Guide of Commissioning IPasolink 20180420 [PDF]

  • 0 0 0
  • Suka dengan makalah ini dan mengunduhnya? Anda bisa menerbitkan file PDF Anda sendiri secara online secara gratis dalam beberapa menit saja! Sign Up
File loading please wait...
Citation preview

ALITA PRAYA MITRA



|



Guide of Commissioning iPasolink



Ver. 5.1 Edition 2018



Enabling Quality of Experience for Everyone



Contents Introduce Login Firmware Equipment Configuration Radio Configuration AMR/Radio Mapping Configuration Network Management Configuration Modem Function Setting ETH Function Setting E1/STM1 Cross connect Setting Equipment Clock Synchronization Metering Equipment Utility User Account Inventory PMON/RMON Report S/W License Setup Radio Interference Current Status Enabling Quality of Experience for Everyone



ALITA PRAYA MITRA



|



Vision of commissioning Local & Remote Check & Upgrade Firmware Setting NE Name, modem & Protection Setting Frequency, Bandwith & Modulation Setting AMR, E1 & STM1 Setting IP & Routing Setting Modem Port Name, Radio Switch (1+1), Tx Power Validasi (Setting Port ETH & Setting VLAN), Setting LAG Name (2+0) & QoS Cross Connect Setting & E1/STM1 Port Setting Setting Master/Slave Check Rx Signal Setting Date/Time Setting SAPMFtp & SNMP Inventory Information & License Information Check performance Inject License Scan Frequency Clear Alarm



ALITA PRAYA MITRA



|



COMMISSIONING Project commissioning is the process of assuring that all systems and components of a building or industrial plant are designed, installed, tested, operated, and maintained according to the operational requirements of the owner or final client. Enabling Quality of Experience for Everyone



LOGIN



Guide of Commissioning iPasolink



 Setting Obtain an IP address automatically pada laptop  Login menggunakan Browser, Chrome, Mozilla dll IP Local iPaso User Name Password



: 172.17.254.253 : Admin : 12345678



Admin 12345678



Enabling Quality of Experience for Everyone



Guide of Commissioning iPasolink



Firmware  iPASO200FW_3.00.41  iPASOLINK1000-idufw-v3.55.02  iPASO400A-v3.52.06  iPASOLINK400-idufw-v3.74.03



• Pastikan IDU yang diinstal menggunakan Firmware terbaru. • Hubungi PiC dari Alita bila belum menggunakan Firmware terbaru. • Upgrade sesuai dengan Method of Procedure (MOP) Upgrade FirmWare. • Tahapan upgrade iPaso1000 mulai Ver. 2.20.11 --> Ver. 3.00.12 --> Ver. 3.01.04 --> Ver. 3.50.05 --> Ver. 3.55.02 (Latest version) Enabling Quality of Experience for Everyone



Guide of Commissioning iPasolink



Equipment Configuration Format Lama (bila masih menggunakan site ID)  Setting NE Name



Format: Site Code-Site Name-Index Site Code : Kode site yang sedang diinstal Site Name : Nama site yang sedang diinstal Index : Penomoran IDU di site tersebut Untuk penomoran index iPasolink pada suatu site berdasarkan jumlah perangkat iPaso yang ada di site tersebut, atau hubungi tim ServiceDesk (yang mengalokasikan IP untuk NMS) untuk informasi lebih detail. Enabling Quality of Experience for Everyone



Guide of Commissioning iPasolink



Equipment Configuration  Step 1



Equipment setup > Equipment Configuration > Setup (setting NE Name pastikan sudah sesuai standar, contoh : 3214-Ranco Indah-2)



> NEXT 2 1 3



4



Enabling Quality of Experience for Everyone



Guide of Commissioning iPasolink



Equipment Configuration  Step 2 (pilih slot dan type modem yang akan di config/install dan pastikan modem yang dipasang sudah sesuai propose slot pada MOP)



> NEXT



1



2



Enabling Quality of Experience for Everyone



Guide of Commissioning iPasolink



Equipment Configuration  Step 3 (Setting GRP Configuration contoh jika konfigurasi 1+1)



> NEXT



Setting jika config 1+1



1



2 Enabling Quality of Experience for Everyone



Guide of Commissioning iPasolink



Equipment Configuration  Step 4 (blok biru menandakan settingan yang sudah dilakukan, pastikan tidak salah setting)



> OK



Enabling Quality of Experience for Everyone



Guide of Commissioning iPasolink



Equipment Configuration Contoh Label Site Name : 3214-Rancho Indah-2 Modem sudah di creat di slot 1



Enabling Quality of Experience for Everyone



Guide of Commissioning iPasolink



Equipment Configuration Format Baru (menggunakan tower index) Note : Acuannya berdasarkan link budget (LB) jika di LB sudah menggunakan tower indeks, maka harus di setting menggunakan format baru (tower indeks) Format : TOWER INDEX_IDU Index



Example : SUM-BE-BGL-0113_2



Tower Index



IDU Index



Enabling Quality of Experience for Everyone



Guide of Commissioning iPasolink



Radio Configuration  Pastikan konfigurasi radio di setting sesuai standar yang berlaku  Tabel konfigurasi radio (Update 31 Mei 2017)



Enabling Quality of Experience for Everyone



Guide of Commissioning iPasolink



Radio Configuration  Step 1



Equipment setup > Radio Configuration > Setup (Perhatikan di slot berapa modem yang akan di konfigurasi caranya dengan melihat SET POSITION, next jika akan setting konfigurasi modem pada slot selanjutnya )



Enabling Quality of Experience for Everyone



Guide of Commissioning iPasolink



Radio Configuration Setting Channel Spacing, Reference Modulation dan Frequency berdasarkan SOW yang dikerjakan dan pastikan frekuensi yang di setting adalah alokasi frekuensi legal berdasarkan channel spacing/bandwith yang digunakan



> NEXT



Enabling Quality of Experience for Everyone



Guide of Commissioning iPasolink



Radio Configuration  Step 2 (blok biru menandakan settingan yang sudah dilakukan, pastikan tidak salah setting)



> OK



Enabling Quality of Experience for Everyone



Guide of Commissioning iPasolink



AMR / Radio Mapping Configuration  Step 1



Equipment setup > AMR/Radio Mapping Configuration > Setup (Perhatikan di slot berapa modem yang akan di konfigurasi caranya dengan melihat SET POSITION, next jika akan setting konfigurasi modem pada slot selanjutnya ) Standar Adaptive Modulation Radio (AMR) pilih Non Operation



Enabling Quality of Experience for Everyone



Guide of Commissioning iPasolink



AMR / Radio Mapping Configuration  Step 2 Setting E1 Mapping / STM-1 Mapping sesuai kebutuhan



> NEXT > OK



Enabling Quality of Experience for Everyone



Guide of Commissioning iPasolink



IP Address Setting



Equipment setup > Network Management Configuration > General Setting > Setup (Setting IP Address, Subnet Mask dan Default Gateway sesuai alokasi) Koordinasi dengan Service Desk untuk alokasi IP



Enabling Quality of Experience for Everyone



Guide of Commissioning iPasolink



Auto Discovery Setting Equipment setup > Network Management Configuration > General Setting (Detail) > Setup (Setting Auto Discovery LLDP Mode Setting Standar Proprietary MAC)



4 1



2 3



Setting discovery usage port NMS dan port Back to Back IDU dari Not Used menjadi Used dan LLDP Mode Standard menjadi Proprietary MAC



Untuk port yang mengarah ke RBS, MSTP, Node B dan DMR, Discovery Usage tetap di setting Not Used



Enabling Quality of Experience for Everyone



Guide of Commissioning iPasolink



Modem Port Setting



Provisioning > Modem Function Setting > Modem Port Setting Pilih Modem Slot sesuai yang di install dan setting label pada Port Name



Standar Modem Port Name Format : Site ID (yang sedang di install) To Site ID Opposite (lawannya)



Contoh : 3214 To 2341



Enabling Quality of Experience for Everyone



Guide of Commissioning iPasolink



Modem Port Setting Format Baru (menggunakan tower index) Note : Acuannya berdasarkan link budget (LB) jika di LB sudah menggunakan tower indeks, maka harus di setting menggunakan format baru (tower indeks)



Format : To_TOWER INDEX_ HS/SD/2+0/4+0_DIAMETER ANT Example : To SUM-BE-MNA-0158_1+1HS_0.6m



Tower Index



Enabling Quality of Experience for Everyone



Config Diameter Antenna



Guide of Commissioning iPasolink



Radio Switch Setting (if config 1+1)



Provisioning > Modem Function Setting > Radio Switch Setting Pilih Modem Slot sesuai yang di install dan setting seperti di bawah TX SW Priority



: No.1



TX SW Lock-in Usage



: Not Used



RX SW Priority



: No.1



RX SW Condition Early Warning



: Included Early Warning



Enabling Quality of Experience for Everyone



Guide of Commissioning iPasolink



TX Power Setting



Provisioning > Modem Function Setting > TX Power Setting Pilih Modem Slot sesuai yang di install dan setting TX Power dan RX Treshold sesuai alokasi Alokasi Tx Power dan Rx Treshold lihat pada Link Budget (LB)



Enabling Quality of Experience for Everyone



Guide of Commissioning iPasolink



TX Power, RX Threshold (Link Budget) Contoh TX Power&RX Threshold pada LB



Enabling Quality of Experience for Everyone



Guide of Commissioning iPasolink



Ethernet Port Setting



Provisioning > ETH Function Setting > ETH Port Setting Pilih Port yang akan digunakan, setting Enable dan setting Port Name sesuai standar



Standar ETH Port Name 1. To iPaso Format : To PortNE IduIndeks IP Contoh : To Port3 i400-3 192.168.168.4 2. To non-iPaso equipment Format : To(spasi)Jenis Perangkat*(spasi)Equipment*/ Slot*/Port*(spasi)IP NMS* Contoh : To MLTN 1/8/4 10.49.35.99 Enabling Quality of Experience for Everyone



Guide of Commissioning iPasolink



VLAN Setting  Step 1 (Creat VLAN)



Provisioning > ETH Function Setting > VLAN Setting 1. 2. 3. 4.



Pilih VLAN List Add VLAN ID Input VLAN ID & VLAN Service Name OK



Enabling Quality of Experience for Everyone



Guide of Commissioning iPasolink



VLAN Setting  Step 2 (VLAN Setting)



Provisioning > ETH Function Setting > VLAN Setting 1. Pilih VLAN Setting 2. Pilih Port yang akan dilewati VLAN



Enabling Quality of Experience for Everyone



Guide of Commissioning iPasolink



VLAN Setting 3. 4. 5.



Pada Port Type Pilih Trunk Pilih VLAN yang akan digunakan lalu klik pada kolom Enable OK



Enabling Quality of Experience for Everyone



Guide of Commissioning iPasolink



QOS / Classification Setting Setting QoS Classify & Port Setting sesuai standar yang berlaku



Enabling Quality of Experience for Everyone



Guide of Commissioning iPasolink



E1 Cross Connect Setting Provisioning > E1/STM-1/Cross Connect Setting > Cross Connect Setting 1. Pilih Add 2. Input Service No 3. Input Service Name 4. Pilih Connect Type : E1 5. Pilih AMR Linkage pada Edge A yang akan di cross connect ke AMR Linkage pada Edge B 6. Pilih channel E1 yang akan di cross connect pada masing-masing Edge 7. OK



Enabling Quality of Experience for Everyone



Guide of Commissioning iPasolink



E1 Cross Connect Setting Provisioning > E1/STM-1/Cross Connect Setting > E1 Port Setting 1. Pilih Modify 2. Pilih Used pada channel E1 yang akan digunakan 3. Input Label pada Port Name 4. OK



Format Label : to (spasi) BTS (spasi) Site ID* (spasi) Type BTS (UL/OL)* Contoh: to BTS 3503 UL Enabling Quality of Experience for Everyone



Guide of Commissioning iPasolink



Equipment Clock Setting Case Sample (1)  Basic iPaso Radio Link Connection



Basic Clock setting without E1 interface RNC



iPaso ODU



iPaso ODU



iPaso ODU



1+1



iPaso ODU



1+1



MD1/2



MD1/2 MD3/4



MD1/2 MD3/4



IDU



IDU



IDU



Master



Slave Source1 Modem1 Source2 Modem2



iPaso ODU



MD1/2



iPaso ODU 1+1



iPaso ODU 1+0



iPaso ODU



MD3 IDU



Master



iPaso ODU



1+1



MD3/4 IDU



iPaso ODU 1+0



MD5



IDU



iPaso ODU



1+0



MD7 MD8



1+0



IDU



Slave Modem7



IDU



Slave Modem3



Slave Modem1



iPaso ODU



iPaso ODU



iPaso ODU



MD5 MD6



Node-B



Slave Source1 Modem3 Source2 Modem4



iPaso ODU



MD3 MD5



IDU



Slave Source1 Modem1 Source2 Modem2



Master



iPaso ODU



Slave Source1 Modem1 Source2 Modem2



iPaso ODU



MD1/2 MD3



IDU



Enabling Quality of Experience for Everyone



iPaso ODU



1+0



IDU



Slave Modem5



Node-B



MD1 IDU



Slave Modem1



Node-B



Guide of Commissioning iPasolink



Equipment Clock Setting Case Sample (2)  Nodal iPaso Radio Link Connection



Clock setting of Nodal connection without E1 interface RNC iPaso ODU



iPaso ODU



iPaso ODU



iPaso ODU



iPaso ODU



1+1



1+1



MD1/2MD3/4



MD1/2 MD3/4



IDU



iPaso ODU 1+1



MD3/4



IDU



Slave Slave Source1 Modem1 Source1 Modem1 Source2 Modem2 Source2 Modem2



iPaso ODU



iPaso ODU



iPaso ODU



MD1/2MD3/4 MD5/6 MD7/8 IDU



Master Enabling Quality of Experience for Everyone



iPaso ODU



iPaso ODU



1+1



MD3/4 MD5



iPaso ODU 1+0



IDU



Slave Source1 Modem3 Source2 Modem4



Node-B



IDU



Slave Source1 Modem3 Source2 Modem4



iPaso ODU



MD7 MD9



iPaso ODU 1+0



MD3



IDU



IDU



Slave Modem7



Slave Modem3



Node-B



Guide of Commissioning iPasolink



Equipment Clock Setting Case Sample (3)  Back to Back iPaso Radio Link Connection



Clock setting case with back to back connection RNC iPaso ODU



MD1/2



iPaso ODU 1+1



MD1/2



IDU



Master



iPaso ODU



IDU



Slave Source1 Modem1 Source2 Modem2



MD5/6



iPaso ODU 1+1



MD5/6



IDU



IDU



Node-B



Slave Source1 Modem5 Source2 Modem6



Master



In case of Back to Back connection; Installed two iPaso at Same Site and connected by cable iPaso ODU



MD7/8 IDU



Master Enabling Quality of Experience for Everyone



iPaso ODU 1+1



iPaso ODU



MD9/10



MD3



IDU



IDU



Slave Source1 Modem9 Source2 Modem10



Master



iPaso ODU 1+0



MD4 IDU



Slave Modem4



Node-B



Guide of Commissioning iPasolink



Equipment Clock Setting Case Sample (4)  Usage E1 Clock interface iPaso Radio Link Connection



Clock setting with usage E1 interface RNC iPaso ODU



MD1/2



iPaso ODU 1+1



MD1/2 MD3/4



IDU



Slave E1 No.x



MD3/4 IDU



Receiving synchronization signal from BSC by E1 interface



Slave E1 No.x



iPaso ODU 1+1



1+1



iPaso ODU 1+1



MD1/2



IDU



Slave Source1 Modem1 Source2 Modem2 iPaso ODU



iPaso ODU



MD3/4 MD5/6



IDU



iPaso ODU



BSC



iPaso ODU



iPaso ODU



MD3/4 MD7



Slave Source1 Modem3 Source2 Modem4 iPaso ODU



1+0



IDU



Slave Source1 Modem3 Source2 Modem4



IDU



iPaso ODU



MD7 MD9



Slave Source1 Modem1 Source2 Modem2 BTS



iPaso ODU 1+0



IDU



Slave Modem7



Node-B



MD1 IDU



Node-B



Slave Modem1



BTS Enabling Quality of Experience for Everyone



Guide of Commissioning iPasolink



Equipment Clock Setting Provisioning > Equipment Clock/Synchronization Setting > Equipment Clock Setting Jika Master



Enabling Quality of Experience for Everyone



1. Pilih Modify 2. Equipment CLK Mode pilih Master 3. Clock Source Selective Mode pilih PL Mode



Guide of Commissioning iPasolink



Equipment Clock Setting Provisioning > Equipment Clock/Synchronization Setting > Equipment Clock Setting Jika Slave



1. Pilih Modify 2. Equipment CLK Mode pilih Slave 3. Clock Source Selective Mode pilih PL Mode 4. Pada Timing Source pilih Line CLK (Modem) 5. Pilih Slot yang mengarah ke IDU Master pada kolom Slot 6. Piority Leve pilih 1



Enabling Quality of Experience for Everyone



Guide of Commissioning iPasolink



Check Rx Signal Level Metering > Current Metering  Pastikan RSL aktual sudah sesuai dengan alokasi yang diminta pada LB  Pastikan nilai BER 0.0E-10



Enabling Quality of Experience for Everyone



Guide of Commissioning iPasolink



RSL Sample (Link Budget) Contoh RX Signal Level pada LB



Apabila menggunakan frekuensi 7-8 GHz, maka toleransinya -3 dBm; Apabila menggunakan frekuensi 11-23 GHz, maka toleransinya -1 dBm.



Enabling Quality of Experience for Everyone



Guide of Commissioning iPasolink



Date / Time Setting Equipment Utility > Date / Time Setting Pilih Modify  Setting Date / Time sesuai aktual



Enabling Quality of Experience for Everyone



Guide of Commissioning iPasolink



Setting SAPMFtp User Account / Security Setting > User Account Management Pilih Add User Setting seperti dibawah : User Name



: SAPMFtp



Group Name



: Operator



Security Level



: AuthPriv



Auth Algorithm



: MD5



Priv Algorithm



: DES



Password



: scientis



Enabling Quality of Experience for Everyone



Guide of Commissioning iPasolink



Setting SNMP & FTP User Account / Security Setting > Security Management > Service Status Setting SNMP  pilih No 1 pada SNMP Community Setting seperti dibawah :



Enabling Quality of Experience for Everyone



Guide of Commissioning iPasolink



Setting SNMP & FTP User Account / Security Setting > Security Management > Service Status Setting FTP  klik Setting seperti dibawah :



Enabling Quality of Experience for Everyone



Guide of Commissioning iPasolink



Check Interference Maintenance Control > MODEM Maintenance Control Melihat indikasi interference: Di site lawan (NE) pilih On pada TX Mute Control; lalu lihat hasil RsL yang di dapat (harus dibawah -85 dBm) Apabila RX level masih di atas -85 dB, maka ada indikasi interference (cari frekuensi legal yang lain) Kemudian kembalikan TX Mute Control ke posisi Off lagi



Enabling Quality of Experience for Everyone



Guide of Commissioning iPasolink



Check Alarm & Log Current Status  Check alarm pada Active Alarm dan refresh  Chek log pada Event Log  Pastikan tidak ada alarm (tampilan IDU berwarna hijau jika clear alarm)



Enabling Quality of Experience for Everyone



Guide of Commissioning iPasolink



Check PMON / RMON Report PMON / RMON Report  Pastikan MODEM PMON Report dan E1 PMON Report tidak counting error (nilainya 0)



Enabling Quality of Experience for Everyone



Guide of Commissioning iPasolink



Check Radio Capacity Inventory > S/W License Information  Pastikan Radio Capacity sudah sesuai dengan kapasitas yang dibutuhkan agar radio bisa di konfigurasi sesuai standar  Minimal Radio Capacity 150 Mbps (tergantung dengan kebutuhan project)



Enabling Quality of Experience for Everyone



Guide of Commissioning iPasolink



Cara Inject License S/W License Setup > Import License Key Pilih Setup Browse file license yang akan di inject Lalu OK



Enabling Quality of Experience for Everyone



New ALITA “Smart Building”



www.alita.id Enabling Quality of Experience for Everyone



Tambahkan gedung alita



Jl. Muara Dalam Kel. Tanjung Barat, Kec. Jagakarsa Jakarta Selatan 12530 www.alita-indonesia.com Phone Fax



Enabling Quality of Experience for Everyone



: +62 21 29406750 : +62 21 29406751