I K A R A H M A W AT I



HIGH RISE BUILDING



AG E N DA INTRODUCTION REGULATION STAGE OF WORK MEP SYSTEM GREENSHIP



1995 SD Bunulrejo 6 Malang



2007 Universitas Brawijaya Jurusan Arsitektur 2012 Greenship Accociates 2013 Prasetiya Mulya Business School 2014 Greenship Profesional



2008 Boerawa Farm & custom order konveksi 2012 Staff Pengembangan PTPP 2014 Architect Engineer PPRO Grand Kamala Lagoon 2015 Business Development Officer PPRO 2017 Engineering Manager PPRO Begawan 2019 Construction Manager PPRO Begawan 2021 Head of Design Development Department PPRO



HIGH RISE BUILDING



IKA RAHMAWATI MALANG 1989



2004 SMAN 4 Malang



2022 KHARRSA Farm



3



HELLO!



2001 SMPN 5 Malang



4



STAGE OF WORK



HIGH RISE BUILDING



HIGH RISE BUILDING



5



1. Permen PU 29/2006 Pedoman Persyaratan Teknis Bangunan Gedung. 2. Permen PU 05/2007 Pedoman Teknis Pembangunan Rumah Susun Sederhana Bertingkat Tinggi. 3. Permen PU 25/2007 Pedoman Sertifikat Laik Fungsi Bangunan Gedung. 4. Permen PU 24/2008 Pedoman Pemeliharaan dan Perawatan Bangunan Gedung. 5. Permen PU 25/2008 Pedoman Teknis Penyusunan Rencana Induk Sistem Proteksi Kebakaran. 6. Permen PU 26/2008 Persyaratan Teknis Sistem Proteksi Kebakaran Pada Bangunan dan Lingkungan. 7. Permen PU 20/2009 Pedoman Teknis Manajemen Proteksi Kebakaran Di Perkotaan. 8. Permen PU 16/2010 Pedoman Teknis Pemeriksaan Berkala Bangunan Gedung. 9. Permen PU 17/2010 Pedoman Teknis Pendataan Bangunan Gedung. 10.Permen PU 18/2010 Pedoman Revitalisasi Kawasan. 11.Permen PU 11/2014 Pengelolaan Air Hujan pada Bangunan Gedung dan Persilnya. 12.Permen PUPR 01/2015 Bangunan Gedung Cagar Budaya yang Dilestarikan. 13.Permen PUPR 02/2015 Bangunan Gedung Hijau. 14.Permen PUPR 06/2017 Perubahan Atas Peraturan Menteri Pekerjaan Umum Dan Perumahan Rakyat Nomor: 05/PRT/M/2016 Tentang Izin Mendirikan Bangunan Gedung. 15.Permen PUPR 14/2017 Persyaratan Kemudahan Bangunan Gedung 16.SE Menteri PUPR Nomor 10/SE/M/2016 Penerbitan Izin Mendirikan Bangunan Gedung dan Sertifikat Laik Fungsi Bangunan Gedung untuk Bangunan Gedung Usaha Menegah Kecil dan Mikro Seluas 1.300 M2 dengan Menggunakan Desain Prototipe. 17.SE Direktur Jenderal Cipta Karya Kementerian PUPR nomor 86/SE/DC/2016 tanggal 29 Desember 2016 tentang Petunjuk Teknis Penyelenggaraan Bangunan Gedung Hijau.



HIGH RISE BUILDING : MEP



R E G U L AT I O N



O RG A N I Z AT I O NA L S T RU C T U R E Pemilik Proyek



Arsitektur



Pelaksana Arsitektur



Pengawas



SKRK



Arsitektur



Struktur



Struktur



Struktur



MEP



MEP



MEP



Infrastruktur



Infrastruktur



Infrastruktur



Ijin Lingkungan AMDAL ANDALALIN KKOP



TABG IMB



Lansekap



Lansekap



Lansekap



SLF Interior



HIGH RISE BUILDING : MEP



Perencana



6



QS



HIGH RISE BUILDING



7



HIGH RISE BUILDING : MEP



MECHANICAL ELECTRICAL & PLUMBING



Listrik : • Gardu • Genset • Ruang Panel • MCB • Wiring • Titik Lampu • Elektronik • Stop Contact • Saklar



CCTV : • Sistem • Kapasitas simpan • Posisi • Wiring



Tata Udara : • In Take • Out Put • Power • Ducting



8



Plumbing : • Air Bersih • Air Kotor • Air Dapur • Air Buangan • Air Hujan • Air AC • Pipeline



HIGH RISE BUILDING : MEP



ANALOGI



MECHANICAL ELECTRICAL



Pekerjaan Plumbing Meliputi : 1. Air Bersih 2. Air Kotor 3. Air Dapur 4. Air Buangan 5. Air Hujan 6. Air AC



9



Pekerjaan Elektrikal Meliputi : 1. Pekerjaan Arus Kuat Genset, Panel, Instalasi Penerangan, Stop Kontak, Rak Kabel & Support, Lightning Protection & Grounding 2. Pekerjaan Arus Lemah : a. Fire alarm b.Sound System c. Telephone / data system d.CCTV e. MATV f. BAS (Building Automatic System) g.IT System



HIGH RISE BUILDING : MEP



Pekerjaan Mekanikal Meliputi : 1. Pekerjaan HVAC 2. Pekerjaan Fire Fighting 3. Pekerjaan Elevator, Escalator dan Gondola



10



HIGH RISE BUILDING : MEP



MECHANICAL



ELECTRICAL



EFFICIENCY



SAFETY



MAINTENANCE



11



SUFFICIENCY



HIGH RISE BUILDING : MEP



FUNDAMENTAL



STAGE OF WORK



Test Parsial



Pemasangan Material Utama



Testing Commissioning



Finish



12



Pekerjaan Instalasi



HIGH RISE BUILDING : MEP



Start



HIGH RISE BUILDING



13



HIGH RISE BUILDING : MEP



MECHANICAL ELECTRICAL



MECHANICAL ELECTRICAL SYSTEM SISTEM LISTRIK ARUS KUAT



PLN Photovoltaic Cell



Inverter Panel



LVMDB 1



KE PANEL DISTRIBUSI



Genset n x ……KVA



Control Panel Genset



HIGH RISE BUILDING : MEP



KE PANEL DISTRIBUSI



Trafo…….KVA



14



MVMDB



MECHANICAL ELECTRICAL SYSTEM SISTEM LISTRIK ARUS KUAT busduct



PP



PP Chiller LT. ATAP



PP



PP AHU



LP PP



LT. n



PP AHU



LP PP



PP AHU



LP PP



PP AHU



LP PP



PP AHU



LP PP



LT. 3



PP AHU



LP



LT. 2



PP



PP AHU



LP MVDM GARDU PLN



LT. DASAR …..… kVA …..KV/3Φ/50Hz



PP AC



Genset n x……. kVA Control Panel ……..RPM 50 Hz 3Φ Genset Stand By Power



HIGH RISE BUILDING : MEP



PP AHU



LP PP



LVDP



TRAFO



MCC



BASEMENT



15



MVDP : Medium Voltage Distribution Panel LVDP : Low Voltage Distribution Panel PP : Power Panel LP : Lighting Panel MCC : Motor Control Centre



MECHANICAL ELECTRICAL SYSTEM



16



HIGH RISE BUILDING : MEP



INSTALASI PENERANGAN, KABEL, SAKLAR, & STOP KONTAK



MECHANICAL ELECTRICAL SYSTEM



17



Tampak atas



HIGH RISE BUILDING : MEP



INSTALASI PENERANGAN, KABEL, SAKLAR, & STOP KONTAK



MECHANICAL ELECTRICAL SYSTEM INSTALASI PENERANGAN, KABEL, SAKLAR, & STOP KONTAK



MECHANICAL ELECTRICAL SYSTEM SISTEM HVAC



Central Air Conditioning System



Split Wall Air Conditioning



Condensing Water Pump



Chilled Water Pump Supply Cooling coil in AHU Outdoor Unit



Cooling Tower



Water Cooled Chiller Chilled Water Pump Return



Pipa Refrigerant



Exhaust Fan



Ventilating System



Indoor Unit return ducting to supply area



Ruangan yang didinginkan



AHU



Conditione d Space



MECHANICAL ELECTRICAL SYSTEM SISTEM HVAC CENTRAL AIR Roof



AHU Floor



AHU



Cooling Condenser Tower Water Pump



WMP



Make Up Water Tank



CHILLER



Chilled Chilled Water Water Pump Pump Secondary Primer



Ground Floor



Basement



MECHANICAL ELECTRICAL SYSTEM SISTEM ELEVATOR



Service elevator/Cargo elevator Kap. : 1500 kg Door opening : sesuai gambar Speed : 90 mpm Control sistem : AC single speed Traveling : …….. M Lantai : lantai …….. Passenger elevator/penumpang Kap. : 1000 kg Door opening : 2 step / 2 opening Speed : 60 mpm Control sistem : AC single speed Traveling : …….. M Lantai : lantai ……..



21



Passenger elevator/penumpang Kap. : 15 orang / 1150 kg Door opening : sesuai gambar Speed : 105 mpm Control sistem : VVVF computerized Traveling : …….. M Lantai : lantai ……..



HIGH RISE BUILDING : MEP



Contoh Schedule Elevator



MECHANICAL ELECTRICAL SYSTEM SISTEM ELEVATOR



Code



PASSENGER ELEVATOR



LF-PH1



LF-PK 1



LF-PH1



Lantai 1-n



Lantai 1 - n



Lantai 1-n



1



1



1



1000 ( 15 )



1000 ( 15 )



1000 ( 15 )



90



90



90



900 mm (Center opening)



800 mm (Center opening)



900 mm (Center opening)



2100



2100



2100



Hoistway (mm)



2000 (W) x 2100 (D)



2350 (W) x 2900 (D)



2000 (W) x 2100 (D)



Car Size (mm)



1600 (W) x 1500 (D)



1500 (W) x 2300 (D)



1600 (W) x 1500 (D)



Pit Depth (mm)



1600



1600



1600



Machine Room



At the top of the Lift Shaft



At the top of the Lift Shaft



At the top of the Lift Shaft



4750



4750



4750



Service of Floor Unit Capacity kg (person) Speed (mpm) Door Opening (mm) Entrance Height (mm)



Lantai 3 Lantai 2 Lantai 1 Basement SERVICE ELEVATOR



BED ELEVATOR



PESSENGER ELEVATOR



Over Head (mm)



HIGH RISE BUILDING : MEP



Lantai n



BED ELEVATOR



22



SERVICE ELEVATOR



MECHANICAL ELECTRICAL SYSTEM SISTEM FIRE ALARM ROOF



JB-FA.CB



B X



JB-FA



MM MM



P



P



`



S



B



MM MM



B



X



MM



F S



X



HIGH ZONE JB-FA.CB MM MM



S



P



P B



MM MM



X



MM



Lt n



B F S



X



AMENITY JB-FA.CB MM MM



S



P



P B



MM MM



B



X



MM



F S



X



LOW ZONE ANNUNCIATOR (1X)



JB-FA.CB MM



MAINTENANCE SYSTEM



MM



ONE WAY VOICE COMMUNICATION



S



P



B



MM MM



X



MM



REPORT SLIP PRINTER



MCP-FA



P B F S



X



Lt Dasar LOBBY



MDF-FA JB-FA.CB MM



TO CENTRAL SS (SIREN)



MM



TO PABX (AUDODIAL



MM MM MM



S



P



P B X



B X



F S



HIGH RISE BUILDING : MEP



S



P



: Main Distribution Frame Fire Alarm : Master Control Panel Fire Alarm : Smoke Detector : Manual Push Button : Rate of Rise Detector Heat Detector : Indicator Bell Alarm : Indicator Lamp Alarm : Junction Box Fire Alarm



BASEMENT



R. Kontrol



23



MDF-FA MCP-FA



MECHANICAL ELECTRICAL SYSTEM SISTEM CCTV To MC CCTV BSH



CCTV Digital Video Controller



C



5 C C



C C C C C C



MPEG4 Realtime Encoder



C



MPEG4 Realtime Encoder



Room 1.01



3



DVR 16-2



2



Camera ROOF FLOOR



Camera



Coaxial Cable CCTV Digital Porter Video Controller GF Room Access Control Controller CCTV Digital Coaxial Cable Video Controller Security Room



Camera47 85 96 FLOOR



123



Access Control Coaxial Cable Controller Camera CCTV Digital CCTV Digital Reception Video Controller Room VideoGF Controller



VM



Coaxial Cable



KEYBOARD



DVR 16-3



FIRST FLOOR



Access Control Controller keterangan:



1. 2. 3. 4. 5.



Camera14 25 63



Access Control Controller Coaxial Cable



789



Enter Menu Cancel



1 2 3 Enter 4 5 6 Menu 7 8 9 Cancel



GROUND FLOOR



MONITOR



4



Enter Menu Cancel



Access Control Controller



1 2 3 Enter 4 5 6 Menu 7 8 9 Cancel



MC CCTV= Master Control CCTV. VM = Video Manager. DVR = Digital Video Recorder. TB = Terminal Block. C = Camera.



1 2 3 Enter 4 5 6 Menu 7 8 9 Cancel



HIGH RISE BUILDING : MEP



1



24



CCTV Diagram



MECHANICAL ELECTRICAL SYSTEM



: Outlet TV M



: Modulator



AC



: Active Combiner : Spliter



B



: Booster



R



: Receiver



I



: Input LD/VCD



25



KETERANGAN :



HIGH RISE BUILDING : MEP



SISTEM MATV



MECHANICAL ELECTRICAL SYSTEM BUILDING AUTOMATION SYSTEM DIAGRAM



DDC Telepon Alert



Alarm



Security System Power System Air Handling Unit Chiller



Chilled Water + Lighting Timer



HIGH RISE BUILDING : MEP



PC



SMS



26



MICRO CONTROLLER



MCU



HIGH RISE BUILDING



27



HIGH RISE BUILDING : MEP



PLUMBING



PLUMBING SYSTEM



RT TANGKI ATAS … @ …m3



POMPA HOT WATER



Roof



• •



Toilet, Bathroom dan Kitchen



Toilet, Bathroom dan Kitchen



Toilet, Bathroom dan Kitchen



Toilet, Bathroom dan Kitchen



Toilet, Bathroom dan Kitchen



Toilet, Bathroom dan Kitchen



Lt 4



Toilet, Bathroom dan Kitchen



Toilet, Bathroom dan Kitchen



Lt 3



Toilet, Bathroom dan Kitchen



Toilet, Bathroom dan Kitchen



Lt 2



Toilet, Bathroom dan Kitchen



Toilet, Bathroom dan Kitchen



Lt 1



Toilet, Bathroom dan Kitchen



Toilet, Bathroom dan Kitchen



Lt n



TAMAN



Basement Deep Well Pump



Water Treatment Pump Ground Water Tank : … m3











TAMAN



Sand Filter



Carbon Filter



Ke Roof Tank



Raw Water Tank : … m3



dari PDAM



Sumber air bersih utama diambil dari PDAM. Air bersih dari PDAM ditampung di raw water tank, kemudian dengan menggunakan pompa dan filter di alirkan ke bak penampungan air bersih utama (Ground Water Tank). Air dari tangki bawah (Ground Water Tank Air Bersih) akan dipompakan ke roof tank masing masing tower terlebih dahulu kemudian di distribusikan ke pemakai secara grafitasi, dan pada 4 (empat) lantai dari tempat roof tank berada dilayani dengan menggunakan pompa booster, selanjutnya untuk lantai ke 5 (lima) dari dudukan tanki sampai dengan lantai terbawah pendistribusian air bersih dilakukan secara grafitasi. Untuk mengurangi tekanan air yang berada di pipa tegak air bersih pada sistem gravitrasi; dipasanglah pressure reducing valve (PRV-set) untuk setiap 5 lantai (tekanan air yang dipersaratkan yaitu 1,2-3,5 kg/cm2).



SKEMATIK AIR BERSIH : Pipa Air Panas : Pipa Air Bersih



28



SOLAR WATER HEATER



HIGH RISE BUILDING : MEP



SISTEM AIR BERSIH



PLUMBING SYSTEM SISTEM AIR KOTOR



Toilet, Bathroom dan Kitchen



Toilet, Bathroom dan Kitchen



Toilet, Bathroom dan Kitchen



Toilet, Bathroom dan Kitchen



Toilet, Bathroom dan Kitchen



Lt 4



Toilet, Bathroom dan Kitchen



Toilet, Bathroom dan Kitchen



Lt 3



Toilet, Bathroom dan Kitchen



Toilet, Bathroom dan Kitchen



Lt 2



Toilet, Bathroom dan Kitchen



Toilet, Bathroom dan Kitchen



Toilet, Bathroom dan Kitchen



Toilet, Bathroom dan Kitchen



Lt 1















Sumber air kotoran dan air kotor yaitu dari buangan fixture unit alat plambing apartemen. Air kotoran dari dari unit kamar mandi apartemen di alirkan secara grafitasi menuju ke induk pengolahan air limbah (STP) yang berada di lantai basemen-2. Untuk air kotoran dari unit kamar mandi apartemen yang tidak bisa dilairkan secara grafitasi terlebih dahulu dialirkan ke sewage pit, dan dengan menggunakan pompa kemudian baru dialirkan ke induk pengolahan air limbah (STP) SKEMATIK AIR KOTOR



Ke Saluran Kota STP Kap: … m3



Basement



Tangki Penampung Sementara Kap. … m3



: Pipa Air Kotor : Pipa Air Bekas : Pipa Vent : Pipa Air Hujan



STP Kap: … m3 FT FT STP RWT Kap: … m3 Sump – Pit



RWT FT



: Sewage Treatment Plant : Raw Water Tank : Filter Tank



29



Toilet, Bathroom dan Kitchen



Lt n



HIGH RISE BUILDING : MEP



ROOF DRAIN



Roof



PLUMBING SYSTEM PIPELINE PROBLEM



BALOK MELINTANG



HIGH RISE BUILDING : MEP



2.6m



30



2.4m



PLUMBING SYSTEM



31



BOCOR MELUAP BERISIK



HIGH RISE BUILDING : MEP



ACCESSORIES THAT MATTERS



HIGH RISE BUILDING



32



HIGH RISE BUILDING : MEP



GREENSHIP



EFFICIENCY



SAFETY



MAINTENANCE



33



RENEWABLE



HIGH RISE BUILDING : MEP



FUNDAMENTAL



PLATINUM GOLD SILVER BRONZE



86 67 54 41



34



• Tepat Guna Lahan (Appropriate Site Development-ASD) • Efisiensi dan Konservasi Energi (Energy Efficiency and Conservation-EEC) • Konservasi Air (Water Conservation-WAC) • Sumber dan Siklus Material (Material Resources and Cycle-MRC) • Kesehatan dan Kenyamanan dalam Ruang (Indoor Health and Comfort-IHC) • Manajemen Lingkungan Bangunan (Building Environment Management-BEM)



HIGH RISE BUILDING : MEP



KRITERIA DAN POIN



35



HIGH RISE BUILDING : MEP



KRITERIA DAN POIN



36



HIGH RISE BUILDING : MEP



KRITERIA DAN POIN



37



HIGH RISE BUILDING : MEP



KRITERIA DAN POIN



38



HIGH RISE BUILDING : MEP



KRITERIA DAN POIN



39



HIGH RISE BUILDING : MEP



KRITERIA DAN POIN



40



HIGH RISE BUILDING : MEP



KRITERIA DAN POIN



[email protected]



HIGH RISE BUILDING : MEP



Ika Rahmawati



41