NetNumen U31 Alarm Management Operation



Contents 



Alarm Management Overview







Alarm Management Parameters







Alarm Monitoring







Alarm Data Maintenance



2



Composition of alarm Management System



© ZTE All rights reserved



3



Alarm Management Architecture NMS



EMS Alarm Reporting



Alarm Display Topo



NE Alarm Select Tree



Resource Moudle



Common Alarm Alarm Command



Alarm Location



NE



Alarm Reporting



Alarm Command



Alarm Access Moudle



Low-layer Network Management



© ZTE All rights reserved



Alarm Access Moudle



4



Easy Monitoring and Operation Just alarms we want



Key Alarms



Display Filter



Correlation Rules Dump Filter Access Filter



Original Alarms NE



© ZTE All rights reserved



IP devices







Detailed alarm information helps user to handle alarm.







Default and customized suggestions, accumulating and sharing maintenance experience. 5



Alarm Management System Principle



© ZTE All rights reserved



6



Alarm Management Window



1. Navigation tree © ZTE All rights reserved



2. Active alarm area 7



3. Historical alarm area



Alarm Management Function



Real-time alarm monitoring



© ZTE All rights reserved



Specific



Alarm



Alarm



Alarm



alarm query



display



reporting



processing



8



Alarm Management Terms Alarm



Alarm



Active



clearing



alarm



Alarm



Historical



management



alarm



system



Notification



Alarm type



Alarm



Alarm code



© ZTE All rights reserved



masking 9



Notification A notification is a prompt that occurs during the daily operation of the NetNumen U31 (RAN) EMS to remind maintenance personnel of system operation



status.



A notification indicates the occurrence of a



momentary event, but does not indicate potential danger. A notification does not need to be cleared unless it occurs repeatedly.



Usually a notification is a system prompt, and does



not affect services. However, under some certain circumstances, a notification will affect services.



© ZTE All rights reserved



10



Alarm Classification By system type • Alarms generated from a



managed device • Alarm box and NetNumen U31 (RAN) EMS



communication link alarms • Interruption of the



communication link with the upper-level EMS • Front end and back end



communication link alarm • Performance management alarm



By fault type • Communications alarms



• Critical alarm



• Processing error alarms



• Major alarm



• Quality of service alarms



• Minor alarm



• Equipment alarms



• Warning alarm



• Environmental alarms • OMC alarms • Integrity violation alarms • Operational violation



alarms • Physical violation alarms • Security violation alarms



• Performance data collection delay alarm © ZTE All rights reserved



By alarm level



11



Alarm Status



© ZTE All rights reserved



12



Alarm Management Technical Specifications



© ZTE All rights reserved



13



Contents 



Alarm Management Overview







Alarm Management Parameters







Alarm Monitoring







Alarm Data Maintenance



14



Alarm Management Parameters



© ZTE All rights reserved



15



Setting the Alarm Box 



1. In the EMS client, select Fault>Setting>Alarm Box Setting. The Set the Alarm Box window is displayed.







2. Click + on the toolbar. The Alarm Box dialog



box is displayed.



© ZTE All rights reserved



16



Setting Alarm Sounds and Colors



© ZTE All rights reserved



17



Setting Special Alarm Prompts



1. In the EMS client, select Fault>Setting>Alarm Prompting Setting. The Alarm Prompting Setting window is displayed. 2. Click + on the toolbar. The Alarm Prompting Setting dialog box is displayed.



© ZTE All rights reserved



18



Setting the Criteria for Determining an Intermittent Alarm 1. In the EMS client, select Fault>Setting>Intermittent Alarm Setting. The Intermittent Alarm Setting window is displayed. 2. Click + on the toolbar. The Intermittent Alarm Setting dialog box is displayed.



© ZTE All rights reserved



19



Setting an Automatic Alarm Processing RuleCreating an Alarm Rule



© ZTE All rights reserved



20



Example: Setting an Automatic Alarm Processing Rule-Alarm Acknowledging Rule



© ZTE All rights reserved



21



Suppressing Alarms Generated by a Scheduled Task



1. In the EMS client, select Fault>Suppress Plan Task Management. The Suppress Plan Task Management window is displayed. 2. Click +. The Suppress Plan Task dialog box is displayed.



© ZTE All rights reserved



22



Setting TOP Alarm Suppression Rules 1. In the EMS client, select Alarm>Setting>TO P Alarm Suppress Setting. The TOP Alarm Suppression Setting window is displayed. 2. Click +. The TOP Alarm Suppression Setting dialog box is displayed.



© ZTE All rights reserved



23



Setting the Alarm Forwarding Template



© ZTE All rights reserved



24



Redefining Alarm Levels



© ZTE All rights reserved



25



Adding Alarm Handling Suggestions 



Maintenance personnel can add alarm handling methods and maintenance experience to alarm information for the reference of other maintenance personnel’s handling of the same type of alarms.



© ZTE All rights reserved



26



Contents 



Alarm Management Overview







Alarm Management Parameters







Alarm Monitoring







Alarm Data Maintenance



27



Alarm Monitoring Flow



© ZTE All rights reserved



28



Setting the Alarm Forwarding Rule 



In the EMS client window, select



Fault>Setting>Rule Setting. The Set Rules



window is displayed. 



Click + on the toolbar. The New dialog box is displayed.







Select Alarm



Forwarding Rule. Click OK. The Alarm



Forwarding Rule dialog box is displayed. 



Set related parameters on the Basic, Condition,



and Action tabs. Click OK.



© ZTE All rights reserved



29



Alarm Monitoring Methods Alarm Monitoring Method



Operation Reference



Monitor alarms through the Alarm Monitoring window



Alarm monitoring is used to monitor Active alarms or notifications and historical alarms. Select Alarm>Alarm Monitoring. The Alarm Monitoring window is displayed.



Monitor alarms through the Topology Management window



NE alarm monitoring: In the EMS window, select Topology>Set Alarm Display Mode>Display NE Monitoring Alarm Table. Key-alarms monitoring: Select Topology>Set Alarm Display Mode>Display Key Monitoring Alarm Table. The Display Key Monitoring Alarm Table is displayed in the lower part of the window.



Monitor alarms through the alarming board



By default, the system summarizes network-wide alarms by alarm level on the upper right corner of the client window. Select Alarm>Alarming Board. The Alarming Board dialog box is displayed.



Manually query alarms



Maintenance personnel can query alarms in accordance with the default template or customized conditions, or by NE or NE group. In the navigation tree in the Alarm Management windown, right-click Customized Query>My Query. Select New Active alarm Query from the shortcut menu.



Create a periodical alarm output task



A periodical alarm output task can periodically output Active alarms or historical alarms on the system to a file. The output result file can be uploaded to a specified FTP server. Select Alarm>Periodical Output Task Management. The Periodical Output Task Management window is displayed.



View diagnosis results through an RRU fault analyzer



Usually, if an RRU alarm is raised, an RRU fault analyzer can be used to diagnose hardware on the EMS. In the Alarm Monitoring window, right-click an LTE TDD or RRU alarm, and select RRU Fault Analyzer from the shortcut menu.



© ZTE All rights reserved



30



Viewing and Locating an Alarm 



In the Fault Management window of the EMS client, double-click an alarm. The



Alarm Details dialog box is displayed.



© ZTE All rights reserved



31



Viewing and Locating an Alarm 



View historical alarm information about the Active alarm for the reference of alarm handling and analysis. 



In the EMS client window, select Fault>Alarm Monitoring. The Alarm Monitoring window is displayed.







Right-click an alarm. Select Related History Alarms (Position) from the



shortcut menu. The History Alarms page is displayed. 







View the historical alarm information about the alarm.



Locate the physical position of the alarm through the alarm location operation. 



Locate the alarm to the NE: The system automatically opens the Topology Management window, and selects the NE where the alarm is generated.







Locate the alarm to the rack view: The system automatically opens the page where the rack view is located. Maintenance personnel can view the faulty board on the rack view.



© ZTE All rights reserved



32



Manually Forwarding the Alarm



© ZTE All rights reserved



33



Troubleshooting the Alarm & Recording Alarm Handling Suggestions



© ZTE All rights reserved



34



Contents 



Alarm Management Overview







Alarm Management Parameters







Alarm Monitoring







Alarm Data Maintenance



35



Alarm Data Maintenance



© ZTE All rights reserved



36



Manually Synchronizing Alarms 1. In the EMS client, select Fault>Synchronize Active Alarms. The



Synchronize Active Alarms dialog box is displayed. 2. In the navigation tree on the left, select one



or multiple NEs. Click ->. Add them to selected NEs. 3. Click OK.



© ZTE All rights reserved



37



Manually Collecting Statistics on Alarms



© ZTE All rights reserved



38



Basic Alarm Statistics



© ZTE All rights reserved



39



Busy-Time Alarm Statistics



© ZTE All rights reserved



40



Important Alarm Code Statistics



© ZTE All rights reserved



41



Customizing a Statistics Template



© ZTE All rights reserved



42



Creating Query Conditions



© ZTE All rights reserved



43



Copying and Pasting a Query Condition



© ZTE All rights reserved



44



Alarm Statistics Display



Pie chart



Histogram Table © ZTE All rights reserved



45



Managing a Periodical Statistics/Export Task



© ZTE All rights reserved



46



Setting an Automatic Historical Alarm Acknowledgement Task 



In the EMS client, select Maintenance>Task Management>Show Timing Task. The Task Management window is displayed.







In the navigation tree on the left, click Common Task>Alarm Background Task>Automatically Acknowledge



History Alarms Setting. The number of days of the scheduled task and period information are displayed on Click here to edit the right. the number of days



© ZTE All rights reserved



47



Manually Backing up or Restoring Alarm Data 



In the EMS client window, select Maintenance>System Backup and Restore. The Backup and Restoration window is displayed.







In the navigation tree on the left, click Backup and Restore>Backup/Restore>Backup and Deletion Alarm Data. The Configure Parameters of Backup and Deletion page is displayed on the right.



Backup and deletion



Data restoration



© ZTE All rights reserved



48



Exporting or Importing Alarm Handling Suggestions 



In the EMS client window, select Fault>Setting>Handling Suggestions Setting. The Handling Suggestion Setting window is displayed.