NPN open collector output)
● MP5Y- 2 (PNP open collector output)
MAIN OUT (NPN OPEN COLLECTOR) 30VDC 30mA
MAIN OUT (PNP OPEN COLLECTOR) 30VDC 30mA
GO
HH
LL
GO
HH
(T) Software
4
6
8
10
2
4
6
8
10
1
3
5
7
9
1
3
5
7
9
H
L
COM
H
(S) Field Network Devices
LL
2
COM
(R) Graphic/ Logic Panels
L
M-9
MP5S/MP5Y/MP5W Series ● MP5Y- 3 (BCD dynamic output)
● MP5Y- 4 (PV transmission output)
BCD OUT (NPN OPEN COLLECTOR) 30VDC 30mA A
C
D0
D2
DC4-20mA/DC0-20mA (+) Load 500Ω Max.
D4
2
4
6
8
10
2
4
6
8
10
1
3
5
7
9
1
3
5
7
9
COM
B
D1
D
D3
(-)
※Autonics display unit (DS/DA Series) is recommended for stable minus (-) sign display.
●Output Terminal (MP5Y- 6)
● MP5Y- 5 (RS485 communication otuput)
● MP5Y- 6 (Relay triple output)
RS485 B(-)
2
4
6
8
10
1
3
5
7
9
8
9
10
11
H
12 13 14 15
GO
L
CONTACT OUT: 250VAC 3A RESISTIVE LOAD
RS485 A(+)
MP5W Series ●Power/Input Terminal (Common) ※MP5W- N (indicator) only has 'Power/Input terminals'.
Black Black
※1: Operation mode F1 to F12 : display value HOLD Operation mode F13 to F16 : display value RESET ※2: Model Source 24-48VDC MP5W-2 24VAC 50/60Hz 100-240VAC MP5W-4 50/60Hz
1 INA
2 INB
Blue
3
4
5
Brown
6
7
0V
0V ※1
HOLD/RESET
●Output Terminal (MP5W- A/1)
9 - + ※2 SOURCE
BANK
● MP5W- A (Relay quintuple output)
8
+12V
● MP5W- 1 (Relay triple output)
CONTACT OUT: 250VAC 3A RESISTIVE LOAD
CONTACT OUT: 250VAC 3A RESISTIVE LOAD
H
10
11
12
13
14
15
HH
H
GO
L
LL
COM
M-10
10
GO
11
12
L
13
14
15
Pulse Meter Output Connector (MP5W- 2/4/5/8/9)
(A) Photoelectric Sensors
※Hirose connector: HIF3BA-20PA-2.54DS ※Hirose connector socket: HIF3BA-20D-2.54R (sold separately) ※Hirose connector socket is not included. Contact a hirose connector dealer regarding sockets and cables. ※1: Sub power supply ※2: POL signal turns ON when the display value is a minus (-) value.
(B) Fiber Optic Sensors
● MP5W- 2 (NPN open collector+BCD dynamic output) MAIN OUT (NPN OPEN COLLECTOR) 30VDC 30mA +24VDC ※ 30mA Max. 1 LL HH GO D B
(C) Door/Area Sensors
D1
D3
DOT COM2
2
4
6
8
10
12
14
16
18
20
1
3
5
7
9
11
13
15
17
19
COM
H
L
A
0V
(D) Proximity Sensors (E) Pressure Sensors (F) Rotary Encoders
※2
C D4 D0 POL D2 BCD OUT (NPN OPEN COLLECTOR) 30VDC 30mA
(G) Connectors/ Connector Cables/ Sensor Distribution Boxes/Sockets
※Autonics display unit (DS/DA Series) is recommended for stable minus (-) sign display.
● MP5W- 4 (NPN open collector+PV transmission output)
● MP5W- 5 (PNP open collector+PV transmission output) MAIN OUT (PNP OPEN COLLECTOR) 30VDC 30mA
MAIN OUT (NPN OPEN COLLECTOR) 30VDC 30mA +24VDC ※ 30mA Max. 1 HH GO LL
HH
(+)
2
4
6
8
10
12
14
16
18
20
1
3
5
7
9
11
13
15
17
19
COM H
L
0V
1 COM
6
3 H
5 L
8 7 0V
4
6
1
3
5
(K) Timers
(L) Panel Meters
L
(M) Tacho / Speed / Pulse Meters (N) Display Units
● MP5W- 9 (PNP open collector+RS485 comm. output)
MAIN OUT (NPN OPEN COLLECTOR) 30VDC 30mA +24VDC ※ 30mA Max. 1 HH GO LL
4
2
COM H
10 9
RS485 B(-)
12 11
14 13
16 15
18 17
(I) SSRs / Power Controllers
(J) Counters
LL
(-) DC4-20mA/DC0-20mA (Load 500Ω Max.)
● MP5W- 8 (NPN open collector+RS485 comm. output)
2
GO
(H) Temperature Controllers
20 19
(O) Sensor Controllers
MAIN OUT (PNP OPEN COLLECTOR) 30VDC 30mA HH
GO
(P) Switching Mode Power Supplies
LL
2
4
6
(Q) Stepper Motors & Drivers & Controllers
1
3
5
(R) Graphic/ Logic Panels
COM H
L
(S) Field Network Devices
A(+) RS485
(T) Software
M-11
MP5S/MP5Y/MP5W Series Dimensions
(unit: mm)
※Nameplate design is changed from the previous MP5. ※Side dimensions of MP5Y/W differ by output type.
●MP5S Series
10
90
45
48
●MP5Y Series
MP5Y- 1/2/3/4/5
72
89.5
MP5Y- 6
14.5
15.3
36
30
6
10.5
10.5
※M P5Y- N (indicator) does not include the shaded part (output hirose connector or output terminal).
MP5W- 2/4/5/8/9
96
MP5W- A/1 10.5
14.5
89.5
6
48
45
●MP5W Series
10.5
10.5 ※MP5W- N (indicator) does not include the shaded part (output hirose connector or output terminal).
Panel cut-out dimensions A
(unit: mm) D
MP5S MP5Y MP5W
C
C
D
45.5 68 92
+0.5 0
+0.7 0 +0.8 0
45.5 31.5 45
+0.5 0 +0.5 0
+0.6 0
For MP5Y/W
41 4.2
B
Min. 55 Min. 62 Min. 91 Min. 40 Min. 116 Min. 52
3
3.9
Bracket For MP5S
A
15
12.2 16.4 48.6
M-12
42.2 45.4 47.8 61.64
73
6
4 1
9.5
0.82
0.2±0.2
4.5
45.4 50 61
12±0.2
30
10
B
Series
Size
M3
Pulse Meter Unit Description
●MP5S Series
●MP5Y Series
(A) Photoelectric Sensors
●MP5W Series 4
4
(B) Fiber Optic Sensors
1
1
1
(C) Door/Area Sensors (D) Proximity Sensors
2
3
2 3 1: Display component Displays current value in RUN mode. Alternately displays setting parameters and corresponding value in SETTING mode. 2: key In RUN mode, press the key once to check max./min. value. In RUN mode, hold the key for over 2 sec to enter parameter groups. 3: , , key Select parameter groups, and select or setting values in the corresponding parameters. 4: O utput status indicator
2
(E) Pressure Sensors
3
(F) Rotary Encoders (G) Connectors/ Connector Cables/ Sensor Distribution Boxes/Sockets
Sold Separately
Communication converter SCM-WF48
(Wi-Fi to RS485·USB wireless communication converter)
(H) Temperature Controllers
SCM-38I
SCM-US48I
(RS232C to RS485 converter)
(USB to RS485 converter)
(I) SSRs / Power Controllers
(J) Counters
(K) Timers
(L) Panel Meters
Display Units (DS/DA-T Series)
(M) Tacho / Speed / Pulse Meters
DS/DA-T Series (RS485 communication input type display unit)
(N) Display Units
DS16- T DS22/DA22- T DS40/DA40- T DS60/DA60- T ※Connect RS485 communication input type display unit (DS/DA-T Series) and RS485 communication output model of MP5Y/MP5W Series, the display unit displays present value of the device without PC/PLC.
(P) Switching Mode Power Supplies
Input Specifications
Input Specifications
1. Input signal
(Q) Stepper Motors & Drivers & Controllers
Standard duty ratio of input signal is 1:1. ON (1) Solid state input 1 OFF Input frequency: Max. 50kHz (ON/OFF pulse width: min. 10㎲ of each) Pulse width (2) S olid state input 2 OFF ON Input frequency: Max. 5kHz (ON/OFF pulse width: min. 100㎲ of each) ※For F7, F8, F9, F10 operation mode, max. 1kHz (ON/OFF pulse width: min. 500㎲ of each) T (3) Contact input ① Input frequency: Max. 45Hz (when each ON/OFF pulse width is over 11ms) ※T: s ingle cycle of input signal ② Contact specifications: 12VDC, stable switching of load current as small as 5mA
(R) Graphic/ Logic Panels (S) Field Network Devices
2. Input type [IN-A, IN-B]
(T) Software
IN 0V (COM)
MP5
3.9kΩ
Sensor circuit
Sensor circuit
0V (COM)
3.9kΩ
Sensor circuit
IN
Sensor circuit
Sensor circuit
MP5 allows selection between NPN input (solid state/contact) or PNP input (solid state/contact). (1) NPN input type (2) PNP input type ①Contact ②NPN voltage ③NPN open collector ①Contact ②PNP voltage ③PNP open collector output type sensor output type sensor output type sensor output type sensor MP5 +12V +12V Sensor circuit
(O) Sensor Controllers
M-13
MP5S/MP5Y/MP5W Series Output Specifications
1. Relay output
① Output: Comparative or alarm output (refer to " Output Modes") ② Output type: Relay ③ Contact capacity: 250VAC 3A resistive load ④ Life cycle: [Mechanical] min. 10,000,000 operations (switching frequency 180 operations/min) [Electrical] min. 100,000 operations (3A 250VAC, 30VDC resistive load) (switching frequency 20 operations/min)
2. Transistor output
① Output: Comparative output or alarm output (refer to " ② Output type: NPN/PNP open collector ③ Rated load voltage: 30VDC ④ Max. load current: 30mA
Output Modes")
3. BCD dynamic output (negative logic)
① Output: present value ② Output signal: BCD data (A, B, C, D, DOT) ← A: lowest bit, DOT: highest bit Digit data (D0, D1, D2, D3, D4) ← D0: lowest digit, D4: highest digit ③ Output type: NPN open collector ④ Rated load voltage: 30VDC ⑤ Max. load current: 30mA ⑥ Dynamic COM cycle (T) = 40ms
E.g.) To display value = 125.89 by BCD dynamic output 104-digit 100-digit PV display value
1
2
5.
8
9
A B
BCD Data
C D DOT D0 0.1ms
D1 Digit
D2 D3 D4
5ms
8ms
40ms
4. PV transmission output
① Application: transmit measured value ② Function: transmit measured value within setting range of high-limit output [FS-H] to low-limit output [FS-L] after conversion into DC4-20mA or DC0-20mA current. ③O utput range of high/low-limit ·High-limit [FS-H] range: From min. value to max. value within measurement range ·Low-limit [FS-L] range: From min. value to max. value within measurement range ([FS-H]≥[FS-L]+1) (1) DC4-20mA transmission output (2) DC0-20mA transmission output ① Transmit measured value within setting range of high-limit ① Transmit measured value within setting range of high-limit output [FS-H] to low-limit output [FS-L] after conversion output [FS-H] to low-limit output [FS-L] after conversion into into DC4-20mA current. DC0-20mA current. ② Resistive load: Max. 500Ω ② Resistive load: Max. 500Ω ③ Resolution: 8000 divisions ③ Resolution: 10,000 divisions Diplay value FS-H
Display value FS-H
FS-L Set [FS-L] and [FS-H] and the output is DC4-20mA. If the setting width between [FS-L] and [FS-H] is lower than 8000 divisions, the resolution is also reduced.
FS-L 20mA
4mA
Set [FS-L] and [FS-H] and the output is DC0-20mA. If the setting width between [FS-L] and [FS-H] is lower than 10,000 divisions, the resolution is also reduced.
20mA 0mA
5. RS485 communication output Comm. protocol Connection type Application standard Max. connection Synchronous method Comm. method Comm. distance
Modbus RTU RS485 Compliance with EIA RS485 31 units (address: 01 to 99) Asynchronous Two-wire half duplex Max. 800m
Communication Speed
2400, 4800, 9600 (default), 19200, 38400 bps
Communication response time Start Bit Data Bit Parity Bit Stop Bit
5 to 99ms (default: 20ms) 1-bit fixed 8-bit fixed None (default), Even, Odd 1, 2-bit (default)
※For more information about RS485 communication output specifications, refer to ' RS485 Communication Output'.
M-14
Pulse Meter Parameter Groups
(A) Photoelectric Sensors
Parameter 0 group
(max./min. monitoring value)
RUN mode
2 sec
HOLD/RESET
3 sec
(B) Fiber Optic Sensors
※
※Operation mode F1 to F12 : display value HOLD Operation mode F13 to F16 : display value RESET
(C) Door/Area Sensors (D) Proximity Sensors
Parameter 1/2/3 group ※Press the , , keys to select or set the desired value. ※Press the key once after changing the setting value, to save the setting value and move to the next parameter. ※Hold the key for 1.5 sec at any parameters to return to the select parameter group mode. ※Hold the key for 3 sec to save the setting value and return to RUN mode after changing the setting value. ※If there is no key input for 60 sec while setting the parameters, the new settings are ignored, and the unit will return to RUN mode with previous settings. ※The dotted line parameters may not appear depending on output specifications or other parameter settings. Please refer to ' Operation Mode by Parameter Group'. ※1: Each parameter and corresponding setting value will flash alternately every 0.5 sec.
● Parameter 0 group
(E) Pressure Sensors (F) Rotary Encoders (G) Connectors/ Connector Cables/ Sensor Distribution Boxes/Sockets (H) Temperature Controllers (I) SSRs / Power Controllers
RUN mode
(J) Counters
PStHH
PSt H
PSt L
PStLL
Flashes ※1 alternately
99999
99999
HH comparative value ※Does not appear in F output mode
H comparative value
(K) Timers
※The parameters are identical to [PStHH], [PSt H], [PSt L], [PStLL] of parameter 2 group and the setting values will be linked. ●Setting range by operation mode Operation mode Setting range F1, F2, F7, F9, F11, 0 to 99999 F12, F13, F16 F3, F4, F5, F6
00000
00000
L comparative value
LL comparative value ※Does not appear in F output mode,
0 to setting time range
`9999 to 99999 F8, F10, F14, F15 (the setting range varies depending on the decimal point setting.) ※Only appears in comparative value setting models.
(L) Panel Meters (M) Tacho / Speed / Pulse Meters (N) Display Units (O) Sensor Controllers (P) Switching Mode Power Supplies (Q) Stepper Motors & Drivers & Controllers
hPEK
99999
Max. monitoring value
(R) Graphic/ Logic Panels
※Resetting monitoring value :H old the key for over 2 sec (reset current value)
lPEK
`9999
(S) Field Network Devices
Min. monitoring value
(T) Software
M-15
MP5S/MP5Y/MP5W Series ● Parameter 1 group 2 sec
RUN mode 3 sec
MODE
Flashes ※ alternately 1
PARa1
F ㄹ 1
PARa2
Operation mode ●Setting range: F1 to F16
●Setting range Parameter Input sensor type NPnhF NPN solid state input 1 NPnmF NPN solid state input 2 NPnlF NPN contact input PNphF PNP solid state input 1 PNpmF PNP solid state input 2 PNplF PNP contact input
IN-A
NPnhF
Sensor type of input A
IN-B
NPnhF
Sensor type of input B
OUT-T
STARD
●Setting range Parameter Output mode STARD S (Standard) Output mode OUT-H H (High) OUT-L L (Low)
HYS
0001
GUARD
fDEFY STArT
PARa3
Parameter OUT-B OUT-I OUT-F
Output mode B (Block) I (One-shot) F (Deflection)
Output hysteresis ●Setting range: 0000 to 9999 (the setting range varies depending on the decimal point setting.)
LL, L comparative output limit function
9(9 Start compensation timer function & compensation time ●Setting range: )0 to 9(9 (sec)
AUToA
999(9
Auto-zero time for input A ●Setting range: )1 to 999(9 (sec)
M-16
AUToB
999(9
MEMO
OFF
Auto-zero time for input B
Memory retention ●Setting range: ㅒㅜON, OFF
※Does not appear in indicator models.
Pulse Meter ● Parameter 2 group
RUN mode
2 sec
PARa1
PARa2
(A) Photoelectric Sensors
PARa3
(B) Fiber Optic Sensors
3 sec
pBANK
Flashes ※ alternately 1
1
(C) Door/Area Sensors
Data bank ●Setting range: 1, 2 ※Only appears in MP5W.
(D) Proximity Sensors
DOT
tUNT
00000
Decimal point location of display value ●Setting range: 00000, 000)0, 00)00, 0)000, )0000
tSEC
99(99
tMIN
99(99
Time unit and range ●Setting range tSEC (sec) 99(99 999.99s 999(9 9999.9s 9(5(9 99m 59.9s (5(59 9h 59m 59s 99999 99999s
PStHH
99999
HH comparative value ※Does not appear in F output mode
PSt H
99999
H comparative value
PSt L
PStLL
PScaH
00000
L comparative value
00000
LL comparative value ※Does not appear in F output mode
^0000
PScaY
10 01
PScbH
^0000
PScbY
10 01
(E) Pressure Sensors (F) Rotary Encoders
tMIN (min) 99(99 999.99m 999(9 9999.9m 9(5(9 99h 59.9m 99(59 999h 59m 99999 99999m
(G) Connectors/ Connector Cables/ Sensor Distribution Boxes/Sockets (H) Temperature Controllers
※The parameters are identical to [PStHH], [PSt H], [PSt L], [PStLL] of parameter 0 group and the setting values will be linked. ●Setting range by operation mode Operation mode Setting range F1, F2, F7, F9, F11, 0 to 99999 F12, F13, F16 F3, F4, F5, F6 0 to set time range `9999 to 99999 F8, F10, F14, F15 (the setting range varies depending on the decimal point setting.) ※Only appears in comparative value setting models.
(I) SSRs / Power Controllers
(J) Counters
(K) Timers
(L) Panel Meters (M) Tacho / Speed / Pulse Meters (N) Display Units
Prescale mantissa (X) of input A ●Setting range: )0001 to (9999
(O) Sensor Controllers (P) Switching Mode Power Supplies
Prescale exponent (y) of input A ●Setting range: 10 - 9 (10-9) to 10 09 (109)
(Q) Stepper Motors & Drivers & Controllers
Prescale mantissa (X) of input B ●Setting range: )0001 to (9999
(R) Graphic/ Logic Panels (S) Field Network Devices
Prescale exponent (y) of input B ●Setting range: 10 - 9 (10-9) to 10 09 (109)
(T) Software
DISpT
)05
COUnB
99999
Display cycle of measured value ●Setting range: )05, )5, 1, 2, 4, 8 (sec) ※Setting range in operation mode F2, F16 : OFF, )05, )5, 1, 2, 4, 8 (sec) Setting value of input B ●Setting range: 1 to 99999
M-17
MP5S/MP5Y/MP5W Series ● Parameter 3 group
RUN mode
2 sec
PARa1
PARa2
PARa3
3 sec
●Setting range by operation mode Operation mode Setting range F1, F2, F7, F9, F11, F12, 0 to 99999 F13, F16 F3, F4, F5, F6 0 to set time range `9999 to 99999 F8, F10, F14, F15 (the setting range varies depending on the decimal point setting.) ※Only appears in PV transmission output models.
99999
High-limit value of PV transmission output
FS-L
00000
Low-limit value of PV transmission output
MA
4-20
ADDR
01
B ㅜㅠ PS
9600
Communication speed ●Setting range: 9600, 19200, 38400, 2400, 4800 (bps)
P ㅜ RTY
NONE
Communication parity bit ●Setting range: NONE (none), EVEN (even), ODD (odd)
FS-H
STP
M-18
Flashes ※ alternately 1
2
RSwT
20
COmW
D ㅇ ISA
LOC
OFF
Current output specifications ●Setting range: 4-20, 0-20 Communication address ●Setting range: 01 to 99
※Only appears in RS485 comm. output models.
Communication stop bit ●Setting range: 1, 2
Communication response wait time ●Setting range by communication speed Communication speed (unit: bps) 2400 4800 9600, 19200, 38400
Setting range (unit: ms) 16 to 99 8 to 99 5 to 99
Communication write ●Setting range: ENA (enable), DISA (disable)
Lock ●Setting range Parameter OFF LOc0 LOc1 LOc2 LOc3
Function Unlock Lock all Parameter 1/2/3 lock Parameter 2/3 lock Parameter 3 lock
Pulse Meter Operation Mode by Parameter Groups Parameter
Operation mode PStHH
0 group
PSt H PSt L
F1
F2
F3
F4
F5
F6
F7
( : parameter display, X: no parameter display) F8
F9
F10
F11
F12
F13
F14
F15
F16
※1 ※2
(B) Fiber Optic Sensors (C) Door/Area Sensors
Appears in all operation modes (F1 to F16).
※2
(A) Photoelectric Sensors
※1
PSt LL
(D) Proximity Sensors
hPEK lPEK MODE IN-A
1 group
IN-B OUT-T HYS GVARD
(E) Pressure Sensors
Appears in all operation mode (F1 to F16). ※3 ※2
※4
※2
(F) Rotary Encoders (G) Connectors/ Connector Cables/ Sensor Distribution Boxes/Sockets
※2
AVToA
(H) Temperature Controllers
AVToB MEMO
(I) SSRs / Power Controllers
※Only appears in MP5W. Appears in all operation modes (F1 to F16).
pBANK DOT
(J) Counters
tUNT PStHH
2 group
PSt H PStLL PSt L
※1 ※2 ※2
(K) Timers
Appears in all operation modes (F1 to F16).
※1
(L) Panel Meters
PScaH
(M) Tacho / Speed / Pulse Meters
PScaY PScbH PScbY DISpT
(N) Display Units
※5
COUnB FS-H
(O) Sensor Controllers
※Only appears in PV transmission output models. Appears in operation modes (F1 to F16).
FS-L
(P) Switching Mode Power Supplies
ㅡMA 3 group
ADDR
(Q) Stepper Motors & Drivers & Controllers
BPS ※Only appears in RS485 comm. output models. Appears in all operation modes (F1 to F16).
PRTY STP
(R) Graphic/ Logic Panels
REwT
(S) Field Network Devices
COmW LOC ※1: Only appears in only for quintuple output models. ※2: Only appears in triple, quintuple output models. ※3: The settings for IN-B and IN-A are applied. ※4: ( ) F output mode [OUT-F] cannot be set. ※5: ( ) setting range: OFF, )05, )5, 1, 2, 4, 8
(T) Software
Monitoring delay function by output mode Output mode Parameter Comparative output limit Start compensation timer
S mode H mode L mode B mode I mode F mode STARD OVT-; OVT-L OVT-B OVT-I OVT-F
M-19
MP5S/MP5Y/MP5W Series Operation Modes [MODE] Select operation mode from operation mode[MODE]of parameter 1 group.. MP5 has 16 operation modes.
F1 Mode: Frequency/Revolutions/Speed
Measures the frequency of input A and displays the calculated frequency, revolutions, and speed. 1) Frequency (Hz)
=f×α
(α= 1[sec])
2) Revolutions (rpm)
=f×α
(α= 60[sec])
3) Speed (m/min)
=f×α
(α= 60L[sec])
※L: travel distance of conveyor belt of 1 pulse cycle[m] α: prescale value 60L For multiple objects, α = N
MP5 Encoder
Display value and display unit Display value Frequency Revolutions
Speed
Display unit
α (prescale value)
Hz
1
kHz
0.001
rps
1
rpm (default)
60
mm/sec
1,000L
cm/sec
100L
m/sec
1L
m/min
60L
km/hour
3.6L
Timing chart Input A t1
Hold input
t2
t3
t4
1 α 1 α t1 t2
Display
Display value
Passing speed
α (prescale value)
mm/sec
1,000L
cm/sec
100L
m/sec (default)
1L
m/min
60L
km/hour
3.6L
t6
1 α t5
1 α t6
MP5
Sensor B Sensor A
Timing chart
Display unit
t5
1 α t3
F2 Mode: Passing Speed Displays the passing speed between input A ON and input B ON. Passing speed (V) = f × α (α = L[m]) ※f : reciprocal of time [sec] between input A (sensor) ON and input B (sensor) ON. L: distance between input A (sensor) and input B (sensor) [m] α: prescale value
Display value and display unit
MP5
Input A Input B Hold input
ta t1
Display
t2 1 α t1
t3 1 t2 α
t4
t5 t6 t7 1 1 1 α α t6 t4 t7 α
1 t3 α
※ta: Return time (over 20ms)
F3 Mode: Cycle Displays the measured time from Input A ON to the next ON. Cycle (T) = t ※t: measurement time[sec]
Photoelectric sensor
Display value and display unit ([tUNT] of parameter 2) Display value
Display unit Sec
Min
999.99s (default) 999.99m Cycle
M-20
9999.9s
9999.9m
99m59.9s
99h59.9m
9h59m59s
999h59m
99999s
99999m
MP5
Timing chart Input A Hold input Display
t1
t2
t3
t1
t2
t4
t5 t3
t6 t5
t6
Pulse Meter F4 Mode: Passing Time
(A) Photoelectric Sensors
Measures the time from Input A ON to the next ON, and displays the passing time of the arbitrary distance. Passing time[sec]= t × α (α=
(B) Fiber Optic Sensors
L[m] ) Distance advanced in 1 pulse cycle [m]
※t : measured time[sec], L : arbitrary distance[m] α: prescale value
en
Display value and display unit ([tUNT] of parameter 2) Display value
Passing time
L:L
MIN
999.99s (default)
999.99m
9999.9s
9999.9m
99m59.9s
99h59.9m
9h59m59s
999h59m
99999s
99999m
(D) Proximity Sensors
MP5
Display unit SEC
(C) Door/Area Sensors
m] gth[
(E) Pressure Sensors
Timing chart Input A t1
Hold input Display
t2
t3
t4
t1 α
t2 α
t5
(F) Rotary Encoders
t6 t5 α
t3 α
t6 α
(G) Connectors/ Connector Cables/ Sensor Distribution Boxes/Sockets (H) Temperature Controllers (I) SSRs / Power Controllers
F5 Mode: Time Interval Displays measured time of Input A ON Time interval (T) = t ※t: measured time of input A ON [sec]
MP5 Motor
Display value and display unit ([tUNT] of parameter 2) Display value
Time interval
(J) Counters
Stamp
Display unit SEC
MIN
999.99s (default)
999.99m
9999.9s
9999.9m
99m59.9s
99h59.9m
Hold input
9h59m59s
999h59m
Display
99999s
99999m
(K) Timers
Timing chart
(L) Panel Meters
Input A t1
ta
t2
ta
(M) Tacho / Speed / Pulse Meters
t3
t1
t3
t2
(N) Display Units
※ta: Return time (over 20ms)
(O) Sensor Controllers
F6 Mode: Time Differential Displays measured time from Input A ON to Input B ON. Time differential (T) = t (ta to tb) ※t (ta to tb): measured time from input A ON to input B ON [sec]
(Q) Stepper Motors & Drivers & Controllers
Display value and display unit ([tUNT] of parameter 2) Display value
Display unit SEC
Time difference
MIN
999.99s (default)
999.99m
9999.9s
9999.9m
99m59.9s
99h59.9m
9h59m59s
999h59m
99999s
99999m
(P) Switching Mode Power Supplies
MP5
Sensor B
(R) Graphic/ Logic Panels
Sensor A
Timing chart
(S) Field Network Devices
Input A Input B Hold input Display
ta t1
(T) Software
t2 t1
t3 t2
t4 t3
t5
t6 t4
t7 t6
t7
※ta: Return time (over 20ms)
M-21
MP5S/MP5Y/MP5W Series F7 Mode: Absolute Ratio
Measures and displays relative speed, amount, speed, etc. of input B against input A in percentage (%). Absolute ratio = (Input B / Input A) × 100% Frequency of input B[Hz] × Bα Absolute ratio = × 100[%] Frequency of input A[Hz] × Aα
Flow meter A
Flow meter B
MP5
Liquid
※Aα: Prescale value of input A, Bα: Prescale value of input B
Display value and display unit Display value
Display unit
Absolute ratio
%
※Hold: When the hold signal turns ON, the display value is maintained until the display cycle turns to hold OFF.
Timing chart Input A
fA
Input B
fB
Display =
Frequency of input B[Hz] × Bα × 100[%] Frequency of input A[Hz] × Aα
F8 Mode: Error Ratio
Measures and displays the relative rate of input B against the reference value of input A in percentage (%). Input B-Input A Error ratio = × 100[%] Input A
Conveyor A Conveyor B
(Frequency of input B [Hz] × Bα)Error ratio = (Frequency of input A[Hz] × Aα) × 100[%] Frequency of input A[Hz] × Aα ※Aα: prescale value of input A, Bα: prescale value of input B
Display value and display unit Display value
Display unit
Error ratio
%
MP5
Timing chart
Input A fA Input B
※Hold: When the hold signal turns ON, the display value is maintained until the display cycle turns to hold OFF.
fB
F9 Mode: Density
Measures and displays the density ratio (%) of input B against the total sum of input A and input B. Input B Density = × 100[%] Input A + Input B Frequency of Input B[Hz] × Bα Density = × 100[%] (Frequency of input A[Hz] × Aα) + (Frequency of input B[Hz] × Bα) ※Aα: Prescale value of input A, Bα: Prescale value of input B
Display value and display unit Display value
Display unit
Density
%
Flow meter A
MP5
Flow meter B
Liquid
Timing chart Input A fA Input B
※Hold: When the hold signal turns ON, the display value is maintained until the display cycle turns to hold OFF.
fB
F10 Mode: Error
Conveyor A
Measures and displays the error of input B against reference value of input A. Error = Input B - Input A Error = (Frequency of input B[Hz] × Bα) - (Frequency of input A[Hz] × Aα) ※Aα: prescale value of input A, Bα: prescale value of input B Display value and display unit Display value
Display unit
Error
END User setting
※Hold: When the hold signal turns ON, the display value is maintained until the display cycle turns to hold OFF.
MP5
Timing chart
Input A fA Input B fB
M-22
Conveyor B
Pulse Meter F11 Mode: Length Measurement 1
(A) Photoelectric Sensors
Measure and display the number of input A pulses during input B ON.
Input A
Length measurement = P × α ※P: Number of input A pulses, α: Prescale value
Display value and display unit Display value
Display unit Quantity (default) mm
Length measurement
cm m
(B) Fiber Optic Sensors
Photoelectric sensor
MP5
Timing chart Input A
Input B
(C) Door/Area Sensors
1 2 3 4 5 6
1 2
1 2 3 4 (D) Proximity Sensors
Input B tb
ta
Hold input
6 α
Display
2 α
4 α
※ta, tb: return time (over 20ms)
F12 Mode: Interval
Display value and display unit Display value
Interval
Display unit
Photoelectric sensor
Timing chart Input A
mm
Input B
m
(G) Connectors/ Connector Cables/ Sensor Distribution Boxes/Sockets (H) Temperature Controllers
Quantity (default) cm
(F) Rotary Encoders
MP5
Measures and displays the number of input A pulses from Input B ON to the next ON. Interval = P × α ※P: Number of input A pulses, α: Prescale value
1 2 3 4 5
1 2 3 4
(I) SSRs / Power Controllers
1 2 3
(J) Counters
ta
Hold input
(K) Timers
5×α
Display
4×α (L) Panel Meters
※ta: return time (over 20ms)
(M) Tacho / Speed / Pulse Meters
F13 Mode: Accumulation Measures and displays the counted value of input A pulses. Accumulation = P × α ※P: Number of input A pulses, α: Prescale value
(N) Display Units
MP5
Display value and display unit Display value
Display unit
Accumulation
Quantity[EA]
Operation
①Counts the number of input A pulses. ②Input B is an enable input signal. During ON, the quantity and display value of input A will be held, and during OFF input A will be re-counted. ③When RESET input is ON, the integrated counted value will be reset to "0".
(E) Pressure Sensors
(O) Sensor Controllers
Timing chart Input A Input B RESET Display 0
1
1
2
3
2 3
4
5 6
4
5 6
1
0
1
2 3
4
2 3 4
※α=1 display value
(P) Switching Mode Power Supplies (Q) Stepper Motors & Drivers & Controllers (R) Graphic/ Logic Panels (S) Field Network Devices (T) Software
M-23
MP5S/MP5Y/MP5W Series F14 Mode: Addition/Subtraction-Individual Input
MP5
Displays the counted value from added input A pulses and subtracted input B pulses. When there are two inputs simultaneously, it will not count. Addition/Subtraction = Input A × α - Input B × β ※α: Prescale value of input A, β: Prescale value of input B
Display value and display unit Display value
Display unit
Addition/ Subtraction (individual input)
Quantity
Operation and timing chart
Pulse of input A is added, and pulse of input B is subtracted.
Photoelectric Input A sensor
(addition)
Timing chart
H L H Input B L RESET H L Input A
Display 0
1
2 32
Display value and display unit Display value
Display unit
Up/Down counting (phase difference input)
Quantity
Display value
Display unit
Length measurement 2
Quantity[EA]
※If input A and input B are ON during initial power supply, it will not count and only count the number of rising edge. ※Display value is renewed depending on the display cycle [DISpT] setting.
M-24
2
3
2 1
Input B MP5
Timing chart H L H Input B L RESET H L Input A
0
1
2 3
2
1
0
1 2 0
Timing chart (e.g.) setting value of Input B=4
Measures and displays the number of pulses from input A until the value of input B reaches the set value. H Input A L Length measurement 2 = P × α (until the setting value of Input B) H Input B L ※P: Number of input A pulses, α: Prescale value
Display value and display unit
1
Input A
Display
F16 Mode: Length Measurement 2
0
※α, β=1 display value
F15 Mode: Addition/Subtraction- Phase difference input When input A is low, counting is added to the low of input B. When input A is low, counting is subtracted from the high of input B. Addition/Subtraction (phase difference) = Detects position and speed using A and B phases of encoder outputs as input.
Input B (subtraction)
1
2
1
2
3
4
1
2
3
H RESET L 1 2 3 4 0 1 2 3 4 5 6 7 0 1 2 3 4 5
Display Display
※1
0
7
※1: W hen the display cycle [DISpT] setting is OFF, it will maintain the quantity of input A until the value of input B reaches the setting value B [COUnB].
Pulse Meter Output Modes [OUT-T]
(A) Photoelectric Sensors
MP5 Series supports 6 output modes. (There is no output mode in indicator models). Requirement for setting comparative value: (B output mode) LL