HEATLESS DESICCANT COMPRESSED AIR DRYER
MODELS SSD 100 - 3000 INSTALLATION, OPERATION & MAINTENANCE MANUAL
Service Department 1-800-SULLAIR Option: 1454
MANUAL PART # 02250182-666 REV.1
1625
E Second St,
Michigan City, IN
46360
•
PH:
888-SULLAIR
•
Fax:
219-878-4206
CONTENTS 1.
Installation and Inspection .............. 4
12. Desiccant Replacement ................ 12
25. Maintenance Log .......................... 51
2.
Safety and System Precautions ..... 5
13. Inlet and Exhaust Valve Repair ..... 12
26. Purge Orifice Chart……………..52
3.
General Operation .......................... 6
4.
Sequence of Operation .............. 6 - 8 - Diagram
14. Parts .............................................. 13 - General Parts Description - Recommended Spare Parts
5.
Start Up .......................................... 8
6.
Operation Notes ........................ 8 - 9 - Variable Cycle Control - Cycle Timing
7.
Shutdown Procedure ...................... 9 - Isolation - Depressurization
8.
What are “Demand Cycles?” ... 9 - 10
9.
Purge Flow ............................. 10 - 11
10. Dryer Capacity .............................. 11 11. Maintenance Program .................. 11 - Daily - Weekly - Semi-Annually - Annually
27. Powersaver Plus Probe Specs.53
15. Flow Diagram & Parts List..14-31 - SSD100 to SSD3000 16. Troubleshooting ..................... 32 - 33 17. Wiring Diagram .................... 34 - 44 - SSD100 to SSD3000 - Power Saver Plus - Power Saver 19. Timing Charts ........................ 45- 46
20. Analyzing Chart ............................ 47 21. Power Saver Plus System .... 48 - 50
3
Dryer Outlet Flow Dryer outlet flow is equal to the dryer inlet flow minus the purge flow.
Sizing is approximate only. Consult factory for exact sizing. Downsizing could cause pressure drop, bed fluidization, or poor dew point performance due to low contact time. The previous chart assumes 100°F or less inlet air temperature.
10. DRYER CAPACITY
11. MAINTENANCE PROGRAM
Checking Dryer Size: A. Determine operating pressure.
Daily
B. Determine input SCFM into dryer.
1. Check dew point or humidity level if instrumentation is available. Any difficulty with the dryer will result in poor dew point performance.
Read down the nearest operating pressure column until you arrive at a rating equal to or greater than your equipment; then read to the left for dryer model. PRESSURE
2. Check for correct purge setting and air flow from purge exhaust. 3. Check gauge readings and sequence of operation through complete cycle.
MODEL
60
80
100
120
140
SSD-100
70
88
107
126
144
SSD-160
88
111
135
159
182
4. Check auto drain operation on pre-filter, separator and receiver. A manual drain valve installed (in addition to the automatic drain) at these points will ease checking of the automatic drains.
SSD-220
130
165
200
235
270
5. Ensure there is no back pressure in the regenerating tower.
SSD-300
195
248
300
352
405
Weekly
SSD-400
261
330
400
470
540
1. Check differential pressure across pre-filter and afterfilter elements. Replace if required.
SSD-500
332
421
510
599
688
SSD-600
423
537
650
780
877
SSD-750
521
661
800
940
1079
SSD-1050
651
826
1000
1175
1359
SSD-1450
975
1239
1500
1762
2024
SSD-2000
1303
1652
2000
2350
2698
SSD-2500
1694
2147
2600
3054
3508
SSD-3000
1954
2478
3000
3524
4048
EXAMPLE: You want to dry 95 SCFM at 80 PSIG - go to the 80 PSIG column and read down to 111 (this is the first number equal to, or greater than your requirement). Now read the dryer model number to you left. A model SSD-160 is required.
2. Check and maintain operating conditions; pressure, flow, and temperature within the design parameters of the dryer.
Semi-Annually 1. Inspect desiccant for physical condition. Desiccant from a freshly regenerated bed should be white, dry to touch and of consistent size and shape. If desiccant condition is in question, send a sample to SULLAIR for analysis. 2. Check and clean mufflers. This may be required often under certain conditions or if back pressure develops. Mufflers can be cleaned by blowing backwards through them with clean, dry air. Mufflers may require replacement if severely clogged, or after a few cleanings. 3. Inspect pre-filter and afterfilter elements. 4. Clean automatic drain. 5. Replace Control Air Filter Element. 6. Check and Slowdown Safety Valves. Refer to manufacturer’s instructions. 7. Clean dryer.
Annually 1. Inspect Inlet and Exhaust Valves (rebuild as needed). 2. Clean Control Solenoid Valves.