10 0 348 KB
CONTENTS
List of alarms
NEC Confidential
Reliance RJIL
1
Alarm list ODU
Alarm Name
Category
Severity
ODU Alarm
Alarm
MJ
Replace Faulty ODU at Local (Alarm) end
ODU
Type Mismatch
Alarm
MJ
Check ODU installed Model & replace with compatible radio model
ODU
TX Power
Alarm
MJ
Replace Faulty ODU at Local (Alarm) end
ODU
MJ
Check IF cable length. Maximum permissible length for 5DFBE is 150 mts.
IF cable
TX Input
Alarm
RX Level
Alarm
ODU CPU / Cable Open
Alarm
NEC Confidential
Corrective Action
Fault Category
Check if ODU Tx power at Opposite end, If yes replace ODU at near end. Also check is link is misaligned or water ingress in OMT/Antenna at both ned ODU MJ
Replace IF cable or redo connectorization
Reliance RJIL
IF cable
2
Alarm list MODEM Alarm Name ODU Power Supply LOF
Category Alarm Alarm
Severity Corrective Action MN Modem Faulty. Reconnect using 2nd Modem else replace MDU MJ Check RSL / Connectorization / Interference in link
Fault Category MDU RF Link
Frame ID High BER Low BER Early warning IF Cable Short
Alarm Alarm Alarm Alarm Alarm
MJ MJ MN Warning MJ
L2SYNC Loss
Alarm
MJ
Configuration RF Link RF Link RF Link IF Cable MDU/ Connector
MOD RDI Unlocked
Alarm Alarm Alarm
Modem may be faulty. Confirm the same via IF loopback. If no errors in PMON for 15 min time interval on that Modem then Modem not faulty, MJ else faulty MDU Warning Indicate an fault at the far end Opposite Site MJ The Timing source is no more available hence clock unlocked. RF Link
AMR Range Mismatch
Alarm
MJ
Compression Setting mismatch Communication Fail
Alarm Alarm
MJ MJ
Module TX Bus Error RX BUS Error Radio Traffic Aggregation Setting Mismatch
Alarm Alarm Alarm Alarm
MN MJ MJ MJ
XIF CLK Fail
Alarm Alarm
MJ MJ
NEC Confidential
Frame ID in Near end & Far end not the same. Make it same at both end Check RSL / Connectorization / Interference in link Check RSL / Connectorization / Interference in link Check RSL / Connectorization / Interference in link IF cable faulty. Repace or redo connectorization MDU Faulty. Replace with good MDU, Connectorisation issue, check CNR setting for AMR
Indicates mismatch in AMR setting in local modem and opposite modem Configuration Header compression setting of local and opposite modems are not the same Configuration MDU Faulty. Replace with good MDU MDU Modem may be faulty. Confirm the same via IF loopback. If no errors in PMON for 15 min time interval on that Modem then Modem not faulty, else faulty MDU Faulty. Replace with good MDU MDU Faulty. Replace with good MDU Local and opposite side Traffic aggregation setting not the same Login to MDU & go to Modem Maintenance Control. Go to XPIC Reset & set Forced Reset. If problem solved else replace MDU Reference Clock failed (when modem is selected as timing source)
Reliance RJIL
MDU MDU MDU Configuration Configuration / MDU RF Link
3
Alarm IDU
Alarm Name
Category
Severity
ETH OAM LOC ETH OAM Mismerge ETH OAM RDI
Alarm Alarm Alarm
MJ MN MN
RF failure in ring topology detected. Ethernet Ring Protection to act MEG /MEP duplication in ERPS setting Receive Ether OAM RDI (Remote Defect Indication)
RF Link Configuration RF Link
ETH OAM Unexpected MEP Communication Fail
Alarm Alarm
MN MJ
Ether OAM Unexpected MEP and Ether OAM Unexpected Period have been detected MDU Faulty. Replace with good MDU
Configuration MDU
LTI
Alarm
MJ
Loss of timing information from all reference source detected
Input Timing Source
CLK Drift SSM Fail MDU CPU alarm memory Fail Temperature BUS Error Radio Traffic Aggregation Link
Alarm Alarm Alarm Alarm Alarm Alarm Alarm
MN MN MN MJ MJ MJ MJ
Selected Reference Clock Source Frequency drift detected Check timing Source MDU Faulty. Replace with good MDU MDU Faulty. Replace with good MDU The Temperature exceed the threshold MDU Faulty. Replace with good MDU When Modem 1 and Modem 2 radio link fails
MDU MDU MDU MDU Temperature MDU MDU
License Mismatch
Alarm
MN
Unable to update the License key as mismatch in license file being updated via to Sr. no. of equipment being upgraded
Configuration
NEC Confidential
Corrective Action
Reliance RJIL
Fault Category
4
Alarm list GbE
Alarm Name
Category
Severity
Corrective Action
Fault Category
CLK Fail
Alarm
MN
Reference Clock failed (when GBE interface is selected as a clock timing source)
ETH LOS ETH TF (Transmit Failure) TX BUS Error RX BUS Error SFP removed
Alarm Alarm Alarm Alarm Alarm
MJ MJ MJ MJ MJ
Loss of Signal detected at the indicated Ethernet Port (Optical).Check Tx or Optical Patch cord Replace GBE Interface / MDU GBE Interface faulty GBE Interface faulty Indicate that the SFP is not plugged in
SFP Type Mismatch Remote Dying Gasp Remote Link Fault
Alarm Alarm Alarm
MJ Mj Mj
Mounted SFP and the registered information does not match SPFP Remote site equipment is in reboot process Opp Site down Link failure has been detected at the opposite site Opp Site down
NEC Confidential
Reliance RJIL
Input Timing Source Optical Cable or Router TX SFP or MDU SFP or MDU SFP or MDU SPF
5
END of Presentation
NEC Confidential
Reliance RJIL
6