4 0 183 KB
Air Cooled Split Type Air Conditioners
Indoor units Ceiling Mounted Cassette Type
Ceiling Mounted Built-in Type
Quiet,decor-blending form and easy installation in new or old buildings. Multiple unit installations maintain a physical uniformity that is aesthetically pleasing and make it easier to plan ceiling lighting systems and to design interiors.
With the use of simple ducts, discharge outlets can be located in a multitude of ways. Top priority given to interior decor, built-in type units realize ideal air current distribution. FH(Y)B
FH(Y)C
Ceiling Suspended Type
Wall Mounted Type Wall mounted type units feature the lowest sound levels in the industry and greatly upgraded comfort, thanks to the high fan speed mode.
On-ceiling installation leaves floor space unhindered. Extremely quiet operation enhances the store's customer service. FH(Y)
FA(Y)
Ceiling Mounted Cassette Corner Type Uni-directional discharge outlet is perfect for corner installation. A thin, 21.5 cm main body enables installation even in a small ceiling overhead space.
Floor Standing Type
Floor standing type units are easy to install and maintain; their slimness is suitable for installation in high-ceiling stores and offices. FHK FV(Y)
Packaged Air Conditioners Duct Connection Series Low static pressure
Middle static pressure
High static pressure
FDMG FDB(G) FDYB
FD(Y)M
FD(Y) For details, please refer to P33-P40.
Outdoor Unit
R emote C ontroller
LCD Wireless LCD Wired Remote Controller Remote Controller
9
10
Air Cooled Split Type Air Conditioners—Specifications (For specifications of duct connection series, please refer to P35-P40.)
C ooling Only (50 Hz) Ceiling mounted cassette type Indoor unit Model
Outdoor unit
Wall mounted type 50
60
71
100
125
FHC50KVE
FHC60KVE
FHC71KVE
FHC100KVE
FHC125KVE
R71FUV1
R100FUV1
R71FUY1
R100FUY1
R60GV1K
R50GV1
Power supply
R125FUY1
VE: 1 phase, 220-240 V/220 V, 50/60 Hz/V1: 1 phase, 220-240 V,50 Hz/Y1: 3 phase, 380-415 V,50 Hz kW RT
1.5/1.5
1.8/1.8
2.2/2.2
3.0/3.0
Cooling capacity
Btu/h
18,200/18,100
22,000/21,800
26,600/26,300
36,200/35,800
44,400/43,700
*1 (1)/(2)
kcal/h
4,590/4,560
5,540/5,500
6,700/6,600
9,100/9,000
11,200/11,000
Power comsumption *1 (1)/(2)
kW
7.80/7.7
10.6/10.5
kW
2.55/2.53
7.8/7.7
10.6/10.5
13.0/12.8
3.69/3.65
4.39/4.35
Power comsumption *1 (1)/(2)
2.87/2.88
2.96/2.94
COP *1 (1)/(2)
3.6/3.56
3.06/3.04
2.94/2.95
°CDB
Operation range (Outdoor temp.)
21 to 52
Floor standing type 50
60
71
100
125
FH50BVE
FH60BVE
FH71BVE
FH100BVE
FH125BVE
R50GV1
R60GV1K
R71FUV1
R100FUV1
R71FUY1
R100FUY1
R125FUY1
RT
1.5/1.4
1.9/1.8
2.2/2.2
3.0/3.0
Btu/h
17,700/17,400
22,500/22,200
26,600/26,300
36,200/35,800
44,400/43,700
kcal/h
4,460/4,400
5,690/5,600
6,700/6,600
9,100/9,000
11,200/11,000
Power comsumption *1 (1)/(2)
44,400/43,700
9,100/9,000
11,200/11,000
kW
13.0/12.8
3.79/3.75
4.67/4.63
Power comsumption *1 (1)/(2)
2.78/2.76
COP *1
13.0/12.8
3.76/3.74
4.49/4.45
2.82/2.81
°CDB
2.9/2.88
21 to 52
•
45
60
FHK45FV1
FHK60FV1
R50GV1
R60GV1K
Power supply
C ooling Only (60 Hz)
1 phase, 220-240 V, 50 Hz RT
1.5/1.4
1.9/1.8
Cooling capacity
Btu/h
17,700/17,400
22,500/22,200
*1 (1)/(2)
kcal/h
4,460/4,400
5,690/5,600
kW
5.19/5.1
6.6/6.5
kW
2.25/2.24
2.76/2.74
Ceiling mounted cassette type
Model
2.39/2.37
2.31/2.28 °CDB
45
60
Indoor unit
FHB45FV1
FHB60FV1
Outdoor unit
R50GV1
R60GV1K
Power supply
50 FHC50KVE
60 FHC60KVE
71 FHC71KVE
100 FHC100KVE
125 FHC125KVE
125 FHYC125KVE
140 FHYC140KVE
R50GVAL
R60GVAL
R71FUVAL
R100FUVAL
R125FUTAL
R125KUYALK
R140KUTALK R140KUYALK
VE: 1 phase, 220-240 V/220 V, 50/60 Hz/VAL: 1 phase, 220 V, 60 Hz/TAL: 3 phase, 220 V, 60 Hz/YAL: 3 phase, 380 V, 60 Hz
RT
1.5/1.4
1.9/1.8
Cooling capacity
Btu/h
17,700/17,400
22,500/22,200
*1 (1)/(2)
kcal/h
4,500/4,400
5,700/5,600
kW
5.19/5.1
6.6/6.5
kW
2.33/2.32
2.78/2.76
2.23/2.20
2.37/2.36
RT
1.6/1.3
1.9/1.6
2.3/1.9
3.2/2.6
Cooling capacity
Btu/h
19,100/15,400
23,200/19,100
27,600/22,900
38,900/30,700
48,800/42,700
48,800/42,700
53,900/47,800
*1 (1)/(2)
kcal/h
4,800/3,900
5,800/4,800
7,000/5,800
9,800/7,700
12,300/10,800
12,300/10,800
13,600/12,000
Power comsumption *1 (1)/(2) Operation range (Outdoor temp.)
4.1/3.6
4.1/3.6
kW
5.6/4.5
6.8/5.6
8.1/6.7
11.4/9.0
14.3/12.5
14.3/12.5
15.8/14.0
2.21/2.5
2.73/3.14
3.34/4.2
4.54/5.80
6.08/7.00
5.50/6.80
5.70/
2.53
2.49
2.43
2.51
2.35
2.60
°CDB
19.4 to 54
2.77
21 to 54
KUTALK.....6.80, KUYALK.....7.10
Ceiling suspended type 50 Model
19.4 to 54
71
100
125
FH50BVE
FH60BVE
FH71BVE
FH100BVE
FH125BVE
R50GVAL
R60GVAL
R71FUVAL
R100FUVAL
R125FUTAL
Power supply
VE: 1 phase, 220-240 V/220 V, 50/60 Hz/VAL: 1 phase, 220 V, 60 Hz/TAL: 3 phase, 220 V, 60 Hz/YAL: 3 phase, 380 V, 60 Hz
RT
1.5/1.3
1.8/1.6
2.3/1.9
3.2/2.6
4.1/3.6
Cooling capacity
Btu/h
17,900/15,400
22,200/19,100
27,600/22,900
38,900/30,700
48,800/42,700
*1 (1)/(2)
kcal/h
4,500/3,900
5,600/4,800
7,000/5,800
9,800/7,700
12,300/10,800
kW
5.25/4.5
6.5/5.6
8.1/6.7
11.4/9.0
14.3/12.5
kW
2.3/2.5
2.84/3.2
3.44/4.2
4.67/5.80
6.25/7.00
2.28
2.29
2.35
2.44
2.29
Conversion rates kcal/h = kW x 860 Btu/h = kW x 3412 RT = kW x 0.284
60
Indoor unit Outdoor unit
Power comsumption *1 (1)/(2) COP *1 (1) Operation range (Outdoor temp.)
•
°CDB
19.4 to 54
21 to 54
Notes : *1:Nominal cooling capacities are based on the following conditions: (1) Return air temperature: 27°CDB, 19.0°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal) (2) Return air temperature: 29°CDB, 19.0°CWB, Outdoor temperature: 46°CDB, 24°CWB Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)
11
4.5/4.0
kW
COP *1 (1)
1 phase, 220-240 V, 50 Hz
Notes : *1:Nominal cooling capacities are based on the following conditions: (1) Return air temperature: 27°CDB, 19.5°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal) (2) Return air temperature: 27°CDB, 19.0°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal)
Indoor unit Outdoor unit
Power supply
19.4 to 54
Ceiling mounted built-in type
°CDB
10.6/10.5
2.67/2.65 2.92/2.91
Notes : *1:Nominal cooling capacities are based on the following conditions: (1) Return air temperature: 27°CDB, 19.5°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal) (2) Return air temperature: 27°CDB, 19.0°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal)
Indoor unit
COP *1 (1)/(2)
7.80/7.7
kW
(1)/(2)
Operation range (Outdoor temp.)
Outdoor unit
COP *1 (1)/(2)
3.7/3.6
36,200/35,800
6,700/6,600
10.6/10.5
Ceiling mounted cassette corner type
Power comsumption *1 (1)/(2)
3.0/3.0
26,600/26,300
7.8/7.7
21 to 52
2.2/2.2
Btu/h
2.58/2.56
2.80/2.80
R125FUY1
kcal/h
6.6/6.5
3.02/3.01
R100FUY1
*1 (1)/(2)
2.8/2.78 2.36/2.34
R71FUY1
Cooling capacity
5.19/5.1
19.4 to 54
125 FV125LAVE
R100FUV1
RT
3.7/3.6
2.16/2.15 2.40/2.37
100 FV100LAVE
R71FUV1
VE: 1 phase, 220-240 V/220 V, 50/60 Hz/V1: 1 phase, 220-240 V, 50 Hz/Y1: 3 phase, 380-415 V, 50 Hz
kW °CDB
71 FV71LAVE
Outdoor unit
Power supply
kW COP *1 (1)/(2) Operation range (Outdoor temp.)
Indoor unit Model
*1 (1)/(2)
•
9,100/9,000
3.00/2.98
VE: 1 phase, 220-240 V/220 V, 50/60 Hz/V1: 1 phase, 220-240 V, 50 Hz/Y1: 3 phase, 380-415 V, 50 Hz
Operation range (Outdoor temp.)
36,200/35,800
6,700/6,600
2.60/2.58
Outdoor unit
Power comsumption *1 (1)/(2)
26,600/26,300
kcal/h
6.44/6.4
Cooling capacity
Model
3.0/3.0
Btu/h
*1 (1)/(2)
2.63/2.62
Power supply
Operation range (Outdoor temp.)
R100FUY1
Cooling capacity
2.45/2.44
Indoor unit
Model
R71FUY1 2.2/2.2
5.34/5.3
21 to 52
R100FUV1
VE: 1 phase, 220-240 V/220 V, 50/60 Hz/V1: 1 phase, 220-240 V, 50 Hz/Y1: 3 phase, 380-415 V, 50 Hz
2.64/2.64 19.4 to 54
100 FA100FVEK
R71FUV1
RT
2.02/2.01
Ceiling suspended type
Model
Power supply
3.7/3.6
kW °CDB
71 FA71FVEK
Outdoor unit
kW COP *1 (1)/(2) Operation range (Outdoor temp.)
Indoor unit Model
Conversion rates kcal/h = kW x 860 Btu/h = kW x 3412 RT = kW x 0.284