4 0 3 MB
NetNumen U31 Alarm Management Operation
Contents
Alarm Management Overview
Alarm Management Parameters
Alarm Monitoring
Alarm Data Maintenance
2
Composition of alarm Management System
© ZTE All rights reserved
3
Alarm Management Architecture NMS
EMS Alarm Reporting
Alarm Display Topo
NE Alarm Select Tree
Resource Moudle
Common Alarm Alarm Command
Alarm Location
NE
Alarm Reporting
Alarm Command
Alarm Access Moudle
Low-layer Network Management
© ZTE All rights reserved
Alarm Access Moudle
4
Easy Monitoring and Operation Just alarms we want
Key Alarms
Display Filter
Correlation Rules Dump Filter Access Filter
Original Alarms NE
© ZTE All rights reserved
IP devices
Detailed alarm information helps user to handle alarm.
Default and customized suggestions, accumulating and sharing maintenance experience. 5
Alarm Management System Principle
© ZTE All rights reserved
6
Alarm Management Window
1. Navigation tree © ZTE All rights reserved
2. Active alarm area 7
3. Historical alarm area
Alarm Management Function
Real-time alarm monitoring
© ZTE All rights reserved
Specific
Alarm
Alarm
Alarm
alarm query
display
reporting
processing
8
Alarm Management Terms Alarm
Alarm
Active
clearing
alarm
Alarm
Historical
management
alarm
system
Notification
Alarm type
Alarm
Alarm code
© ZTE All rights reserved
masking 9
Notification A notification is a prompt that occurs during the daily operation of the NetNumen U31 (RAN) EMS to remind maintenance personnel of system operation
status.
A notification indicates the occurrence of a
momentary event, but does not indicate potential danger. A notification does not need to be cleared unless it occurs repeatedly.
Usually a notification is a system prompt, and does
not affect services. However, under some certain circumstances, a notification will affect services.
© ZTE All rights reserved
10
Alarm Classification By system type • Alarms generated from a
managed device • Alarm box and NetNumen U31 (RAN) EMS
communication link alarms • Interruption of the
communication link with the upper-level EMS • Front end and back end
communication link alarm • Performance management alarm
By fault type • Communications alarms
• Critical alarm
• Processing error alarms
• Major alarm
• Quality of service alarms
• Minor alarm
• Equipment alarms
• Warning alarm
• Environmental alarms • OMC alarms • Integrity violation alarms • Operational violation
alarms • Physical violation alarms • Security violation alarms
• Performance data collection delay alarm © ZTE All rights reserved
By alarm level
11
Alarm Status
© ZTE All rights reserved
12
Alarm Management Technical Specifications
© ZTE All rights reserved
13
Contents
Alarm Management Overview
Alarm Management Parameters
Alarm Monitoring
Alarm Data Maintenance
14
Alarm Management Parameters
© ZTE All rights reserved
15
Setting the Alarm Box
1. In the EMS client, select Fault>Setting>Alarm Box Setting. The Set the Alarm Box window is displayed.
2. Click + on the toolbar. The Alarm Box dialog
box is displayed.
© ZTE All rights reserved
16
Setting Alarm Sounds and Colors
© ZTE All rights reserved
17
Setting Special Alarm Prompts
1. In the EMS client, select Fault>Setting>Alarm Prompting Setting. The Alarm Prompting Setting window is displayed. 2. Click + on the toolbar. The Alarm Prompting Setting dialog box is displayed.
© ZTE All rights reserved
18
Setting the Criteria for Determining an Intermittent Alarm 1. In the EMS client, select Fault>Setting>Intermittent Alarm Setting. The Intermittent Alarm Setting window is displayed. 2. Click + on the toolbar. The Intermittent Alarm Setting dialog box is displayed.
© ZTE All rights reserved
19
Setting an Automatic Alarm Processing RuleCreating an Alarm Rule
© ZTE All rights reserved
20
Example: Setting an Automatic Alarm Processing Rule-Alarm Acknowledging Rule
© ZTE All rights reserved
21
Suppressing Alarms Generated by a Scheduled Task
1. In the EMS client, select Fault>Suppress Plan Task Management. The Suppress Plan Task Management window is displayed. 2. Click +. The Suppress Plan Task dialog box is displayed.
© ZTE All rights reserved
22
Setting TOP Alarm Suppression Rules 1. In the EMS client, select Alarm>Setting>TO P Alarm Suppress Setting. The TOP Alarm Suppression Setting window is displayed. 2. Click +. The TOP Alarm Suppression Setting dialog box is displayed.
© ZTE All rights reserved
23
Setting the Alarm Forwarding Template
© ZTE All rights reserved
24
Redefining Alarm Levels
© ZTE All rights reserved
25
Adding Alarm Handling Suggestions
Maintenance personnel can add alarm handling methods and maintenance experience to alarm information for the reference of other maintenance personnel’s handling of the same type of alarms.
© ZTE All rights reserved
26
Contents
Alarm Management Overview
Alarm Management Parameters
Alarm Monitoring
Alarm Data Maintenance
27
Alarm Monitoring Flow
© ZTE All rights reserved
28
Setting the Alarm Forwarding Rule
In the EMS client window, select
Fault>Setting>Rule Setting. The Set Rules
window is displayed.
Click + on the toolbar. The New dialog box is displayed.
Select Alarm
Forwarding Rule. Click OK. The Alarm
Forwarding Rule dialog box is displayed.
Set related parameters on the Basic, Condition,
and Action tabs. Click OK.
© ZTE All rights reserved
29
Alarm Monitoring Methods Alarm Monitoring Method
Operation Reference
Monitor alarms through the Alarm Monitoring window
Alarm monitoring is used to monitor Active alarms or notifications and historical alarms. Select Alarm>Alarm Monitoring. The Alarm Monitoring window is displayed.
Monitor alarms through the Topology Management window
NE alarm monitoring: In the EMS window, select Topology>Set Alarm Display Mode>Display NE Monitoring Alarm Table. Key-alarms monitoring: Select Topology>Set Alarm Display Mode>Display Key Monitoring Alarm Table. The Display Key Monitoring Alarm Table is displayed in the lower part of the window.
Monitor alarms through the alarming board
By default, the system summarizes network-wide alarms by alarm level on the upper right corner of the client window. Select Alarm>Alarming Board. The Alarming Board dialog box is displayed.
Manually query alarms
Maintenance personnel can query alarms in accordance with the default template or customized conditions, or by NE or NE group. In the navigation tree in the Alarm Management windown, right-click Customized Query>My Query. Select New Active alarm Query from the shortcut menu.
Create a periodical alarm output task
A periodical alarm output task can periodically output Active alarms or historical alarms on the system to a file. The output result file can be uploaded to a specified FTP server. Select Alarm>Periodical Output Task Management. The Periodical Output Task Management window is displayed.
View diagnosis results through an RRU fault analyzer
Usually, if an RRU alarm is raised, an RRU fault analyzer can be used to diagnose hardware on the EMS. In the Alarm Monitoring window, right-click an LTE TDD or RRU alarm, and select RRU Fault Analyzer from the shortcut menu.
© ZTE All rights reserved
30
Viewing and Locating an Alarm
In the Fault Management window of the EMS client, double-click an alarm. The
Alarm Details dialog box is displayed.
© ZTE All rights reserved
31
Viewing and Locating an Alarm
View historical alarm information about the Active alarm for the reference of alarm handling and analysis.
In the EMS client window, select Fault>Alarm Monitoring. The Alarm Monitoring window is displayed.
Right-click an alarm. Select Related History Alarms (Position) from the
shortcut menu. The History Alarms page is displayed.
View the historical alarm information about the alarm.
Locate the physical position of the alarm through the alarm location operation.
Locate the alarm to the NE: The system automatically opens the Topology Management window, and selects the NE where the alarm is generated.
Locate the alarm to the rack view: The system automatically opens the page where the rack view is located. Maintenance personnel can view the faulty board on the rack view.
© ZTE All rights reserved
32
Manually Forwarding the Alarm
© ZTE All rights reserved
33
Troubleshooting the Alarm & Recording Alarm Handling Suggestions
© ZTE All rights reserved
34
Contents
Alarm Management Overview
Alarm Management Parameters
Alarm Monitoring
Alarm Data Maintenance
35
Alarm Data Maintenance
© ZTE All rights reserved
36
Manually Synchronizing Alarms 1. In the EMS client, select Fault>Synchronize Active Alarms. The
Synchronize Active Alarms dialog box is displayed. 2. In the navigation tree on the left, select one
or multiple NEs. Click ->. Add them to selected NEs. 3. Click OK.
© ZTE All rights reserved
37
Manually Collecting Statistics on Alarms
© ZTE All rights reserved
38
Basic Alarm Statistics
© ZTE All rights reserved
39
Busy-Time Alarm Statistics
© ZTE All rights reserved
40
Important Alarm Code Statistics
© ZTE All rights reserved
41
Customizing a Statistics Template
© ZTE All rights reserved
42
Creating Query Conditions
© ZTE All rights reserved
43
Copying and Pasting a Query Condition
© ZTE All rights reserved
44
Alarm Statistics Display
Pie chart
Histogram Table © ZTE All rights reserved
45
Managing a Periodical Statistics/Export Task
© ZTE All rights reserved
46
Setting an Automatic Historical Alarm Acknowledgement Task
In the EMS client, select Maintenance>Task Management>Show Timing Task. The Task Management window is displayed.
In the navigation tree on the left, click Common Task>Alarm Background Task>Automatically Acknowledge
History Alarms Setting. The number of days of the scheduled task and period information are displayed on Click here to edit the right. the number of days
© ZTE All rights reserved
47
Manually Backing up or Restoring Alarm Data
In the EMS client window, select Maintenance>System Backup and Restore. The Backup and Restoration window is displayed.
In the navigation tree on the left, click Backup and Restore>Backup/Restore>Backup and Deletion Alarm Data. The Configure Parameters of Backup and Deletion page is displayed on the right.
Backup and deletion
Data restoration
© ZTE All rights reserved
48
Exporting or Importing Alarm Handling Suggestions
In the EMS client window, select Fault>Setting>Handling Suggestions Setting. The Handling Suggestion Setting window is displayed.
© ZTE All rights reserved
49
Thank you