This manual is the property of Hyundai Elevator Co., Ltd and is loaned subject to return upon demand. Contents of this publication shall not be reproduced in any form without written permission of Hyundai Elevator Co., Ltd.



THE EL



Door Controller Operating Manual



Rev. Date Page



0.0 2010.11.11 1 / 12



Door Controller Operating Manual



R&D institute



VOLUME 1.



A4 (210X297 mm)



THE EL



Door Controller Operating Manual



Rev. Date Page



0.0 2010.11.11 2 / 12



Contents



1. Specification



--------------------------------------------- 3



2. System Diagram



---------------------------------------------



3. External Connectors 4. HHT Operation



3



------------------------------------ 4



-------------------------------------------- 5



4.1 HHT Display & Key 4.2 HHT Menu diagram



5. Calibration



------------------------------------------------ 6



5.1 Data 5.1.1 Monitor/01_BASIC MENU 5.1.2 Monitor/03_ERROR MENU 5.1.3 Program/01_CONTROL MENU 5.1.4 Interface Menu 5.1.5 Factory Menu



R&D institute



VOLUME 1.



A4 (210X297 mm)



THE EL



Rev. Date Page



Door Controller Operating Manual



0.0 2010.11.11 3 / 12



1. Specification Part Input supply Applicable motor



HIDC.INT7I.UM



HIDC.INT7I.UH



Single Phase AC 220 V ±15% / 60 Hz ±5% (Input Voltage lines must not connect to frame ground ) 3Φ AC220V, 400 W, 4P, 1.9 A



3Φ AC220V, 750 W, 4P, 3.8 A



Applicable encoder



2500 ppr, Line Drive, 5Vdc



Control type



Sensored Vector Control



Switching Frequency



10 KHz



Ambient Temperature



.10 ℃ to +40 ℃



Storage Temperature



.20 ℃ to +60 ℃



Ambient Humidity



20 ~ 90% RH (Non.condensation)



Input Signals



Open/Close signals(OP, CL, NUD), Limit signals(OPL, CLL), Control signal( RST ), Encoder signals(A,/A,B,/B)



Output Signals



OPL, CLL, CLS, 30B, LDT



Protective Function



Under Voltage, Over Voltage, Over Current, Over Load, Encoder Error, IPM Fault, Inverter Over Temperature, Over Speed



2. System Diagram



Figure 1 Door inverter main board



R&D institute



VOLUME 1.



A4 (210X297 mm)



THE EL



Rev. Date Page



Door Controller Operating Manual



0.0 2010.11.11 4 / 12



3. External Connectors



Connector Symbol



Name



Description



CN12



OPL



OPL Signal



Open Limit switch, input



CN13



CLL



CLL Signal



Close Limit switch, input



CN15



CLS



CLUTCH Operating Signal



OPB



OPL B Contact



OPC



OPL C Contact



CLB



CLL B Contact



CLC



CLL C Contact



30B



30 B Signal



LDT



Load Detect Signal



OP



Open Command



CLUTCH Operating Signal, input Open Limit switch signal B contact, output Open Limit switch signal C contact, output Close Limit switch signal B contact, output Close Limit switch signal C contact, output Door Controller error signal, output Door Controller Load Detect signal, output Door Open Command, input



CL



Close Command



NUD



Nudge Command



RST



Reset Command



Door Close Command, input Door Nudge Close Command, input Controller Reset Command, input Controller Reset Command, input



24V



+24 V Power supply



+24 V power supply, input



CM



Common ( 0 V )



+24 V Common ( 0 V ), input



VEN



Encoder Power Supply (5V)



Encoder power supply ( 5 V ), output



OVE



Encoder Common ( 0V )



Encoder Common ( 0 V ), output



A



Phase A



Phase A, input



/A



Inv Phase A



Inv Phase A, input



B



Phase B



Phase B, input



/B



Inv Phase B



R



AC 220 V input



S



AC 220 V input



U



Inverter output, U phase



V



Inverter output, V phase



W



Inverter output, W phase



FG



Inverter ground



Inv Phase B, input Input power supply terminal of door controller Input power supply terminal of door controller Output terminal, U.phase of door controller Output terminal, V.phase of door controller Output terminal, W.phase of door controller Frame ground of door controller



CN10



CN9



CN8



CN1



FG



R&D institute



VOLUME 1.



A4 (210X297 mm)



THE EL



Door Controller Operating Manual



Rev. Date Page



0.0 2010.11.11 5 / 12



4. HHT Operation 4.1 HHT Display & Key



4.2 HHT Menu daigram



The keypad menu of HIDC uses a tree data structure as shown in Figure. Door controller logo is displayed in the topmost node. It has 2 sub.menu, [MONITOR] and [PROGRAM]



[MONITOR] is composed of [BASIC], [I/O] and [ERROR]



composed of [CONTROL], [INTERFACE], [FACTORY]



[PROGRAM] is



Each menu has its own information



according to the properties. R&D institute



VOLUME 1.



A4 (210X297 mm)



THE EL



Door Controller Operating Manual



Rev. Date Page



0.0 2010.11.11 6 / 12



5. Calibration The total moving length should be accurately measured



in order to drive the door with



programmed Open/Close pattern. In case of first installment, replacement of a door inverter or changing a parameter of [33_System_Ratio] or [36_Motor_Select] in [01_CONTROL] menu, CALIBRATION is required.



In case that a door operator is not standard or phase.order of motor is not incorrect, See details below. 1. Make sure of connectors between door inverter and motor check the direction of rotation of the motor while the door is being opened. If the direction of rotation is counter clockwise, phase.order of motor and inverter is correct. If it is clockwise, change U.V.W phase.order to U.W.V phase.order. 2 . Make sure of the value of measured speed in [01_MONITOR/01_BASIC/02_FBK RPM] connect the jumper of CON2 in inverter control board to 1.2 or 2.3 in order that the value of [02_FBK RPM Rpm] is positive while the door is being opened.



Check before Calibration 1. Make sure connections of Open limit switch and Close limit switch are correct OPL LED is ON when the door is opened fully and CLL LED is ON when the door is closed fully in a state of correct connections. 2. The parameter can not be changed with a fully opened door. Do the calibration with a fully closed door or in the middle of opening/closing (OLS OFF and CLS OFF).



R&D institute



VOLUME 1.



A4 (210X297 mm)



THE EL



Door Controller Operating Manual



Rev. Date Page



0.0 2010.11.11 7 / 12



Process of Calibration 1. Adjust [PROGRAM/01_CONTROL/38_Keypad_Run] to ON. 2. Make sure of [PROGRAM/01_CONTROL/36_Motor_Select] ( INT7I.UM = 400IM, INT7I.UH = 750IM ) 3. Adjust [PROGRAM/01_CONTROL/35_Door_Type] to installed door type. ( Center Open = CO, Side Open = SO ) 4. Adjust [PROGRAM/01_CONTROL/34_JJ] to JJ of installed door. 5. Change the parameter in [PROGRAM/01_CONTROL/32_Calibration]



to "1"



calibration will then be operated. 6. After Calibration is finished, [PROGRAM/01_CONTROL/32_Calibration] is changed to "2", [38_Keypad_Run] is changed to "0", [31_Total_Length] is changed



to measured



total length of door and Door Inverter is in Auto Mode automatically. It is then driven by C.P command.



R&D institute



VOLUME 1.



A4 (210X297 mm)



THE EL



Door Controller Operating Manual



Rev. Date Page



0.0 2010.11.11 8 / 12



5.1 Data 5.1.1 Monitor/01_BASIC MENU



ITEM



FUNCTION NAME



UNIT



01_REF_RPM



rpm



Command value of motor speed



02_FBK_RPM



rpm



Measured value of motor speed



03_REF_MMPS



mmps



Command value of door speed



04_FBK_MMPS



mmps



Measured value of door speed



05_DC_Volt 06_Running_mm 01 BASIC 07_Rth



5.1.2



NOTE



Vdc



DC Link Voltage



mm



Moving length of the door



.



Temperature of IPM



08_Iu_Offset



A



Offset of U.phase current



09_Iw_Offset



A



Offset of W.phase current



10_RMS_Current



Arms



RMS output current of door controller



11_D.REF_MMPS



mmps



12_D.FBK_MMPS



mmps



Commanded max speed while the door is being driven by pattern. Measured max speed while the door is being driven by pattern.



Monitor/03_ERROR MENU



ERROR



KEYPAD DISPLAY



NO ERROR



NONE



IPM ERROR(H/W)



HW IPM



IPM ERROR(S/W)



SW IPM



OVER CURRENT



SW OC



UNDER VOLTAGE ERROR OVER VOLTAGE ERROR SPI COMMUNICATION ERROR VERSION ERROR



R&D institute



SW UV SW OV SPI FAULT Version Error



DESCRIPTION No generated error. IPM error signal is detected (Occurred immediately) IPM error signal is detected during setting time. (Setting time : 300usec) Output current is higher than a level (level : 400 %, Occurred immediately) DC Link voltage is lower than a level during setting time. (level : 65%, setting time : 500 usec) DC Link voltage is higher than a level during setting time. (level : 130%, setting time : 500 usec) SPROM communication error (when it occurred 2 times consecutively) SPROM Version is different from Main Board Version. (Occurred immediately)



VOLUME 1.



A4 (210X297 mm)



THE EL 5.1.2



Rev. Date Page



Door Controller Operating Manual



0.0 2010.11.11 9 / 12



Monitor/03_ERROR MENU (Continue) ERROR



KEYPAD DISPLAY



INVERTER OVERHEAT



Over Heat



IPM temperature is higher than allowable temperature during setting time (setting time : 60 sec)



OVER LOAD ALERT1



Over Load LV1



Load current is higher than "level1" during "time1" (level1 : 200%, time1 : 5sec)



OVER LOAD ALERT2



Over Load LV2



Load current is higher than "level2" during "time2" (level2 : 150%, time2 : 30sec)



OVERLOAD ALERT3



Over Load LV3



Load current is higher than "level3" during "time3" (level3 : 110%, time3 : 60sec)



OVERSPEED ALERT



Over Speed



UNKNOWN ERROR



Unknown Error



DESCRIPTION



The motor speed is higher than a level during setting time (level : 110%, setting time : 10msec) Unknown error is generated.



5.1.3 Program/01_CONTROL MENU ITEM



01 CONTROL



R&D institute



MAX



MIN



INT7I .UH



INT7I .UM



UNIT



01_OP_Start_sec



0.100



2.000



1.000



0.750



sec



02_OP_Start_Spd



20



500



50



44



mmps



03_OP_Acc



100



1000



400



500



mmps^2



04_OP_Max_Speed



100



1200



400



400



mmps



05_OP_Dec



100



1000



400



500



mmps^2



06_OP_Creep_mm



1



100



5



15



mm



07_OP_Creep_Spd



1



500



10



50



mmps



08_OPL_On_Dec



100



1000



200



300



mmps^2



09_OP_Torque



10



300



150



150



%



10_OP_Lock_Force



10



200



20



80



%



11_CL_Acc



100



1000



325



400



mmps^2



12_CL_Max_Spd



100



1000



300



300



mmps



13_CL_Dec



100



1000



325



400



mmps^2



14_CL_Creep_mm



1



100



5



30



mm



15_CL_Creep_Spd



1



100



10



27



mmps



16_CLS_On_sec



0.100



2.000



0.500



0.300



sec



17_CLS_On_Spd



1



500



90



15



mmps



18_CL_Torque



10



300



120



120



%



FUNCTION NAME



VOLUME 1.



REMARK



A4 (210X297 mm)



THE EL



Rev. Date Page



Door Controller Operating Manual



0.0 2010.11.11 10 / 12



5.1.3 Program/01_CONTROL MENU(Continue) ITEM



01 CONTROL



MAX



MIN



INT7I .UH



INT7I .UM



UNIT



19_CL_Lock_Force



10



200



20



80



%



20_Nudge_Speed



100



600



150



150



mmps



21_Stop_Dec



100



1000



450



900



mmps^2



22_ReAct_Acc



100



1000



450



900



mmps^2



23_Jog_Speed



50



200



100



100



mmps



24_Jog_Acc



100



1000



200



300



mmps^2



25_CLL_On_Spd



1



500



90



15



mmps



26_CL_LOW_Max_Spd



1



1200



200



200



mmps



27_USE_CAN



OFF



ON



ON



ON



.



28_Reserved



.



.



0



0



.



29_Belt_Slip_MM



100



3000



100



100



mm



30_CLS2CLL_MM



.



.



*



*



mm



31_Total_Length



.



.



*



*



mm



32_Calibration



0



1



0



0



.



33_System_Ratio



10



150



25



70



mm/rev



34_JJ



100



3000



900



1000



mm



35_Door_Type



CO



SO



CO



CO



.



36_Motor_Select



200 IM



750 IM



750 IM



400 IM



.



37_Keypad_Cmd



STOP



NUDGE



STOP



STOP



.



38_Keypad_Run



OFF



ON



OFF



OFF



.



39_CL 0 Run Use



OFF



ON



ON



ON



.



FUNCTION NAME



REMARK



Only UH Type



No modification



Note) UH Type and UM Type have different door mechanism and control programs and therefore are not compatible use the correct type to your door system.



R&D institute



VOLUME 1.



A4 (210X297 mm)



THE EL



Door Controller Operating Manual



Rev. Date Page



0.0 2010.11.11



Figure 1



While the door is being opened, the pattern of speed & signals



Figure 2



While the door is being closed, the pattern of speed & signals



11 / 12



(HIDC.INT7I.UH type)



R&D institute



VOLUME 1.



A4 (210X297 mm)



THE EL



Rev. Date Page



Door Controller Operating Manual



0.0 2010.11.11 12 / 12



5.1.4 Interface Menu



ITEM



FUNCTION NAME



MINIMUM VALUE



MAXIMUM VALUE



INITIAL VALUE



UNIT



NOTE



01_DAC_Ch1_SLT 02_DAC_Ch1_Max 03_DAC_Ch2_SLT 04_DAC_Ch2_Max 05_DAC_Ch3_SLT



HIDC has analog outputs in order to measure the actual driving conditions with a measuring instrument. These menus set the measurement targets and ranges.



06_DAC_Ch3_Max 02_ INTERFACE



07_DAC_Ch4_SLT 08_DAC_Ch4_Max 09_Reserved



.



.



.



.



10_Error Clear



OFF



ON



OFF



.



11_SPROM_Init



OFF



ON



OFF



.



12_Flash_Ver



.



.



.



.



13_SPROM_Ver



.



.



.



.



OFF



ON



OFF



.



14 CTRL Init



No modified



No modified No modified



5.1.5 Factory Menu Parameters in FACTORY MENU are set when HIDC.INT7I is produced at factory. These are protected to not change with secret number.



R&D institute



VOLUME 1.