Alarms and Corrective Action [PDF]

  • 0 0 0
  • Suka dengan makalah ini dan mengunduhnya? Anda bisa menerbitkan file PDF Anda sendiri secara online secara gratis dalam beberapa menit saja! Sign Up
File loading please wait...
Citation preview

CONTENTS



List of alarms



NEC Confidential



Reliance RJIL



1



Alarm list ODU



Alarm Name



Category



Severity



ODU Alarm



Alarm



MJ



Replace Faulty ODU at Local (Alarm) end



ODU



Type Mismatch



Alarm



MJ



Check ODU installed Model & replace with compatible radio model



ODU



TX Power



Alarm



MJ



Replace Faulty ODU at Local (Alarm) end



ODU



MJ



Check IF cable length. Maximum permissible length for 5DFBE is 150 mts.



IF cable



TX Input



Alarm



RX Level



Alarm



ODU CPU / Cable Open



Alarm



NEC Confidential



Corrective Action



Fault Category



Check if ODU Tx power at Opposite end, If yes replace ODU at near end. Also check is link is misaligned or water ingress in OMT/Antenna at both ned ODU MJ



Replace IF cable or redo connectorization



Reliance RJIL



IF cable



2



Alarm list MODEM Alarm Name ODU Power Supply LOF



Category Alarm Alarm



Severity Corrective Action MN Modem Faulty. Reconnect using 2nd Modem else replace MDU MJ Check RSL / Connectorization / Interference in link



Fault Category MDU RF Link



Frame ID High BER Low BER Early warning IF Cable Short



Alarm Alarm Alarm Alarm Alarm



MJ MJ MN Warning MJ



L2SYNC Loss



Alarm



MJ



Configuration RF Link RF Link RF Link IF Cable MDU/ Connector



MOD RDI Unlocked



Alarm Alarm Alarm



Modem may be faulty. Confirm the same via IF loopback. If no errors in PMON for 15 min time interval on that Modem then Modem not faulty, MJ else faulty MDU Warning Indicate an fault at the far end Opposite Site MJ The Timing source is no more available hence clock unlocked. RF Link



AMR Range Mismatch



Alarm



MJ



Compression Setting mismatch Communication Fail



Alarm Alarm



MJ MJ



Module TX Bus Error RX BUS Error Radio Traffic Aggregation Setting Mismatch



Alarm Alarm Alarm Alarm



MN MJ MJ MJ



XIF CLK Fail



Alarm Alarm



MJ MJ



NEC Confidential



Frame ID in Near end & Far end not the same. Make it same at both end Check RSL / Connectorization / Interference in link Check RSL / Connectorization / Interference in link Check RSL / Connectorization / Interference in link IF cable faulty. Repace or redo connectorization MDU Faulty. Replace with good MDU, Connectorisation issue, check CNR setting for AMR



Indicates mismatch in AMR setting in local modem and opposite modem Configuration Header compression setting of local and opposite modems are not the same Configuration MDU Faulty. Replace with good MDU MDU Modem may be faulty. Confirm the same via IF loopback. If no errors in PMON for 15 min time interval on that Modem then Modem not faulty, else faulty MDU Faulty. Replace with good MDU MDU Faulty. Replace with good MDU Local and opposite side Traffic aggregation setting not the same Login to MDU & go to Modem Maintenance Control. Go to XPIC Reset & set Forced Reset. If problem solved else replace MDU Reference Clock failed (when modem is selected as timing source)



Reliance RJIL



MDU MDU MDU Configuration Configuration / MDU RF Link



3



Alarm IDU



Alarm Name



Category



Severity



ETH OAM LOC ETH OAM Mismerge ETH OAM RDI



Alarm Alarm Alarm



MJ MN MN



RF failure in ring topology detected. Ethernet Ring Protection to act MEG /MEP duplication in ERPS setting Receive Ether OAM RDI (Remote Defect Indication)



RF Link Configuration RF Link



ETH OAM Unexpected MEP Communication Fail



Alarm Alarm



MN MJ



Ether OAM Unexpected MEP and Ether OAM Unexpected Period have been detected MDU Faulty. Replace with good MDU



Configuration MDU



LTI



Alarm



MJ



Loss of timing information from all reference source detected



Input Timing Source



CLK Drift SSM Fail MDU CPU alarm memory Fail Temperature BUS Error Radio Traffic Aggregation Link



Alarm Alarm Alarm Alarm Alarm Alarm Alarm



MN MN MN MJ MJ MJ MJ



Selected Reference Clock Source Frequency drift detected Check timing Source MDU Faulty. Replace with good MDU MDU Faulty. Replace with good MDU The Temperature exceed the threshold MDU Faulty. Replace with good MDU When Modem 1 and Modem 2 radio link fails



MDU MDU MDU MDU Temperature MDU MDU



License Mismatch



Alarm



MN



Unable to update the License key as mismatch in license file being updated via to Sr. no. of equipment being upgraded



Configuration



NEC Confidential



Corrective Action



Reliance RJIL



Fault Category



4



Alarm list GbE



Alarm Name



Category



Severity



Corrective Action



Fault Category



CLK Fail



Alarm



MN



Reference Clock failed (when GBE interface is selected as a clock timing source)



ETH LOS ETH TF (Transmit Failure) TX BUS Error RX BUS Error SFP removed



Alarm Alarm Alarm Alarm Alarm



MJ MJ MJ MJ MJ



Loss of Signal detected at the indicated Ethernet Port (Optical).Check Tx or Optical Patch cord Replace GBE Interface / MDU GBE Interface faulty GBE Interface faulty Indicate that the SFP is not plugged in



SFP Type Mismatch Remote Dying Gasp Remote Link Fault



Alarm Alarm Alarm



MJ Mj Mj



Mounted SFP and the registered information does not match SPFP Remote site equipment is in reboot process Opp Site down Link failure has been detected at the opposite site Opp Site down



NEC Confidential



Reliance RJIL



Input Timing Source Optical Cable or Router TX SFP or MDU SFP or MDU SFP or MDU SPF



5



END of Presentation



NEC Confidential



Reliance RJIL



6