SITE MODELLING PROJECT LTE 2017 2018 (TP)
MODEL 3. TDD (8T8R) + FDD (2T4R) ON TOWER NLOS Integrated ODU :PTP 650
Splitzen (Penangkal Petir)
DB TDD+FDD ANTENNA – 12 PORT (BA-B7B74Q7X90V-00) Total Weight 3 Pcs Dimensions (H x W x D)
147 kg @49Kg 2690x 448 x 188(mm)
DB TDD+ FDD Antenna – 12 Port (3 Pcs) NLOS / MW (If FO Not Available) RRU FDD (2T4R) (3 Pcs)+ FDD Filter (3 Pcs)
Total Weight Dimensions (H x W x D)
4.1 kg 371 x 371 x 81 (mm)
RRU FDD 2T4R (ZXSDR R8862A ) Total Weight 3 Pcs Dimensions (H x W x D)
45 kg @15Kg 422x 218 x 133 (mm)
FDD Filter 1D-IMF 814-879 RJ 880.1 27dB DC Total Weight 3 Pcs Dimensions (H x W x D)
24 kg @8Kg 256 x 174 x 109 (mm)
RRU TDD 8T8R (ZXSDR R8978 S2300) RRU TDD (8T8R) (3 Pcs)
Total Weight 3 Pcs Dimensions (H x W x D)
63 kg @21Kg 430 x 400 x 125 (mm)< 22 L
Cabinet ZXDU68 W201 (Integrated cabinet) SS TOWER
Total Weight Dimensions (H x W x D)
145.3Kg 1900 x 600 x 600 (mm)
BBU – ZXSDR 8300 Vertikal Cable Tray GPS Elv + 10.00
GPS Antenna Distribution Unit / Rectifier Module
OUTDOOR LTE EQUIPMENT ZXDU68 W201
Battery 12V150AH AGM
ZXD3000 Rectifier Module
NEW No
ADDED EQUIPMENT
Equipment
Type
Number
Dimension (mm) (HxWxD)
Total Weight
Remark
1
Antenna
BA-B7B74Q7X90V-00
3
2690x 448 x 188 (mm
147 Kg
Rosenberger 6Xpol,2x (810-890)/4 X (2300-2400)Mhz 12 Port FDD/TDD Hybrid Antenna with Integrated RET
2
Antenna NLOS/MW
NLOS Integrated ODU :PTP 650
1
371 x 371 x 81 mm
4.1 Kg
Integrated Outdoor Unit (ODU):
Antenna MW
Ultra high Performance Low Profile
1
0.6 (2ft) & 0.3 (1ft)
(0.6) 18.2 kg & (0.3) 12.2Kg
RRU
ZXSDR R8978 S2300
3
430 x 400 x 125 (mm)< 22 L
63 Kg
TDD 8T8R
ZXSDR R8862A
3
45 Kg
FDD 2T4R
24
Only for FDD
3
422 x 218 x 133mm
4
FDD Filter
1D-IMF 814-879 RJ 880.1 27dB DC
3
256 x 174 x 109 (mm)
5
Power
ZXDU68 W201 DC Power System
1
1900 x 600 x 600 (mm) (Integrated cabinet) 8U,19 Inch Standar Equipment
6
E-Guard
EISU
1
7
BBU
B8300
1
132.6 × 482.6 × 197 (mm)
< 10 kg
8
Battery
12V150AH AGM
8
551x110x287/Cell
368kg @46Kg/Cell
9
KWH Box
1
600x400x300mm
25Kg
10
GPS
Pole Mounted
1
145.3Kg
Gross Weight Packed Antenna, kg
Build In ZXDU68 W201 Outdoor Cabinet
< 10 kg (6 baseband boards) Build In ZXDU68 W201 Outdoor Cabinet
TP_CME SPECIFICATION No. 1
DESCRIPTION Structure : Designed Wind Speed Design Calculation Load Smartfren - Microwave antenna (diameter 0.6) - Cellular antenna - RRU - Filter Material properties (minimum) - Bolt & Nut - Anchoring Bolt - Plate - Sling - Welding - Finishing (All Steel Part no exception, including bolt and nut)
2
Pole RT
: 84 km/h (operation), 120 km/h (max) : EIA -222-G :1 :3 :3 :3
- 2 unit - 6 unit - 6 unit unit
: 84 km/h (operation), 120 km/h (max) : EIA -222-G : 1 - 2 unit : 3 - 6 unit Refer: to SF-TP 3-6 unit : 3 unit
Contract of
Monopole >16 inchi, GFSpace
: 84 km/h (operation), 120 km/h (max) : EIA -222-G : 1 - 2 unit : 3 -Refer 6 unit to SF-TP antenna : 3 - 6 unit number : 3 unit
MCP Zero Footprint
G-Wire
: 84 km/h (operation), 120 km/h (max) : EIA -222-G
: 84 km/h (operation), 120 km/h (max) : EIA -222-G
: 1 - 2 unit
: 1 - 2 unit
: 3 - 6 unit : 3 unit
: 3 - 6 unit : 3 unit
Contract : 3 - 6 of unitantenna number : 3 - 6 unit
SS 400
Schedule 40 & SS 400
Schedule 40 & SS 401
Schedule 40 & SS 402
Schedule 40 & SS 403
: HTB 8.8 : STK-41 : 240MPa
: HTB 8.8 : STK-41 : 240MPa
: HTB 8.8 : STK-41 : 240MPa
: HTB 8.8 : STK-41 : 240MPa
: Electrode E70XX : Hot dipped Galvanized, minimum 75 - 80 micron
: Electrode E70XX : Hot dipped Galvanized, minimum 75 - 80 micron
: Electrode E70XX : Hot dipped Galvanized, minimum 75 - 80 micron
: Electrode E70XX : Hot dipped Galvanized, minimum 75 - 80 micron
: HTB 8.8 : STK-41 : 240MPa : Bridon, Wire : Electrode E70XX : Hot dipped Galvanized, minimum 75 - 80 micron
Safety and Associated Requirement Climbing Ladder
Foot step/ step bolt Safety Cage Rest Platform Working Platform
Cable tray
3
SST / MT
Mounting Antenna / MW - Design Material properties (minimum) - Finishing
width : 400 mm, spacing step : 300 mm & step rungs : minimum 16 mm,
Floor to floor
width : 300-400 mm, spacing step : 300 mm & step rungs : minimum 16 mm,
RT : Floor to floor
-
spacing step : 300 -375 mm & spacing step : 300 -375 mm foot step minimum 16 mm & foot step minimum 16 mm Plat bar 40.4. Plat bar 40.4. minimum every 20 m minimum every 20 m Near the antennas and RRU Near the antennas and RRU position position : vertical rail with 300-400mm : horizontal flats steel rungs : vertical rail with 300-400mm : horizontal flats steel rungs width, horizontal flats steel size 40x4 mm, spacing vertical width, horizontal flats steel size 40x4 mm, spacing rungs size 40x4 mm, spacing 1000 mm rungs size 40x4 mm, spacing vertical 1000 mm vertical 1000 mm & spacing vertical 1000 mm & spacing horizontal 500 mm horizontal 500 mm
As per agreed design As per agreed design As per agreed design Pipe Schedule 40, Steel Profile Pipe Schedule 40, Steel Profile Pipe Schedule 40, Steel SS 400, Steel Plate SS 400, Steel Plate Profile SS 400, Steel Plate : Hot dipped : Hot dipped : Hot dipped Galvanized, minimum Galvanized, minimum Galvanized, minimum 75 - 80 micron 75 - 80 micron 75 - 80 micron
As per agreed design Pipe Schedule 40, Steel Profile SS 400, Steel Plate : Hot dipped Galvanized, minimum 75 - 80 micron
As per agreed design Pipe Schedule 40, Steel Profile SS 400, Steel Plate : Hot dipped Galvanized, minimum 75 - 80 micron
TP_CME SPECIFICATION
No. 4
DESCRIPTION
6
7
Pole RT
Monopole >16 inchi, GF-Space
MCP Zero Footprint
G-Wire
Grounding Bar - Position
5
SST / MT
- Material Space /eNode Placement - Pad /space for LTE e Node B - Material ACPDB , KWH meter - Design and material - PLN Capacity (LTE) : TDD FDD (post paid) Perimeter Fence - Requirement
(SST) top, middle, bottom ( MT) top, bottom top (h>6), bottom
top, bottom
top, bottom
top, middle, bottom
Galvanized Steel, Alumunium, Copper
Galvanized Steel, Alumunium, Copper
Galvanized Steel, Alumunium, Copper
Galvanized Steel, Alumunium, Copper
Galvanized Steel, Alumunium, Copper
1.3 x 2.0 m Concrete
1.3 x 2.0 m Concrete, IWF Steel
1.3 x 2.0 m Concrete
on pole -
1.3 x 2.0 m Concrete, IWF Steel
As per agreed design 4.4 KVA
As per agreed design 4.4 KVA
As per agreed design 4.4 KVA
As per agreed design 4.4 KVA
As per agreed design 4.4 KVA
GF : Required
RT : Safety Parapet
GF : Required
-
GF : Required RT : Safety Parapet
TP…………………………………
---------------------------------------------