6 0 1 MB
Huawei XL LTE 1800 MHz SOP Implementation
www.huawei.com www.huawei.com
Software version SRAN9.0
NE Name
NE Count Target Version (R&D)
BSC6900 GO
BSC6900V900R016C00SPC620
BSC6900 UO
BSC6900V900R016C00SPC620
BTS3900A_GSM
BTS3900 V100R009C00SPC186
BTS3900L_GSM
BTS3900 V100R009C00SPC186
M2000
V200R014C00SPC210
CME
V200R014C00SPC210
Huawei Confidential
Page 2
On Site Operation Process On site Team : 1. Insert UMPT or replace GTMU with UMPT 2. Insert UBBP slot 3 for GSM only, and slot 2 if WBBP exist in slot 3 3. Upgrade cabinet to Ver. D if scenario using MRFUd, then continue install MRFUd 1800 Mhz 4. Install RRU 3939 if scenario using RRU 5. Reroute CPRI connection based on scenario implementation 6. Cut over transmission to UMPT and new port on RTN/MSTP 7. Download BTS3900 V100R009C00SPCXXX to UMPT (25 minutes) 8. Activate software (10 minutes) 9. SPL software (5 minutes) 10. Download script 11. Activate script 12. Inform to monitoring team whether OM has been Ok or not 13. Dismantle unused materials Monitoring Team : 1. Delete original NE GBTS , Then synchronize NE on U2000 2. Activate eGBTS license dan eNodeB license 3. If existing has 3G, ask RTN/TRM team to reroute IuB vlan service Huawei Confidential
Page 3
Download software to UMPT (20 menit) Make sure SFTP is running. Double click application below :
Setting IP Laptop: 192.168.0.50 (or 17.21.2.XX) Login via Internet Explorer : IP : 192.168.0.49 (or 17.21.2.15) User name : admin Password : hwbs@com (or NodeB)
Huawei Confidential
Page 4
Download software to UMPT (25 minutes) DLD SOFTWARE: MODE=IPV4, IP="192.168.0.50", USR="admin", PWD="*****", DIR="D:\BTS3900 V100R009C00SPC170_ALL(Software)", SWT=SOFTWARE, SV="D:\BTS3900V100R009C00SPC170", DC=NO, ATL=GBTS&NodeB;
FTP Server IP = IP Laptop Directory Name : address where we save the software Huawei Confidential
Page 5
Activate Software (10 minutes) ACT SOFTWARE: OT=NE, SWT=SOFTWARE, SV="BTS3900V100R009C00SPC170", ATL=GBTS&NodeB;
Huawei Confidential
Page 6
SPL Software (5 Minutes) SPL SOFTWARE: MODE=IPV4, IP="192.168.0.50", USR="admin", PWD="*****", DIR="D:\BTS3900 V100R009C00SPC170_ALL(Software)", SDL=YES;
Verify SPL software : Run MML command DSP GLOCELL If the MML is not appear, it means SPL software has not succeed
Huawei Confidential
Page 7
Software Verification DSP APP:;
Huawei Confidential
Page 8
Download script DLD CFGFILE: IP="192.168.20.48", USR="admin", PWD="*****", DIR="E:\compt", FN="E720G_3G_KESAWAN_FullExport_20141124022032";
Huawei Confidential
Page 9
Activate script ACT CFGFILE: EFT=AFTER_RESET;
Then Reset UMPT board (From LMT / plug-unplug)
Huawei Confidential
Page 10
Check Software Version and Cell Service • LST VER :; • DSP APP:; • DSP LICENSE: FUNCTIONTYPE=GBTS; • DSP LICENSE: FUNCTIONTYPE=NodeB; • DSP LICINFO:; • CHK DATA2LIC:; • LST ULOCELL: MODE=ALLLOCALCELL; //3G Cell • DSP GLOCELL:; //2G Cell • DSP CELL:; //LTE Cell • Monitor Channel Status and Traffic Huawei Confidential
Page 11
BBU Solution GSM Only Before
After - ADD UMPTb1 (slot 7) - ADD UBBPd3 (Slot 3) - ADD UBRI (Optional)
Huawei Confidential
Page 12
BBU Solution GU Co-Cabinet Before
After
- ADD UMPTb1 (slot 7) - Move WBBP slot 2 to slot 4 - ADD UBBPd3 (Slot 2) - ADD UBRI (Optional)
Huawei Confidential
Page 13
RF Solution
Huawei Confidential
Page 14
Scenario 1: Existing site is G900 only
Existing : - 3 MRFU V2 900MHz - BBU Box : GTMU BEFORE
Solution : - Keep GTMU - Add DCDU-12B + 3 RRU 3939 (LO) - Add UMPTb1 (LTE Only) slot 7 - Add UBBPd6 slot 3
Huawei Confidential
Page 15
Scenario 1: Existing site is G900 only
Existing : - 3 MRFU V2 900MHz - BBU Box : GTMU AFTER
Solution : - Keep GTMU - Add DCDU-12B + 3 RRU 3939 (LO) - Add UMPTb1 (LTE Only) slot 7 - Add UBBPd6 slot 3
Huawei Confidential
Page 16
Scenario 2: Existing site is D1800 only
Existing : - 3 MRFU V2 1800MHz or RRU 3926 V3 - BBU Box : GTMU BEFORE
Solution : - Add DCDU-12B + 3 RRU 3939 (GL SDR) / MRUFd 1800 - Add UMPTb1 GL co-MPT slot 7 - Add UBBPd3 to slot 3 -Dismantle RRU 3926 / MRFU V2 1800 -Dismantle GTMU -CPRI MUX from UBBPd3 to RRU 3939
Huawei Confidential
Page 17
Scenario 2: Existing site is D1800 only
Existing : - 3 MRFU V2 1800MHz or RRU 3926 V3 - BBU Box : GTMU AFTER
Solution : - Add DCDU-12B + 3 RRU 3939 (GL SDR) / MRUFd 1800 - Add UMPTb1 GL co-MPT slot 7 - Add UBBPd3 to slot 3 -Dismantle RRU 3926 / MRFU V2 1800 -Dismantle GTMU -CPRI MUX from UBBPd3 to RRU 3939
Huawei Confidential
Page 18
Scenario 3: Existing site is G900 + D1800 Existing : -3 MRFU V2 900MHz + 3 MRFU V2 1800MHz -BBU Box : GTMU BEFORE
Solution : - Add DCDU-12B + 3 RRU 3939 (GL) - Add UMPTb1 GL co-MPT slot 7 - Add UBBPd3 to slot 3 -dismantle MRFU V2 OL1 -Keep GTMU for UL interface only -CPRI MUX from UBBPd3 to RRU 3939
Huawei Confidential
Page 19
Scenario 3: Existing site is G900 + D1800 Existing : -3 MRFU V2 900MHz + 3 MRFU V2 1800MHz -BBU Box : GTMU AFTER
Solution : - Add DCDU-12B + 3 RRU 3939 (GL) - Add UMPTb1 GL co-MPT slot 7 - Add UBBPd3 to slot 3 -dismantle MRFU V2 OL1 -Keep GTMU for UL interface only -CPRI MUX from UBBPd3 to RRU 3939
Huawei Confidential
Page 20
Scenario 4: Existing site is G900 + U2100 Existing : -3 MRFU V2 900MHz + 3 WRFU / RRU 3839 -BBU Box : GTMU , WMPT , WBBP (slot 1-2-3) BEFORE
Solution : - Add DCDU-12B + 3 RRU 3939 - Replace GTMU with UMPTb1 (GL co-MPT) slot 6 - Move existing WBBP slot 2 to slot 4 -Insert UBBPd3 in slot 2 - dismantle GTMU
Huawei Confidential
Page 21
Scenario 4: Existing site is G900 + U2100 Existing : -3 MRFU V2 900MHz + 3 WRFU / RRU 3839 -BBU Box : GTMU , WMPT , WBBP (slot 1-2-3) AFTER
Solution : - Add DCDU-12B + 3 RRU 3939 - Replace GTMU with UMPTb1 (GL co-MPT) slot 6 - Move existing WBBP slot 2 to slot 4 -Insert UBBPd3 in slot 2 - dismantle GTMU
Huawei Confidential
Page 22
Scenario 5: Existing site is D1800 + U2100 Existing : -3 MRFU V2 1800MHz + 3 WRFU / RRU 3839 -BBU Box : GTMU , WMPT , WBBP (slot 1-2-3) - BTS3900A Cabinet ver.B BEFORE
Solution: - Swap cabinet to Ver.D - Replace MRFU V2 to MRFUd 1800 (GL SDR) - Replace GTMU to UMPTb1 (GL co-MPT) slot 6 - Move existing WBBP slot 2 to slot 4 -Add UBBPd3 to slot 2 -CPRI MUX from UBBPd3 to MRFUd 1800 -Dismantle GTMU - dismantle old cabinet OL1
Huawei Confidential
Page 23
Scenario 5: Existing site is D1800 + U2100 Existing : -3 MRFU V2 1800MHz + 3 WRFU / RRU 3839 -BBU Box : GTMU , WMPT , WBBP (slot 1-2-3) - BTS3900A Cabinet ver.B AFTER
Solution: - Swap cabinet to Ver.D - Replace MRFU V2 to MRFUd 1800 (GL SDR) - Replace GTMU to UMPTb1 (GL co-MPT) slot 6 - Move existing WBBP slot 2 to slot 4 -Add UBBPd3 to slot 2 -CPRI MUX from UBBPd3 to MRFUd 1800 -Dismantle GTMU - dismantle old cabinet OL1
Huawei Confidential
Page 24
HISILICON SEMICONDUCTOR