Speck Perangkat Smart 3 [PDF]

  • 0 0 0
  • Suka dengan makalah ini dan mengunduhnya? Anda bisa menerbitkan file PDF Anda sendiri secara online secara gratis dalam beberapa menit saja! Sign Up
File loading please wait...
Citation preview

SITE MODELLING PROJECT LTE 2017 2018 (TP)



MODEL 3. TDD (8T8R) + FDD (2T4R) ON TOWER NLOS Integrated ODU :PTP 650



Splitzen (Penangkal Petir)



DB TDD+FDD ANTENNA – 12 PORT (BA-B7B74Q7X90V-00) Total Weight 3 Pcs Dimensions (H x W x D)



147 kg @49Kg 2690x 448 x 188(mm)



DB TDD+ FDD Antenna – 12 Port (3 Pcs) NLOS / MW (If FO Not Available) RRU FDD (2T4R) (3 Pcs)+ FDD Filter (3 Pcs)



Total Weight Dimensions (H x W x D)



4.1 kg 371 x 371 x 81 (mm)



RRU FDD 2T4R (ZXSDR R8862A ) Total Weight 3 Pcs Dimensions (H x W x D)



45 kg @15Kg 422x 218 x 133 (mm)



FDD Filter 1D-IMF 814-879 RJ 880.1 27dB DC Total Weight 3 Pcs Dimensions (H x W x D)



24 kg @8Kg 256 x 174 x 109 (mm)



RRU TDD 8T8R (ZXSDR R8978 S2300) RRU TDD (8T8R) (3 Pcs)



Total Weight 3 Pcs Dimensions (H x W x D)



63 kg @21Kg 430 x 400 x 125 (mm)< 22 L



Cabinet ZXDU68 W201 (Integrated cabinet) SS TOWER



Total Weight Dimensions (H x W x D)



145.3Kg 1900 x 600 x 600 (mm)



BBU – ZXSDR 8300 Vertikal Cable Tray GPS Elv + 10.00



GPS Antenna Distribution Unit / Rectifier Module



OUTDOOR LTE EQUIPMENT ZXDU68 W201



Battery 12V150AH AGM



ZXD3000 Rectifier Module



NEW No



ADDED EQUIPMENT



Equipment



Type



Number



Dimension (mm) (HxWxD)



Total Weight



Remark



1



Antenna



BA-B7B74Q7X90V-00



3



2690x 448 x 188 (mm



147 Kg



Rosenberger 6Xpol,2x (810-890)/4 X (2300-2400)Mhz 12 Port FDD/TDD Hybrid Antenna with Integrated RET



2



Antenna NLOS/MW



NLOS Integrated ODU :PTP 650



1



371 x 371 x 81 mm



4.1 Kg



Integrated Outdoor Unit (ODU):



Antenna MW



Ultra high Performance Low Profile



1



0.6 (2ft) & 0.3 (1ft)



(0.6) 18.2 kg & (0.3) 12.2Kg



RRU



ZXSDR R8978 S2300



3



430 x 400 x 125 (mm)< 22 L



63 Kg



TDD 8T8R



ZXSDR R8862A



3



45 Kg



FDD 2T4R



24



Only for FDD



3



422 x 218 x 133mm



4



FDD Filter



1D-IMF 814-879 RJ 880.1 27dB DC



3



256 x 174 x 109 (mm)



5



Power



ZXDU68 W201 DC Power System



1



1900 x 600 x 600 (mm) (Integrated cabinet) 8U,19 Inch Standar Equipment



6



E-Guard



EISU



1



7



BBU



B8300



1



132.6 × 482.6 × 197 (mm)



< 10 kg



8



Battery



12V150AH AGM



8



551x110x287/Cell



368kg @46Kg/Cell



9



KWH Box



1



600x400x300mm



25Kg



10



GPS



Pole Mounted



1



145.3Kg



Gross Weight Packed Antenna, kg



Build In ZXDU68 W201 Outdoor Cabinet



< 10 kg (6 baseband boards) Build In ZXDU68 W201 Outdoor Cabinet



TP_CME SPECIFICATION No. 1



DESCRIPTION Structure : Designed Wind Speed Design Calculation Load Smartfren - Microwave antenna (diameter 0.6) - Cellular antenna - RRU - Filter Material properties (minimum) - Bolt & Nut - Anchoring Bolt - Plate - Sling - Welding - Finishing (All Steel Part no exception, including bolt and nut)



2



Pole RT



: 84 km/h (operation), 120 km/h (max) : EIA -222-G :1 :3 :3 :3



- 2 unit - 6 unit - 6 unit unit



: 84 km/h (operation), 120 km/h (max) : EIA -222-G : 1 - 2 unit : 3 - 6 unit Refer: to SF-TP 3-6 unit : 3 unit



Contract of



Monopole >16 inchi, GFSpace



: 84 km/h (operation), 120 km/h (max) : EIA -222-G : 1 - 2 unit : 3 -Refer 6 unit to SF-TP antenna : 3 - 6 unit number : 3 unit



MCP Zero Footprint



G-Wire



: 84 km/h (operation), 120 km/h (max) : EIA -222-G



: 84 km/h (operation), 120 km/h (max) : EIA -222-G



: 1 - 2 unit



: 1 - 2 unit



: 3 - 6 unit : 3 unit



: 3 - 6 unit : 3 unit



Contract : 3 - 6 of unitantenna number : 3 - 6 unit



SS 400



Schedule 40 & SS 400



Schedule 40 & SS 401



Schedule 40 & SS 402



Schedule 40 & SS 403



: HTB 8.8 : STK-41 : 240MPa



: HTB 8.8 : STK-41 : 240MPa



: HTB 8.8 : STK-41 : 240MPa



: HTB 8.8 : STK-41 : 240MPa



: Electrode E70XX : Hot dipped Galvanized, minimum 75 - 80 micron



: Electrode E70XX : Hot dipped Galvanized, minimum 75 - 80 micron



: Electrode E70XX : Hot dipped Galvanized, minimum 75 - 80 micron



: Electrode E70XX : Hot dipped Galvanized, minimum 75 - 80 micron



: HTB 8.8 : STK-41 : 240MPa : Bridon, Wire : Electrode E70XX : Hot dipped Galvanized, minimum 75 - 80 micron



Safety and Associated Requirement Climbing Ladder



Foot step/ step bolt Safety Cage Rest Platform Working Platform



Cable tray



3



SST / MT



Mounting Antenna / MW - Design Material properties (minimum) - Finishing



width : 400 mm, spacing step : 300 mm & step rungs : minimum 16 mm,



Floor to floor



width : 300-400 mm, spacing step : 300 mm & step rungs : minimum 16 mm,



RT : Floor to floor



-



spacing step : 300 -375 mm & spacing step : 300 -375 mm foot step minimum 16 mm & foot step minimum 16 mm Plat bar 40.4. Plat bar 40.4. minimum every 20 m minimum every 20 m Near the antennas and RRU Near the antennas and RRU position position : vertical rail with 300-400mm : horizontal flats steel rungs : vertical rail with 300-400mm : horizontal flats steel rungs width, horizontal flats steel size 40x4 mm, spacing vertical width, horizontal flats steel size 40x4 mm, spacing rungs size 40x4 mm, spacing 1000 mm rungs size 40x4 mm, spacing vertical 1000 mm vertical 1000 mm & spacing vertical 1000 mm & spacing horizontal 500 mm horizontal 500 mm



As per agreed design As per agreed design As per agreed design Pipe Schedule 40, Steel Profile Pipe Schedule 40, Steel Profile Pipe Schedule 40, Steel SS 400, Steel Plate SS 400, Steel Plate Profile SS 400, Steel Plate : Hot dipped : Hot dipped : Hot dipped Galvanized, minimum Galvanized, minimum Galvanized, minimum 75 - 80 micron 75 - 80 micron 75 - 80 micron



As per agreed design Pipe Schedule 40, Steel Profile SS 400, Steel Plate : Hot dipped Galvanized, minimum 75 - 80 micron



As per agreed design Pipe Schedule 40, Steel Profile SS 400, Steel Plate : Hot dipped Galvanized, minimum 75 - 80 micron



TP_CME SPECIFICATION



No. 4



DESCRIPTION



6



7



Pole RT



Monopole >16 inchi, GF-Space



MCP Zero Footprint



G-Wire



Grounding Bar - Position



5



SST / MT



- Material Space /eNode Placement - Pad /space for LTE e Node B - Material ACPDB , KWH meter - Design and material - PLN Capacity (LTE) : TDD FDD (post paid) Perimeter Fence - Requirement



(SST) top, middle, bottom ( MT) top, bottom top (h>6), bottom



top, bottom



top, bottom



top, middle, bottom



Galvanized Steel, Alumunium, Copper



Galvanized Steel, Alumunium, Copper



Galvanized Steel, Alumunium, Copper



Galvanized Steel, Alumunium, Copper



Galvanized Steel, Alumunium, Copper



1.3 x 2.0 m Concrete



1.3 x 2.0 m Concrete, IWF Steel



1.3 x 2.0 m Concrete



on pole -



1.3 x 2.0 m Concrete, IWF Steel



As per agreed design 4.4 KVA



As per agreed design 4.4 KVA



As per agreed design 4.4 KVA



As per agreed design 4.4 KVA



As per agreed design 4.4 KVA



GF : Required



RT : Safety Parapet



GF : Required



-



GF : Required RT : Safety Parapet



TP…………………………………



---------------------------------------------